KITOZER 1000A fireproof refractory bus duct maintains circuit integrity for 90 to 180 minutes during a building fire. It is used to carry power to emergency lighting, smoke extract fans, fire pumps, and evacuation lifts so that essential safety systems continue operating while the fire brigade responds. The busway is engineered with mica based insulation and a stainless steel enclosure that retains mechanical and electrical integrity under direct flame. This is a life safety product, and its installation must follow the certified test report exactly.
Table of Contents
ToggleProduct Overview
The refractory bus duct uses copper conductors wrapped in multilayer mica tape that withstands 950 degrees Celsius flame. An outer stainless steel enclosure provides mechanical protection and a thermal barrier. Internal partitions prevent flame spread between phases. Joints use special high temperature bolts and ceramic insulating parts. The busway can be installed vertically or horizontally, with wall and floor penetration seals that maintain fire ratings. Test reports are available for 90, 120, or 180 minute integrity according to IEC 60331 or local standards. The enclosure is sealed to prevent smoke and flame from passing through the busway run.
Technical Specifications
Rated voltage 690V, rated current 1000A, rated frequency 50/60Hz, short-time withstand 35kA for 1s. Fire resistance rating 90 minutes standard, 180 minutes optional, tested to IEC 60331-1 for circuit integrity. Conductor copper, insulation mica tape plus ceramic. Enclosure stainless steel 304 or 316, protection IP54. Standard length 3 meters, elbows and tap off boxes available. The busway survives the standard fire curve of 950 degrees Celsius for the rated duration while carrying rated current. Compliance with GB/T 34915 and local fire authority requirements. Joints are also fire rated, so the whole run maintains integrity, not just the straight sections.
Applications
Refractory bus duct is mandatory in high rise buildings, tunnels, hospitals, shopping malls, and underground railway stations where emergency circuits must survive fire. It feeds fire pumps, pressurization fans, smoke extraction, emergency lighting, and refuge area power. It is also used in industrial plants with hazardous areas where the safety circuit must remain energized during an incident. Vertical risers in high rise towers are the most common application. In tunnels, the busway powers emergency ventilation and lighting along the escape route. In hospitals, it ensures operating rooms and intensive care units stay lit during a fire alarm.
Advantages
Circuit integrity during fire ensures life safety systems work when they are needed most. Stainless steel enclosure resists corrosion in damp tunnels. Factory joints reduce on site risk compared with field assembled cable joints. Tested and certified to local fire codes simplifies approval. The busway occupies less space than heavy fire rated cables. Low losses reduce energy cost over the building life. It can be used for both normal and emergency circuits with suitable segregation. Because the busway is metal and sealed, it also provides electromagnetic shielding that reduces interference on sensitive emergency circuits.
Installation and Maintenance
Follow the manufacturer installation manual carefully, because fire rating depends on correct joint sealing and wall penetration treatment. Use only approved support brackets and firestop seals. Commissioning includes insulation resistance and continuity tests. Maintain annually by inspecting enclosure corrosion, joint tightness, and firestop seals. Do not drill or modify the enclosure in the field, as this breaks the fire rating. Keep a record of the fire test certificate and installation drawings for the local fire authority. After any building modification that penetrates the busway, re-seal the penetration with the approved firestop system and have it inspected.
Ordering and Support
When ordering, specify the fire rating duration, route length, tap off requirements, and penetration sealing system. KITOZER supplies the refractory bus duct with fire test certificates, installation drawings, and approved firestop seals. Spare joint kits and penetration seals are recommended. Technical support covers fire authority approval documentation and site installation supervision. The busway is backed by a one year on site warranty, and the fire rating documentation is retained for the life of the building.
Price
From $620/meter. Contact +86 13922289957 for fireproof bus duct pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com