Product Overview

The KITOZER FAHU 5000 m3/h is a larger packaged air handling unit designed for medium data halls, commercial buildings, and industrial process rooms requiring substantial fresh air. It integrates a cross-flow heat recovery wheel or plate core, supply and exhaust EC fans, G4 and F8 filtration, a six-row chilled water cooling coil with drain pan, optional heating coil, and a programmable controller. The unit delivers both ventilation and dehumidification in one package, maintaining data hall humidity at 40 to 60 percent RH even in humid climates. At 5000 m3/h, it serves rooms of 300 to 500 square meters or multiple containment aisles.

In tropical and subtropical climates, introducing 5000 m3/h of humid outdoor air without dehumidification would raise data hall RH above 70 percent, risking condensation and corrosion. The KITOZER chilled water coil condenses moisture out of the air stream, while the enthalpy wheel recovers latent energy from the exhaust to reduce reheat load. The PLC controller adjusts valve position based on room humidity and temperature sensors, maintaining setpoints automatically. The controller also schedules the unit based on occupancy calendars, ramping fans down at night and on weekends. KITOZER provides a web dashboard for remote monitoring and alarm notifications via email. The controller also stores historical data for energy audit and LEED reporting.

Technical Specifications

Airflow: 5000 m3/h. Heat recovery: rotary enthalpy wheel, efficiency 70 to 80 percent. Cooling coil: 6-row copper tube aluminum fin, 20 kW at 7/12 degrees Celsius chilled water. Drain pan: stainless steel with insulated slope. Fans: EC plug fans, 1.5 kW each. Filters: G4 + F8 + optional H13. External static: 500 Pa supply. Casing: double-skin 50mm insulated. Power: 400V three phase, 4 kW. Control: PLC with touchscreen, Modbus TCP, BMS. Noise: 62 dBA at 1 meter. Dimensions: 2400x1400x1800mm. Weight: 950 kg. CE, Eurovent. KITOZER brand, 2 year warranty.

Applications

The 5000 m3/h FAHU is used in enterprise data centers, colocation halls, office towers, shopping malls, hotel lobbies, hospital wards, factory assembly halls, museum atriums, and underground parking ventilation. In data centers, it provides outside air free cooling, humidity control, and positive pressure. The chilled water coil ties into the building chiller plant for dehumidification during humid summer months. In pharmaceutical packaging halls, it maintains ISO 8 clean room conditions with positive pressure. The unit also provides winter humidification to prevent static electricity buildup in electronics assembly areas. In data centers, this moisture control also protects IT hardware from dry-air corrosion.

Key Advantages

First, enthalpy wheel recovers both sensible and latent energy. Second, integrated chilled water coil provides dehumidification. Third, EC fans with VFD save 40 percent at part load. Fourth, double-skin casing prevents condensation. Fifth, PLC control with weather logic optimizes free cooling. Sixth, BMS integration. Seventh, modular design allows coil additions. Eighth, low maintenance with accessible filters and drain pan. Ninth, the unit can be configured for 100 percent outside air or recirculation mode. Tenth, the double-skin casing prevents external condensation in humid climates. The unit also supports BMS integration for remote monitoring and scheduling.

Customization Options

KITOZER offers enthalpy wheel or static plate heat recovery, humidification modules, electric or hot water reheat coils, UV germicidal lights, stainless steel drain pans, motorized dampers, and BMS gateways. Custom casing sizes, higher external static pressure, and rooftop weather hoods are available. KITOZER can also supply the unit with a built-in humidification module for dry climates.

Installation and Maintenance

Install on anti-vibration springs, connect chilled water piping with isolation valves and flexible hoses, and drain pan to floor drain. Commission: balance airflow, set enthalpy wheel schedule, verify coil delta T, and test freeze protection. Maintenance: G4 filter quarterly, F8 semi-annual, coil cleaning annually, wheel brush inspection yearly, and belt or motor check. KITOZER provides a maintenance manual and spare parts list, backed by a 2-year warranty.

Warranty and Global Support

KITOZER provides a maintenance manual and spare parts list, backed by a 2-year warranty. Spare filters, fan belts, coil valves, and sensor probes are held in regional stock. KITOZER also offers long-term maintenance contracts covering quarterly filter changes, annual coil cleaning, and enthalpy wheel inspection. Remote commissioning support via video call is included. Spare parts are shipped from regional stock.

Price

From $18,500 per FAHU including enthalpy wheel and chilled water coil. Contact +86 13922289957 for project quotation.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com