Table of Contents
ToggleProduct Overview
The KITOZER FK-5-1-12 (Novec 1230) clean agent fire suppression system uses the next-generation fluoroketone extinguishant that suppresses fires by rapid heat absorption while offering zero ozone depletion potential and an atmospheric lifetime of just 5 days. The liquid agent is stored in 40 or 100 liter cylinders at 2.5 MPa nitrogen super-pressurization, and discharges as a gas in under 10 seconds. FK-5-1-12 is selected for high-value occupied spaces where the user wants the clean-room benefits of gas suppression without the greenhouse impact of older halocarbon agents.
Technical Specifications
Cylinder options 40L, 70L, 100L, storage pressure 2.5 MPa nitrogen at 20 degrees Celsius, agent FK-5-1-12 liquid, cylinder material 34CrMo4 seamless steel, valve brass with solenoid and manual actuator, pressure gauge 0 to 6 MPa, safety rupture disc, discharge time under 10 seconds, design concentration 4.2% for Class A, 5.9% for Class B, nozzle DN15 to DN25 calibrated, CCCF certified, optional UL listing. Operating temperature 0 to 50 degrees Celsius, agent boiling point 49 degrees Celsius.
Application Scenarios
FK-5-1-12 is deployed in data centers, server rooms, UPS and battery rooms, electrical switchgear, control rooms, museums, libraries, archives, telecom shelters, and semiconductor manufacturing areas. It is particularly favored in green building projects and corporate headquarters that must meet strict sustainability targets, because the agent has a global warming potential of about 1 compared with thousands for legacy halocarbons. The system can be configured as single-zone direct flood or multi-zone with selector valves, and KITOZER supplies the full package including cylinders, nozzles, piping, panel, and detectors.
Key Advantages
FK-5-1-12 is safe for occupied spaces at design concentration, with no post-discharge evacuation delay. The liquid agent has high density, so fewer cylinders are needed than for inert gas systems, reducing cylinder room footprint. The agent leaves no residue and is non-conductive, so sensitive electronics require no cleanup after discharge. The 5-day atmospheric lifetime means the system meets the most stringent environmental approvals, and KITOZER supplies all documentation required for green building certification.
Installation and Maintenance Recommendations
Install cylinders in a dedicated room anchored to steel racks, with temperature controlled between 0 and 50 degrees Celsius because the agent vapor pressure is sensitive to temperature. Pipe the discharge network using seamless steel pipe with threaded or grooved joints rated for 2.5 MPa. Check cylinder pressure monthly and weigh cylinders semiannually; if agent mass drops more than 1%, refill the cylinder. Inspect nozzles quarterly for blockages, and test the fire alarm release circuit annually with the main cylinder solenoids isolated. After a discharge, ventilate the room and inspect nozzles and piping before refilling.
Price
From $3,450 per 100L cylinder filled with FK-5-1-12. Contact +86 13922289957 for Novec system pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com