The KITOZER 300RT free cooling chiller combines a screw compressor refrigeration cycle with an integrated air side free cooling coil. In cold or winter months, ambient air directly cools the glycol loop through the free cooling coil, allowing the compressors to unload or shut down entirely. This dramatically reduces data center PUE and operating cost. The unit is purpose built for outdoor installation in temperate and cold climates where outdoor air temperature drops below 10 C for extended periods.
Table of Contents
ToggleProduct Overview
The free cooling chiller uses a twin screw compressor with R513A low GWP refrigerant. The free cooling section is a copper tube aluminum fin coil in series with the condenser. A motorized three way valve diverts return glycol water through the free cooling coil when ambient conditions permit. The controller automatically stages between 100 percent mechanical cooling, partial free cooling, and 100 percent free cooling based on ambient and return water temperatures. EC fans modulate to match the required heat rejection.
Technical Specifications
Mechanical cooling capacity 300 RT (1055 kW). Free cooling capacity up to 900 kW at 0 C ambient with 10 C return glycol. Glycol solution 30 percent ethylene glycol. Evaporator water flow 180 m3 per h. Power supply 380 V 50 Hz. Compressor power 195 kW. Total fan power 15 kW. Operating ambient range minus 25 C to 45 C. Sound level 78 dB(A) at 10 m. Weight 9500 kg. CE certified, 5 year compressor warranty.
Application Scenarios
This chiller is designed for data center central plants, telecom base station cooling, and industrial process cooling in regions with cold winters. It replaces conventional air cooled chillers and provides substantial energy savings during heating seasons. Typical payback period is two to four years depending on local climate and electricity price. It is also suitable for hybrid cooling plants where a dry cooler provides winter free cooling and the chiller handles peak summer load.
Advantages and Features
Integrated free cooling eliminates the need for a separate dry cooler and external piping, reducing installation cost and footprint. Automatic staging ensures smooth transition between cooling modes without operator intervention. The EC fans reduce fan energy compared with fixed speed fans. Low ambient operation down to minus 25 C without head pressure control issues. The unit is pre charged and factory tested, with a complete controller and BMS communication ready. Seasonal energy savings can reach 40 percent compared with standard air cooled chillers.
Installation and Maintenance
Install the unit on a level concrete pad with enough clearance for air discharge and coil cleaning. Use flexible connections on water pipes. Verify glycol concentration is adequate for the design minimum ambient. Commissioning includes testing three way valve operation, free cooling interlock, and fan VFD response. Semi annual maintenance includes coil cleaning, refrigerant leak check, and electrical terminal inspection. Inspect glycol quality annually and top up with inhibited glycol as needed. Winterize the unit by verifying heater and drain functions.
Price
From $38,500 per unit. Contact KITOZER for climate specific energy saving analysis.