KITOZER Fresh Air Handling Unit 2000 m3/h Heat Recovery

Product Overview

The KITOZER Fresh Air Handling Unit (FAHU) 2000 m3/h with heat recovery is a packaged ventilation system designed to supply filtered, conditioned outdoor air to data centers, server rooms, offices, and industrial control rooms while recovering energy from exhaust air. The unit combines a counter-flow plate heat exchanger, supply and EC fans, G4 and F8 filter banks, optional cooling or heating coils, and an integrated controller with BMS connectivity. At 2000 m3/h, it is sized for 100 to 200 square meter rooms or a single contained cold aisle. The heat recovery core transfers up to 75 percent of exhaust air energy to incoming fresh air, reducing annual heating and cooling costs dramatically compared to bypass ventilation.

Without heat recovery, introducing fresh air to a data center means cooling or heating the entire outdoor air volume from scratch, which wastes chiller and boiler energy. The KITOZER counter-flow plate exchanger transfers both sensible and latent energy, pre-cooling incoming hot humid air in summer and pre-heating cold air in winter. The EC fans modulate speed based on room CO2, occupancy, or static pressure setpoints, so the unit only moves as much air as the room actually needs. KITOZER also provides an optional economy cycle that bypasses the heat exchanger and cooling coil when outdoor air temperature is ideal, bringing in free-cooling fresh air directly. The touchscreen controller displays supply and exhaust temperatures, filter resistance, fan speed, and alarm status in real time.

Technical Specifications

Airflow: 2000 m3/h supply and exhaust. Heat recovery: cross-flow aluminum plate, efficiency up to 75 percent. Fans: EC centrifugal, 0.55 kW each, stepless 0 to 10V. Filters: G4 pre-filter, F8 fine filter, optional H13. Coils: optional hot water, chilled water, or DX direct expansion. Casing: 25mm insulated galvanized steel, RAL 7035. External static pressure: 300 Pa supply, 200 Pa exhaust. Noise: 58 dBA at 1 meter. Power: 230V 50Hz, 1.2 kW. Control: touch screen, Modbus RTU/TCP, BMS. Operating ambient: -10 to 45 degrees Celsius. Dimensions: 1500x900x1100mm. Weight: 280 kg. CE, Eurovent, RoHS. KITOZER brand, 2 year warranty.

Applications

The 2000 m3/h FAHU is used in small and medium data centers, server rooms, telecom central offices, office buildings, laboratories, hospital auxiliary rooms, museum galleries, archive repositories, and factory control rooms. It supplies positive-pressure fresh air to prevent infiltration of dusty or humid outdoor air, and the heat recovery ensures energy-efficient ventilation year-round. In data centers, the unit also provides emergency outside-air free cooling when ambient temperature drops below setpoint, reducing chiller runtime. In archives and museums, it controls both humidity and particulate to protect paper and artifacts. The unit also maintains positive room pressure so unconditioned outdoor air does not leak in through door gaps.

Key Advantages

First, 75 percent heat recovery cuts ventilation energy by up to 60 percent. Second, EC fans modulate based on CO2 or occupancy sensors. Third, multi-stage filtration protects IT equipment from dust and humidity. Fourth, integrated BMS allows remote monitoring and scheduling. Fifth, compact wall or floor installation. Sixth, built-in free cooling economy cycle. Seventh, easy filter access from front. Eighth, low noise for office-adjacent rooms. Ninth, the unit also maintains positive room pressure to prevent unconditioned air infiltration. Tenth, the modular design allows future upgrades such as adding a humidifier or UV germicidal light.

Customization Options

KITOZER offers chilled water coil, hot water coil, or DX direct expansion options, humidification and dehumidification modules, enthalpy wheel upgrade, stainless steel casing for corrosive environments, and motorized dampers with BMS control. Custom colors, higher external static pressure for long duct runs, and ATEX-rated fans for explosive atmospheres are available.

Installation and Maintenance

The FAHU should be installed on anti-vibration pads, connected to supply and exhaust ducts with flexible connectors, and wired to BMS. Commissioning includes airflow balancing, filter pressure differential check, and heat exchanger bypass calibration. Maintenance: replace G4 filter every 3 months, F8 every 6 to 12 months, inspect heat exchanger annually for fouling, and lubricate fan bearings. KITOZER supplies replacement filters and coils, backed by a 2-year warranty on the unit.

Warranty and Global Support

KITOZER supplies replacement filters and coils, backed by a 2-year warranty on the unit. Spare filters, EC fan controllers, and sensor probes are held in regional stock for next-day dispatch. KITOZER also offers long-term maintenance contracts covering quarterly filter replacement, annual coil cleaning, and fan bearing lubrication.

Price

From $6,800 per FAHU including heat recovery core and G4/F8 filters. Contact +86 13922289957 for coil and free cooling options.