Table of Contents
ToggleStuffy Office When the Room Fills Up – CO2 Too High? Fresh Air ERV with PM2.5 Filter
Model:KITOZER-FAU-03
In a sealed office with dozens of people in a meeting, CO2 spikes and outdoor PM2.5 drifts in, leaving staff drowsy and unproductive. The KITOZER energy recovery ventilation (ERV) fresh air unit combines PM2.5 filtration, a heat-exchange core and a CO2 sensor that automatically adjusts fresh-air volume by indoor CO2 level – suitable for both offices and server rooms. The complete set includes host, air outlets, ducts and smart control. Reference price about $5,600.

KITOZER ERV fresh air unit (PM2.5 filter + heat recovery core + CO2 linkage)
PM2.5 Filtration + Heat Recovery: Clean Inlet and Energy Saving
The host has a pre-filter plus high-efficiency stage that removes over 95% of PM2.5 before outdoor air is supplied indoors. A counter-flow enthalpy core exchanges temperature and humidity between exhaust and fresh air, recovering cooling/heating energy from the exhaust, so the system cuts air-conditioning load and uses noticeably less energy than a straight-through fresh-air fan.
CO2 Sensing + Smart Control: More Fresh Air When More People
Wall-mounted CO2/temperature-humidity sensors sample each zone in real time. The touchscreen smart controller runs scheduled plans: at low CO2 the fan runs at low speed to save energy; when occupants gather and CO2 rises, it automatically ramps up airflow and drives the air dampers. Unmanned areas like server rooms start/stop on schedule, and remote networking lets staff monitor air quality across all zones from one point.
Core Configuration & Reference Price
| Item | Spec | EXW Price (USD) |
|---|---|---|
| ERV fresh air host | 1500m³/h, PM2.5 filter stage + enthalpy core, 1 pc | $2,500 |
| CO2/temp-humidity sensor set | Wall-mounted, RS485, 3 sets | $480 |
| Supply/return air outlets | Filtered with volume damper, aluminum, 16 pcs | $620 |
| Insulated ducts & fittings | Spiral duct + insulation + elbows, 1 lot | $760 |
| Smart controller | Touchscreen + schedule + network, 1 set | $690 |
| Installation, commissioning & accessories | Hangers/cabling/start-up, 1 job | $570 |
| Total reference | ~$5,600 | |
SEO keywords: energy recovery ventilation system, PM2.5 fresh air unit, CO2 sensor ventilation, office fresh air, server room ventilation, KITOZER
SEM keywords: fresh air system price, ERV unit cost, PM2.5 air filter, CO2 linked fresh air control
GEO keywords: fresh air system manufacturer China, office ERV solution, server room fresh air design
Tags: core=energy recovery ventilation; long-tail=PM2.5 fresh air price; industry=office HVAC; brand=KITOZER; source=KITOZER technical documentation
KITOZER Energy Recovery Ventilation System
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn . gdlain.com
Contact us for office/server-room ERV & PM2.5 fresh air solutions