Table of Contents
ToggleProduct Overview
The KITOZER 70 liter FM200 (HFC-227ea) cylinder is a high-pressure seamless steel storage container designed to hold clean gaseous extinguishing agent for total flood fire suppression systems in data centers, electrical rooms, switchgear rooms, museums, libraries, and process control cabinets. At 4.2 MPa storage pressure at 20 degrees Celsius, the 70 liter cylinder can hold approximately 86 kg of FM200 agent, enough to protect a typical 60 cubic meter room at 8% design concentration. The cylinder ships with valve, siphon tube, pressure gauge, solenoid actuator, and safety rupture disc, ready to be mounted on a bottle rack and piped to nozzles.
FM200 is a colorless, odorless, electrically non-conductive gas that suppresses fire by interrupting the chemical reaction in the flame, rather than by smothering or cooling. It discharges in under 10 seconds, well below the 10-second limit required by most fire codes, and leaves no residue on equipment. Because the agent is stored as a liquid and vaporizes on discharge, the cylinder is pressurized with nitrogen to 4.2 MPa, which provides the driving force to push the liquid through the piping and nozzles. KITOZER supplies the cylinder either empty or pre-filled with FM200, with a filling certificate traceable to the agent manufacturer.
Technical Specifications
Water volume 70 liters, working pressure 4.2 MPa at 20 degrees Celsius, hydrostatic test pressure 6.3 MPa, cylinder material 34CrMo4 seamless steel, outside diameter 279 mm, wall thickness 9.5 mm, overall height 1280 mm, net weight empty 68 kg, agent capacity FM200 up to 86 kg, valve brass forged DN25, solenoid actuator 24V DC, manual actuator lever, pressure gauge 0 to 10 MPa, safety rupture disc burst at 6.8 plus or minus 0.34 MPa, dip tube stainless steel, CCCF certified, ISO 9809, optional UL listing.
The cylinder is drawn from a seamless steel tube, heat treated to a minimum tensile strength of 800 MPa, and shot blasted externally before painting. The valve is a brass forged body with a 24V DC solenoid pilot that opens the main valve when energized by the fire alarm panel. A manual lever allows local release by pulling a cable, and a pressure gauge shows the internal nitrogen pressure. The safety rupture disc is a graphite disc that bursts if the cylinder is exposed to fire, venting the agent safely through a dedicated vent pipe. The dip tube reaches the bottom of the cylinder, so liquid agent is pushed out during discharge rather than just nitrogen gas.
Application Scenarios
This FM200 cylinder protects enclosed spaces where water sprinklers would cause unacceptable collateral damage, including UPS rooms, battery rooms, server racks, electrical switchgear, control rooms, telecommunications shelters, library vaults, museum display halls, and process control panels. Multiple cylinders can be manifolded together for larger rooms, and selector valves can split one bank of cylinders to protect several zones. Typical single-cylinder use covers server rooms of 50 to 80 cubic meters, cable tunnels, and small transformer rooms.
For data centers, a typical 200 square meter server hall requires 4 to 6 cylinders manifolded together, with selector valves routing the agent to the correct zone. For battery rooms, the agent concentration is increased to 9% to handle lithium-ion thermal runaway. For museums and libraries, FM200 is preferred because it does not leave residue on paper, paintings, or artifacts. For offshore control rooms, the cylinders are mounted on anti-vibration racks to survive ship motion. KITOZER provides full system design, including hydraulic calculation, nozzle layout, and cylinder sizing, as part of the supply package.
Key Advantages
FM200 discharges in under 10 seconds and suppresses fires by heat absorption and radical interruption, leaving no residue and no secondary water damage. The seamless steel cylinder is manufactured to ISO 9809 and is internationally transportable under UN pressure vessel regulations. The integrated solenoid and manual actuator allows both automatic release from the fire alarm panel and local manual release by the building fire team. KITOZER ships each cylinder with a factory filling certificate, pressure test report, and material traceability, simplifying project handover to the local fire authority.
The 4.2 MPa storage pressure allows the cylinder to be located up to 20 meters away from the protected room, which is useful when the cylinder room cannot be inside the protected space. The valve design includes a built-in filter that prevents pipe debris from entering the solenoid pilot, reducing false failures. The pressure gauge is visible from the front of the rack, so maintenance staff can check cylinder pressure without bending down. KITOZER also supplies a matched fire alarm control panel with two-stage detection, pre-discharge alarm, and release circuit, completing the system from one supplier.
Installation and Maintenance Recommendations
Mount cylinders upright on a welded steel rack, anchored to the floor with M12 bolts, and keep the rack in a ventilated, locked room with temperature between 0 and 50 degrees Celsius. Pipe the discharge to nozzles using seamless steel pipe threaded or flanged, and slope the pipe toward the nozzle so any condensation drains freely. Check cylinder pressure gauge monthly and compare with the reference needle on the gauge; if pressure drops more than 10%, the cylinder must be removed for refilling. Weigh cylinders semiannually to confirm agent mass, and replace the solenoid actuator every 10 years.
Because FM200 is stored as a liquid, pressure readings alone do not confirm agent mass, because a nitrogen leak can drop pressure without losing agent. The semiannual weight check is therefore the primary verification. Keep the cylinder room door locked, and post a warning sign that accidental discharge can be fatal in a confined space. Before any maintenance work inside the protected room, isolate the release circuit with a maintenance key switch. After any discharge, ventilate the room for 15 minutes before re-entry, and inspect nozzles and piping before refilling. KITOZER provides a 10-year cylinder warranty and a 2-year valve warranty.
Price
From $1,280 per cylinder filled with FM200. Contact +86 13922289957 for gas suppression cylinder pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com