Table of Contents
ToggleProduct Overview
The KITOZER 75kW fire water pump control cabinet is a dedicated motor starter and protection unit for fire pumps in commercial and industrial fire protection systems. It provides star-delta reduced-voltage starting to limit inrush current, protects the motor against overload and phase loss, and accepts start signals from the fire alarm panel, pressure switch, and manual pushbutton. The cabinet is built to fire-rated standards and includes a mechanical interlock between the mains and star-delta contactors to prevent phase-to-phase short circuits during transition. Every unit is factory-tested under simulated motor load before shipment.
Working Principle
Under standby, the control power transformer energizes the HMI and the pilot relay logic. When a start command arrives from the fire alarm panel, pressure switch, or local pushbutton, the control logic energizes the mains contactor and the star contactor simultaneously, connecting the motor windings in star for reduced-voltage starting. After a preset transition time, typically 8 to 10 seconds, the star contactor opens and the delta contactor closes, placing the motor windings in full-voltage delta. The electronic overload relay monitors motor current throughout and trips on sustained overcurrent or phase loss. A stop command opens all contactors.
Technical Specifications
Suitable motor: 75kW three phase 380V, rated current about 135A. Starting method: star-delta, transition time adjustable 3 to 15 seconds. Inrush current: about 3 times rated during star, about 1.5 times rated on delta transition. Input: 380V three phase, 50Hz. Protection: motor overcurrent electronic relay, phase loss, overvoltage, undervoltage, earth fault, emergency stop. Indicators: HMI with running status, fault code, elapsed runtime, and last-start time. Communication: RS485 Modbus, optional Ethernet. Dry contacts: running, fault, ready, remote start, remote stop. Enclosure IP42 floor standing, powder coated. Compliance GB 27898, GB 50974, CE.
Application Scenarios
The 75kW fire pump control cabinet is installed in pump rooms of high-rise towers, large shopping malls, underground parking garages, and industrial plants. It controls the main sprinkler pump or hydrant pump that supplies pressurized water to the building fire protection network. It pairs with a pressure switch on the discharge header, a jockey pump controller for small leaks, and the fire alarm panel for automatic start on sprinkler head activation or manual pull station. It is also used as the standby electric pump controller in sites where a diesel engine-driven pump is the duty unit.
Advantages and Features
KITOZER fire pump control cabinets include a built-in pilot duty relay that isolates the weak fire alarm panel signal from the heavy motor control circuit. The HMI logs every start and stop event with timestamp and motor current, providing a maintenance record. A manual hand-off-auto switch allows technicians to test the pump locally. The cabinet includes a dry-contact output to a remote annunciator panel showing running, fault, and power status. Mechanical interlocks prevent simultaneous energization of incompatible contactor combinations. A phase-reversal relay ensures the pump rotates in the correct direction.
Options and Accessories
Optional items include an Ethernet communication card, a stainless steel enclosure for damp pump rooms, a remote hand-off-auto station mounted near the pump, and a seismic bracing kit. A star-delta to soft-starter upgrade is available on request. The cabinet can be pre-wired for duty-standby alternation with a second pump. Custom paint, customer branding, and bilingual labels are supported. A remote annunciator panel for the fire command room is available.
Installation and Maintenance
Mount the cabinet adjacent to the pump in a clean, dry room with ambient temperature between 5 and 40 degrees Celsius. Connect the upstream breaker sized at 1.25 times rated motor current. Verify motor rotation before commissioning. Set the star-delta transition time based on pump inertia, typically 8 to 10 seconds. Maintenance: quarterly visual inspection, contactor contact check, and terminal torque; annual motor insulation test, current sensor calibration, and contactor inspection; every five years replace contactor contacts and auxiliary switches.
Warranty and Factory Testing
Every KITOZER unit undergoes a full-load burn-in test for 4 hours before shipment, with a printed test report covering input voltage, output voltage, transfer time, and protection relay operation. The power electronics carry a 5-year warranty against manufacturing defects, while the battery bank carries a 3-year replacement warranty. Spare parts are available from stock in Guangzhou, and on-site commissioning support can be arranged for large projects.
Price
From $3,480 per cabinet including 75kW star-delta starter. Contact +86 13922289957 for project pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com