KITOZER
KITOZER

KITOZER Fire Rated Cable Trunking: 150x100mm

Product Overview

The KITOZER 150x100mm fire-rated cable trunking is engineered to preserve circuit integrity during a fire by containing fire, smoke, and hot gases within the duct. The trunking is fabricated from cold-rolled steel sheet lined with intumescent fire-resistant boards and sealed with fire-resistant gaskets. The duct maintains circuit integrity for 60, 90, or 120 minutes depending on the rating, allowing emergency lighting, fire alarm, and smoke extraction systems to continue operating. Factory-made elbows, tees, and reducers are available to match the straight section, and all joints are supplied with fire-stop compound.

Technical Specifications

Size: 150 mm wide by 100 mm high. Material: steel sheet with intumescent lining. Fire rating: E30, E60, E90, or E120 per EN 1363. Standard length: 3 meters. Cover: bolted with steel screws. Gasket: ceramic fiber, intumescent. Surface: red epoxy primer or painted to order. Accessories: elbow, tee, cross, reducer, end plate. Standards: EN 1363, IEC 61537, CE. Brand: KITOZER. Warranty: 20 years.

Application Scenarios

Fire-rated trunking is required in buildings where emergency circuits must remain functional during evacuation: high-rise offices, hospitals, shopping malls, airports, railway stations, tunnels, and industrial plants. It is used for fire alarm loops, emergency lighting circuits, smoke extractor power, and fire pump control cables. The trunking is routed along escape routes and through fire-rated walls and floors, with every penetration sealed. Because the duct itself maintains integrity, the contained fire-rated cables can perform to their rated survival time without additional protection.

Advantages and Benefits

A fire-rated trunking system simplifies compliance, because the entire assembly is tested and certified rather than relying on field-built firestopping. The intumescent lining expands when heated, sealing any gaps and preventing flame spread along the duct. The bolted cover ensures no piece pops open in a fire. Factory-fabricated fittings remove the risk of on-site construction errors. The system supports circuit integrity cables from multiple manufacturers, giving designers flexibility. A certified fire duct also reduces the burden of demonstrating fire safety during building approval.

Installation and Maintenance Recommendations

Install the trunking strictly according to the certified installation manual, including support spacing, joint torque, and sealant application. Use only the manufacturer-approved fire-stop compound at every joint and penetration. Do not drill or modify sections on site; order custom sizes from the factory. Label every section with the fire rating so inspectors can verify the installation. Do not install non-fire-rated cables inside the fire-rated duct, because they can contribute fuel load and invalidate the certification. Inspect the trunking annually, checking that bolts are tight and gaskets are intact, and reseal any joint that shows signs of cracking.

Every unit leaves the factory after a 100 percent function test, including a full load test at rated current, insulation resistance check, and communication port verification. Each chassis is visually inspected for finish quality and label legibility. A serial number plate records the production date, test result, and calibration reference, so the unit can be traced throughout its service life. KITOZER maintains a factory stock of common units and fittings for short lead-time orders, and larger projects are scheduled against a confirmed production plan. Standard export packing uses a double-wall carton with foam corners, and pallet packing is available for sea freight. The product is designed for disassembly and recycling at end of life, with clearly marked material types on the chassis.

Technical support is available by email and during business hours in the China time zone, with response within one working day. Installation guides, datasheets, CAD drawings, and declaration of conformity are provided on request for every order. KITOZER can also supply customized variants, including different outlet layouts, longer input cords, special colors, or OEM branding, subject to a minimum order quantity. The product family is designed to be compatible with accessories and mounting hardware from the same KITOZER range, so a single supplier can deliver the complete cable management or power distribution system for a project. After installation, KITOZER recommends keeping a small stock of spare parts on site, such as connectors, fuses, and mounting brackets, so routine repairs do not require long lead times.

KITOZER treats every order as a partnership rather than a single transaction. The sales engineering team works with the customer during design to confirm ratings, mounting options, and routing, so the delivered product matches the site conditions. During production, regular photo updates keep the buyer informed, and the finished goods are packed and labeled according to the project shipping mark. Documentation included with each shipment contains the packing list, test report, and certificate of conformity. For export orders, KITOZER handles export packing, container loading, and coordination with the forwarder, and can provide the required commercial invoice and packing list for customs clearance. After delivery, the local distributor or the factory itself provides commissioning guidance by video call, and remains available for technical questions during the first year of operation. This end-to-end support is why customers return to KITOZER for repeat projects across different sites and regions.

Price

From $85 per 3-meter length including fire sealant. Contact KITOZER for certified drawings and test reports for your project approval.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com