KITOZER Fresh Air Handling Unit 2000 m3/h Heat Recovery

Product Overview

The KITOZER Fresh Air Handling Unit (FAHU) 2000 m3/h with heat recovery is a packaged ventilation system designed to supply filtered, conditioned outdoor air to data centers, server rooms, offices, and industrial control rooms while recovering energy from exhaust air. The unit combines a counter-flow plate heat exchanger, supply and EC fans, G4 and F8 filter banks, optional cooling or heating coils, and an integrated controller with BMS connectivity. At 2000 m3/h, it is sized for 100 to 200 square meter rooms or a single contained cold aisle. The heat recovery core transfers up to 75 percent of exhaust air energy to incoming fresh air, reducing annual heating and cooling costs dramatically compared to bypass ventilation.

Technical Specifications

Airflow: 2000 m3/h supply and exhaust. Heat recovery: cross-flow aluminum plate, efficiency up to 75 percent. Fans: EC centrifugal, 0.55 kW each, stepless 0 to 10V. Filters: G4 pre-filter, F8 fine filter, optional H13. Coils: optional hot water, chilled water, or DX direct expansion. Casing: 25mm insulated galvanized steel, RAL 7035. External static pressure: 300 Pa supply, 200 Pa exhaust. Noise: 58 dBA at 1 meter. Power: 230V 50Hz, 1.2 kW. Control: touch screen, Modbus RTU/TCP, BMS. Operating ambient: -10 to 45 degrees Celsius. Dimensions: 1500x900x1100mm. Weight: 280 kg. CE, Eurovent, RoHS. KITOZER brand, 2 year warranty.

Applications

The 2000 m3/h FAHU is used in small and medium data centers, server rooms, telecom central offices, office buildings, laboratories, hospital auxiliary rooms, museum galleries, archive repositories, and factory control rooms. It supplies positive-pressure fresh air to prevent infiltration of dusty or humid outdoor air, and the heat recovery ensures energy-efficient ventilation year-round. In data centers, the unit also provides emergency outside-air free cooling when ambient temperature drops below setpoint, reducing chiller runtime.

Key Advantages

First, 75 percent heat recovery cuts ventilation energy by up to 60 percent. Second, EC fans modulate based on CO2 or occupancy sensors. Third, multi-stage filtration protects IT equipment from dust and humidity. Fourth, integrated BMS allows remote monitoring and scheduling. Fifth, compact wall or floor installation. Sixth, built-in free cooling economy cycle. Seventh, easy filter access from front. Eighth, low noise for office-adjacent rooms.

Installation and Maintenance

The FAHU should be installed on anti-vibration pads, connected to supply and exhaust ducts with flexible connectors, and wired to BMS. Commissioning includes airflow balancing, filter pressure differential check, and heat exchanger bypass calibration. Maintenance: replace G4 filter every 3 months, F8 every 6 to 12 months, inspect heat exchanger annually for fouling, and lubricate fan bearings. KITOZER supplies replacement filters and coils.

Price

From $6,800 per FAHU including heat recovery core and G4/F8 filters. Contact +86 13922289957 for coil and free cooling options.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com