KITOZER
KITOZER

KITOZER FM200 Cylinder: 70L 4.2MPa Gas Fire Suppression Cylinder

Product Overview

The KITOZER 70 liter FM200 (HFC-227ea) cylinder is a high-pressure seamless steel storage container designed to hold clean gaseous extinguishing agent for total flood fire suppression systems in data centers, electrical rooms, switchgear rooms, museums, libraries, and process control cabinets. At 4.2 MPa storage pressure at 20 degrees Celsius, the 70 liter cylinder can hold approximately 86 kg of FM200 agent, enough to protect a typical 60 cubic meter room at 8% design concentration. The cylinder ships with valve, siphon tube, pressure gauge, solenoid actuator, and safety rupture disc, ready to be mounted on a bottle rack and piped to nozzles.

Technical Specifications

Water volume 70 liters, working pressure 4.2 MPa at 20 degrees Celsius, hydrostatic test pressure 6.3 MPa, cylinder material 34CrMo4 seamless steel, outside diameter 279 mm, wall thickness 9.5 mm, overall height 1280 mm, net weight empty 68 kg, agent capacity FM200 up to 86 kg, valve brass forged DN25, solenoid actuator 24V DC, manual actuator lever, pressure gauge 0 to 10 MPa, safety rupture disc burst at 6.8 plus or minus 0.34 MPa, dip tube stainless steel, CCCF certified, ISO 9809, optional UL listing.

Application Scenarios

This FM200 cylinder protects enclosed spaces where water sprinklers would cause unacceptable collateral damage, including UPS rooms, battery rooms, server racks, electrical switchgear, control rooms, telecommunications shelters, library vaults, museum display halls, and process control panels. Multiple cylinders can be manifolded together for larger rooms, and selector valves can split one bank of cylinders to protect several zones. Typical single-cylinder use covers server rooms of 50 to 80 cubic meters, cable tunnels, and small transformer rooms.

Key Advantages

FM200 discharges in under 10 seconds and suppresses fires by heat absorption and radical interruption, leaving no residue and no secondary water damage. The seamless steel cylinder is manufactured to ISO 9809 and is internationally transportable under UN pressure vessel regulations. The integrated solenoid and manual actuator allows both automatic release from the fire alarm panel and local manual release by the building fire team. KITOZER ships each cylinder with a factory filling certificate, pressure test report, and material traceability, simplifying project handover to the local fire authority.

Installation and Maintenance Recommendations

Mount cylinders upright on a welded steel rack, anchored to the floor with M12 bolts, and keep the rack in a ventilated, locked room with temperature between 0 and 50 degrees Celsius. Pipe the discharge to nozzles using seamless steel pipe threaded or flanged, and slope the pipe toward the nozzle so any condensation drains freely. Check cylinder pressure gauge monthly and compare with the reference needle on the gauge; if pressure drops more than 10%, the cylinder must be removed for refilling. Weigh cylinders semiannually to confirm agent mass, and replace the solenoid actuator every 10 years.

Price

From $1,280 per cylinder filled with FM200. Contact +86 13922289957 for gas suppression cylinder pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top