The KITOZER front-end and back-end servers are core data security devices for network secure transmission, data protection and server security scenarios. Composed of a front-end server (front access processing unit) and a back-end server (back-end core control unit), they are compatible with network security gateways and optical isolation gateways to form a “2+1” hardware architecture for secure data exchange systems.

The core positioning of the system covers isolated heterogeneous networks, trusted data ferry transmission, intelligent protocol conversion and stealth protection of servers. It enables secure data transmission under physical isolation between the Internet/private networks and classified networks/core business networks, blocks direct external access to core servers, and defends against network attacks such as SQL injection, ransomware and unauthorized overreach access. It is widely deployed in industries with mandatory requirements for data security and network isolation including e-government, finance, energy, public security and courts.

As the “nerve center” for secure cross-network data exchange, the KITOZER front-end & back-end server system breaks the limitation of traditional security devices that “focus on protection but neglect transmission”. It integrates six core capabilities: pre-data processing, security filtering, protocol adaptation, load balancing, log auditing and emergency disaster recovery. It guarantees efficient cross-network data transmission while delivering dual protection via hardware isolation and software encryption, realizing “isolation without business interruption, disconnection without transmission halt”. It serves as a key infrastructure for building multi-layered defense security systems for enterprises.

2. System Composition

The KITOZER front-end & back-end server system adopts a modular, distributed architecture consisting of three major components: hardware units, software units and auxiliary supporting units. Each unit operates independently and collaboratively, supporting flexible capacity expansion and customized configuration to meet low, medium and high security level demands.

2.1 Hardware Units

  • Front-End Server (KITOZER-FE) Deployed at the boundary of untrusted networks (Internet, external networks, private networks), this 19-inch standard rack-mounted device undertakes external network data access, protocol parsing, malicious code scanning, data desensitization, request filtering and load distribution. It acts as the “first security barrier” against external access to core networks and conceals internal network topology and server information.
  • Back-End Server (KITOZER-BE) Deployed at the boundary of trusted networks (internal networks, classified networks, core business zones), this 19-inch standard rack-mounted device receives ferried data from the front-end server, reconstructs protocols, verifies data, manages access permissions, stores logs and forwards business traffic. It interfaces with core servers and business systems to securely receive and process internal network data.
  • Isolation Switch Unit (Optional, KITOZER-ISU) Compatible with one-way optical gateways and two-way network gateways, it adopts an FPGA chip / one-way optical module hardware architecture with no network protocol connections. It only ferries data between front-end and back-end servers in the form of raw data blocks, physically blocking reverse attack paths and ensuring absolute security for cross-network transmission.
  • Supporting Hardware Redundant power modules, high-speed fiber network cards, encryption cards, RAID disk arrays and heat dissipation modules support high availability and stable operation of the system.

2.2 Software Units

  • System Management Software (KITOZER-SM) The core control platform supports device configuration, status monitoring, permission management, policy distribution, log query and alarm management with a visual Web interface compatible with multiple browsers for easy operation.
  • Security Protection Software (KITOZER-SP) Integrates virus scanning engine, intrusion detection engine, data desensitization engine, access control engine and encryption/decryption modules. Customizable security policies block malicious traffic, filter sensitive data and prevent unauthorized access.
  • Data Transmission Software (KITOZER-DT) Supports parsing and conversion of mainstream protocols (HTTP/HTTPS, FTP/SFTP, SMTP, Telnet, SSH, Modbus, etc.) to realize secure transmission of files, databases, streaming media and other data types. It supports resume transmission from breakpoints, transmission encryption and integrity verification.
  • Log Auditing Software (KITOZER-LA) Records full-process logs of data transmission, device operations and security alarms, supporting log export, report generation and traceability analysis to meet compliance requirements for Class III Cybersecurity Classified Protection and classified information evaluation.

2.3 Auxiliary Supporting Units

  • Environmental Monitoring Components Temperature, humidity and voltage monitoring modules that track device operating conditions in real time and trigger alarms for abnormal status.
  • Emergency Disaster Recovery Components Dual-server hot standby modules, data backup modules and emergency switching modules support automatic fault switching and scheduled data backup to guarantee business continuity.
  • Remote Operation & Maintenance Components Remote management, upgrade and fault diagnosis modules enable remote configuration, firmware upgrade and troubleshooting to reduce operation and maintenance costs.

3. System Classification

The KITOZER front-end & back-end server system is categorized along four dimensions: security level, transmission direction, deployment architecture and application scenario, covering all low, medium and high security level requirements for customized deployment across industries.

3.1 Classification by Security Level (Core Classification, Matching Low/Medium/High Configuration Lists)

  • Basic Model (Low Security Level, KITOZER-B Series) Suitable for ordinary office networks, non-classified business networks and small and medium enterprise data transmission scenarios. It delivers basic security protection, supports two-way data transmission with fundamental protocol adaptation to meet basic data isolation and transmission demands.
  • Enhanced Model (Medium Security Level, KITOZER-E Series) Designed for e-government non-classified networks, financial branch offices and non-core business networks of energy enterprises. It strengthens security protection with integrated virus scanning, data desensitization and log auditing, supports dual-server hot standby and complies with Class III Cybersecurity Classified Protection standards.
  • Flagship Model (High Security Level, KITOZER-P Series) Built for classified networks, core business networks, bank headquarters, public security and court core data centers. It adopts dual protection of hardware isolation and software encryption, compatible with one-way optical gateways / two-way network gateways, supports national cryptographic algorithm encryption and full-depth protocol parsing, and features emergency disaster recovery to meet Class IV Cybersecurity Classified Protection and classified information evaluation compliance standards.

3.2 Classification by Transmission Direction

  • One-Way Transmission Model (KITOZER-S Series) Enables one-way data ferry from front-end server to back-end server with no reverse data interaction. Ideal for scenarios where classified networks collect data from external networks to eliminate reverse information leakage risks, mainly deployed with one-way optical gateways.
  • Two-Way Transmission Model (KITOZER-D Series) Supports controllable two-way data exchange between front-end and back-end servers for data interaction between non-classified networks, with bidirectional protocol conversion and security filtering, mainly deployed with two-way network gateways.

3.3 Classification by Deployment Architecture

  • Single-Machine Deployment Model Independent deployment of one front-end server plus one back-end server with simple structure and low cost, applicable to small-scale scenarios with low security level requirements.
  • Dual-Server Hot Standby Model Cluster deployment of primary & standby dual front-end servers and primary & standby dual back-end servers with automatic fault switching to eliminate single points of failure, suitable for medium and large scenarios requiring high availability.
  • Cluster Expansion Model Distributed cluster deployment of multiple front-end and back-end servers supporting load balancing and elastic scaling, built for large data centers and high-concurrency transmission scenarios.

3.4 Classification by Application Scenario

  • Government-Dedicated Model Optimized for data exchange between internal and external e-government networks, supporting government protocol adaptation, sensitive data desensitization and government log auditing.
  • Finance-Dedicated Model Tailored for banks, securities firms and insurance companies, supporting UnionPay message parsing, transaction data encryption, anti-fraud filtering and transaction log traceability.
  • Industrial-Dedicated Model Designed for data exchange between industrial control networks (PLC, SCADA) and office networks, supporting parsing of industrial protocols including Modbus and OPC UA, industrial data filtering and industrial control attack defense.
  • General Model Suitable for small and medium enterprises, ordinary offices and campus networks with basic protocol adaptation, fundamental security protection and low-cost deployment.

4. System Schematic Diagram

4.1 Single-Machine Two-Way Transmission Architecture (Basic / Enhanced Model)

Internet / External Network → Firewall → Front-End Server (KITOZER-FE) → Optional Isolation Switch Unit → Back-End Server (KITOZER-BE) → Core Switch → Internal Network Servers / Business Systems

4.2 Single-Machine One-Way Transmission Architecture (Flagship Model for Classified Scenarios)

External Network / Non-Classified Network → Firewall → Front-End Server (KITOZER-FE) → One-Way Optical Gateway (Isolation Switch Unit) → Back-End Server (KITOZER-BE) → Classified Network Core Servers / Business Systems

4.3 Dual-Server Hot Standby Two-Way Transmission Architecture (Enhanced / Flagship Model for High-Availability Scenarios)

External Network → Load Balancer → Primary / Standby Front-End Servers (KITOZER-FE) → Two-Way Network Gateway → Primary / Standby Back-End Servers (KITOZER-BE) → Core Switch → Internal Network Server Cluster

4.4 Core Data Transmission Principle

  1. External network data undergoes preliminary filtering via the firewall and accesses the front-end server;
  2. The front-end server completes protocol parsing, virus scanning, data desensitization and request filtering to generate trusted data streams;
  3. Trusted data ferries through the isolation switch unit (network gateway / optical gateway) at the hardware level to block reverse connections;
  4. The back-end server receives data and completes protocol reconstruction, data verification, permission matching and log recording;
  5. Compliant data is forwarded to internal core servers / business systems to realize secure transmission;
  6. For two-way scenarios, internal network response data is filtered and encrypted by the back-end server, ferried back to the front-end server through the isolation unit, then forwarded to the external network, with full-process controllability and auditability.

5. Full System Configuration List (KITOZER, Low / Medium / High Classification)

5.1 Low Security Level Configuration List (Basic Model, KITOZER-B Series)

表格

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1Front-End ServerKITOZER-FE-B119-inch 1U rack-mounted; Dual-core 2.0GHz CPU; 4GB DDR4 RAM; 500GB SATA HDD; 2×Gigabit Electrical Ports; Single 300W Power Supply; Protocols: Basic HTTP/FTP; Protection: Basic access control, log recording1SetKITOZERSingle-machine deployment, external network access
2Back-End ServerKITOZER-BE-B1Same hardware specs as FE-B1; Basic permission control, log storage, data forwarding filtering1SetKITOZERSingle-machine deployment, internal network interconnection
3System Management SoftwareKITOZER-SM-BBasic configuration, status monitoring, permission management, log query; Web UI; Supports management of up to 100 devices1SetKITOZERIncludes 1-year free upgrade service
4Security Protection SoftwareKITOZER-SP-BBasic virus scanning, access control, data filtering; Customizable policies; Basic virus database updates1SetKITOZERFundamental security defense
5Supporting CabinetKITOZER-C-12U12U standard cabinet, cold rolled steel, 600×600×600mm, with tray, fan and cable manager1SetKITOZEREquipment installation
6Optical Fiber ModuleKITOZER-OM-GEGigabit multimode optical module, 550m transmission distance, SC interface, compatible with gigabit network cards2PcsKITOZERInterconnection between front-end & back-end servers

5.2 Medium Security Level Configuration List (Enhanced Model, KITOZER-E Series)

表格

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1Primary Front-End ServerKITOZER-FE-E219-inch 2U rack-mounted; Quad-core 2.5GHz CPU; 8GB DDR4 RAM; 1TB SATA HDD (RAID1); 4×Gigabit Electrical + 2×Gigabit Optical Ports; Dual redundant 400W power supplies; Full protocol support; Virus scanning, IDS, data desensitization, load balancing, hot standby, link aggregation1SetKITOZERPrimary device for external network access
2Standby Front-End ServerKITOZER-FE-E2Identical parameters to primary front-end server1SetKITOZERStandby device for automatic fault switchover
3Primary Back-End ServerKITOZER-BE-E2Same hardware specs as FE-E2; RBAC refined permission control, log auditing, data verification, emergency switchover, national cryptographic algorithm support1SetKITOZERPrimary device for internal network interconnection
4Standby Back-End ServerKITOZER-BE-E2Identical parameters to primary back-end server1SetKITOZERStandby device for automatic fault switchover
5Isolation Switch Unit (Two-Way Network Gateway)KITOZER-ISU-E219-inch 2U rack-mounted; 2+1 architecture with FPGA isolation chip; 1Gbps transmission rate; Full protocol stripping, raw data block ferry, breakpoint resume, integrity verification1SetKITOZERIsolated ferry between front & back-end servers
6System Management SoftwareKITOZER-SM-EFull-featured configuration, real-time monitoring, hierarchical permission control, policy distribution, log export, alarm management; Web visualization; Supports up to 500 devices; Remote O&M & automatic firmware upgrade1SetKITOZERIncludes 3-year free upgrade service
7Security Protection SoftwareKITOZER-SP-EVirus scanning, IDS, data desensitization, access control, encryption/decryption; Supports national cryptography SM1/SM2/SM3/SM4; Class III Cybersecurity Classified Protection compliant policies & log traceability1SetKITOZEREnhanced security defense
8Log Auditing SoftwareKITOZER-LA-EFull-process log recording, report generation, traceability analysis, compliance auditing; 1TB storage capacity; Log export, anomaly alarm, Class III compliance report generation1SetKITOZERMeet regulatory compliance requirements
9Supporting CabinetKITOZER-C-22U22U standard cabinet, cold rolled steel, 600×800×1200mm, with tray, fan, cable manager & PDU power supply1SetKITOZEREquipment installation
10Optical Fiber ModuleKITOZER-OM-GE-SMGigabit single-mode optical module, 10km transmission distance, SC interface, compatible with gigabit optical ports4PcsKITOZERInterconnection between gateway & front/back-end servers
11Redundant Power ModuleKITOZER-PWR-E400W redundant power supply, 100-240V AC input, 12V DC output; Hot-swappable, automatic fault switchover4PcsKITOZERRedundant power supply for front & back-end servers

5.3 High Security Level Configuration List (Flagship Model, KITOZER-P Series)

表格

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1Primary Front-End ServerKITOZER-FE-P319-inch 4U rack-mounted; Octa-core 3.0GHz CPU; 16GB DDR4 RAM; 2TB SSD (RAID10); 8×Gigabit Electrical + 4×10G Optical Ports; Dual redundant 600W power supplies; Full-depth protocol parsing including industrial protocols; Hardware encryption, virus defense, DDoS protection, cluster deployment, one/two-way transmission compatible1SetKITOZERPrimary device for external / non-classified network access
2Standby Front-End ServerKITOZER-FE-P3Identical parameters to primary front-end server1SetKITOZERStandby device for automatic fault switchover
3Primary Back-End ServerKITOZER-BE-P3Same hardware specs as FE-P3; Hierarchical permission control, full log auditing, data disaster recovery, emergency switchover, classified network adaptation, classified information evaluation compliance1SetKITOZERPrimary device for classified / core internal network interconnection
4Standby Back-End ServerKITOZER-BE-P3Identical parameters to primary back-end server1SetKITOZERStandby device for automatic fault switchover
5Isolation Switch Unit (One-Way Optical Gateway)KITOZER-ISU-P319-inch 2U rack-mounted; Unidirectional optical channel FPGA architecture with no reverse link; 10Gbps transmission rate; Raw data block ferry, national cryptographic encrypted transmission, integrity verification1SetKITOZERClassified scenario one-way data ferry
6Isolation Switch Unit (Two-Way Network Gateway)KITOZER-ISU-P3-DSame hardware as one-way optical gateway, supports controllable two-way transmission; Two-way physical isolation, high-concurrency encrypted transmission1SetKITOZERNon-classified core scenario two-way data exchange
7System Management SoftwareKITOZER-SM-PFull-featured cluster management, real-time monitoring, hierarchical permission control, intelligent policy distribution, full log storage, linked alarm disposal; Web + CLI dual interfaces; Supports up to 1000-device clusters; Remote O&M, automatic upgrade, disaster recovery management1SetKITOZER5-year free upgrade + lifetime technical support
8Security Protection SoftwareKITOZER-SP-PHardware national cryptographic encryption, virus scanning, intrusion prevention, data desensitization, DDoS & industrial control attack defense; Class IV Cybersecurity & classified evaluation compliant full-link filtering policies1SetKITOZERFlagship-grade security defense
9Log Auditing SoftwareKITOZER-LA-PFull-process log recording, storage, analysis, traceability & compliance audit; 4TB encrypted log storage; Anomaly alarm, operation playback, Class IV / classified evaluation compliance report generation1SetKITOZERMeet high-level regulatory compliance standards
10Emergency Disaster Recovery SoftwareKITOZER-DR-PScheduled / real-time / off-site data backup; Automatic fault switchover, minute-level recovery, zero business interruption; Disaster recovery simulation, data verification, emergency disposal1SetKITOZERCore business continuity guarantee
11Supporting CabinetKITOZER-C-42U42U standard cabinet, premium cold rolled steel, 600×1000×2000mm, with tray, fan, cable manager, PDU & temperature control module1SetKITOZEREquipment installation
1210G Optical Fiber ModuleKITOZER-OM-10G-SM10G single-mode optical module, 40km transmission distance, LC interface, compatible with 10G optical ports8PcsKITOZERInterconnection between gateways & front/back-end servers
13Redundant Power ModuleKITOZER-PWR-P600W redundant power supply, 100-240V AC input, 12V DC output; Hot-swappable, automatic fault switchover, redundant power supply4PcsKITOZERPower supply for front & back-end servers
14Encryption CardKITOZER-ENC-PNational cryptographic hardware encryption card supporting SM1/SM2/SM3/SM4; PCIe interface, data transmission/storage encryption & key management2PcsKITOZERHardware encryption for front & back-end servers

6. Full Product Technical Specifications

6.1 Front-End Server Series (KITOZER-FE)

6.1.1 KITOZER-FE-B1 (Low Security Level)

  • Hardware Specs: 19-inch 1U rack-mounted, Dual-core 2.0GHz CPU, 4GB DDR4 RAM, 500GB SATA HDD, 2×Gigabit Electrical Ports, Single 300W Power Supply
  • Protocol Support: Basic HTTP, FTP parsing & forwarding
  • Security Functions: Basic IP/port access control, operation log recording, traffic monitoring
  • Performance Metrics: Max concurrent connections: 1,000; Max throughput: 100Mbps; Log storage capacity: 500GB
  • Environmental Parameters: Operating temperature 0–40℃, Humidity 10%–90% (non-condensing), Input voltage 100–240V AC

6.1.2 KITOZER-FE-E2 (Medium Security Level)

  • Hardware Specs: 19-inch 2U rack-mounted, Quad-core 2.5GHz CPU, 8GB DDR4 RAM, 1TB SATA HDD (RAID1), 4×Gigabit Electrical + 2×Gigabit Optical Ports, Dual 400W Hot-Swappable Redundant Power Supplies
  • Protocol Support: Full parsing of HTTP/HTTPS, FTP/SFTP, SMTP, Telnet, SSH
  • Security Functions: Daily-updated virus scanning, intrusion detection, sensitive data desensitization (ID/phone/bank card masking), load balancing, link aggregation, dual-server hot standby, national cryptography SM1/SM2/SM3/SM4 support
  • Performance Metrics: Max concurrent connections: 5,000; Max throughput: 1Gbps; Log storage capacity: 1TB
  • Environmental Parameters: Operating temperature -10–50℃, Humidity 10%–95% (non-condensing), Input voltage 100–240V AC, Hot-swap support

6.1.3 KITOZER-FE-P3 (High Security Level)

  • Hardware Specs: 19-inch 4U rack-mounted, Octa-core 3.0GHz CPU, 16GB DDR4 RAM, 2TB SSD (RAID10), 8×Gigabit Electrical + 4×10G Optical Ports, Dual 600W Redundant Power Supplies, Hardware encryption card expansion slot
  • Protocol Support: Full-depth parsing of general & industrial protocols (HTTP/HTTPS, FTP/SFTP, SMTP, SSH, Modbus, OPC UA, database protocols)
  • Security Functions: Hardware national cryptographic full-link encryption, virus scanning, intrusion prevention, data desensitization, load balancing, DDoS & industrial control attack defense, cluster deployment, one/two-way transmission adaptation
  • Performance Metrics: Max concurrent connections: 20,000; Max throughput: 10Gbps; Log storage capacity: 4TB, fully compliant with classified information evaluation standards
  • Environmental Parameters: Operating temperature -20–60℃, Humidity 5%–95% (non-condensing), Input voltage 100–240V AC, Hot-swap & remote hardware management support

6.2 Back-End Server Series (KITOZER-BE)

6.2.1 KITOZER-BE-B1 (Low Security Level)

  • Hardware, protocol, performance & environmental parameters identical to KITOZER-FE-B1
  • Security Functions: Basic user/role permission control, log storage, data forwarding filtering

6.2.2 KITOZER-BE-E2 (Medium Security Level)

  • Hardware, protocol, performance & environmental parameters identical to KITOZER-FE-E2
  • Security Functions: RBAC refined hierarchical permission control, full log auditing, data integrity verification, emergency automatic switchover, national cryptographic encryption support, Class III Cybersecurity compliance audit

6.2.3 KITOZER-BE-P3 (High Security Level)

  • Hardware, protocol, performance & environmental parameters identical to KITOZER-FE-P3
  • Security Functions: Multi-level permission management, full-process log auditing, data disaster recovery, emergency switchover, classified network deployment adaptation, classified information evaluation compliance, hardware encryption support, cluster deployment for zero-downtime core business

6.3 Isolation Switch Unit Series (KITOZER-ISU)

6.3.1 KITOZER-ISU-E2 (Medium Security Level Two-Way Network Gateway)

  • Hardware Architecture: 2+1 structure with FPGA isolation chip
  • Transmission Rate: 1Gbps
  • Isolation Capability: Full-link protocol stripping, no network-layer connection, reverse attack blocking
  • Transmission Mode: Controllable two-way data ferry, breakpoint resume, data integrity verification
  • Interfaces: 2×Gigabit Electrical + 2×Gigabit Optical Ports
  • Power Supply: Dual 400W Hot-Swappable Redundant Power Supplies
  • Environmental Parameters: Operating temperature -10–50℃, Humidity 10%–95% (non-condensing)

6.3.2 KITOZER-ISU-P3 (High Security Level One-Way Optical Gateway)

  • Hardware Architecture: Unidirectional optical channel FPGA chip, zero reverse data link for physical one-way isolation
  • Transmission Rate: 10Gbps
  • Isolation Capability: Absolute physical one-way isolation, data flows one-way only to eliminate reverse information leakage risks
  • Transmission Mode: Raw data block ferry with national cryptographic encrypted transmission & integrity verification
  • Interfaces: 2×Gigabit Electrical + 2×10G Optical Ports
  • Power Supply: Dual 600W Hot-Swappable Redundant Power Supplies
  • Environmental Parameters: Operating temperature -20–60℃, Humidity 5%–95% (non-condensing)

6.3.3 KITOZER-ISU-P3-D (High Security Level Two-Way Network Gateway)

  • Hardware Architecture: 2+1 FPGA isolation chip structure, bidirectional physical isolation to block two-way reverse attacks
  • Transmission Rate: 10Gbps
  • Isolation Capability: Full-link protocol stripping, controllable bidirectional encrypted ferry for high-concurrency cross-network data exchange
  • Interfaces: 2×Gigabit Electrical + 2×10G Optical Ports
  • Power Supply: Dual 600W Hot-Swappable Redundant Power Supplies
  • Environmental Parameters: Consistent with KITOZER-ISU-P3

6.4 Software Series (KITOZER-SM / SP / LA / DR)

6.4.1 KITOZER-SM System Management Software

  • Interfaces: Visual Web UI + CLI command line
  • Management Capacity: B series supports up to 100 devices; E series up to 500 devices; P series up to 1,000-device clusters
  • Core Functions: Device configuration, real-time status monitoring, hierarchical permission control, policy batch distribution, alarm linkage disposal, remote O&M, automatic firmware upgrade
  • Compatibility: Windows, Linux, Unix OS, compatible with mainstream browsers

6.4.2 KITOZER-SP Security Protection Software

  • Defense Engines: Virus scanning, intrusion detection/prevention, data desensitization, encryption & decryption engines
  • Cryptography Support: E series supports SM1/SM2/SM3/SM4 national cryptography; P series supports full national cryptography + international encryption algorithms
  • Policy Library: Customizable security policies, pre-built Class III / IV Cybersecurity & classified evaluation compliance policy templates
  • Update Frequency: B series quarterly signature updates; E series daily updates; P series real-time threat signature updates

6.4.3 KITOZER-LA Log Auditing Software

  • Log Coverage: Data transmission logs, device operation logs, security alarm logs, permission change logs (zero omission)
  • Storage Capacity: E series 1TB storage; P series 4TB encrypted storage
  • Core Functions: Log query, export, compliance report generation, full traceability, anomaly alert, operation playback
  • Compliance Output: Automatic generation of Class III / IV Cybersecurity and classified evaluation audit reports

6.4.4 KITOZER-DR Emergency Disaster Recovery Software (P Series Exclusive)

  • Backup Modes: Scheduled backup, real-time backup, off-site remote backup
  • Recovery Capability: Automatic primary/standby switchover, minute-level full data recovery, zero business interruption
  • Core Functions: Disaster recovery simulation drills, data integrity verification, emergency incident disposal, centralized backup management
  • Compatibility: Compatible with mainstream databases, file systems and enterprise business systems

6.5 Supporting Products

6.5.1 Optical Fiber Modules

  • Gigabit Multimode (KITOZER-OM-GE): 550m transmission, SC interface
  • Gigabit Single-Mode (KITOZER-OM-GE-SM): 10km transmission, SC interface
  • 10G Single-Mode (KITOZER-OM-10G-SM): 40km transmission, LC interface

6.5.2 Redundant Power Modules

  • E Series (KITOZER-PWR-E): 400W, 100–240V AC input, 12V DC output, hot-swappable, automatic fault switchover
  • P Series (KITOZER-PWR-P): 600W, 100–240V AC input, 12V DC output, hot-swappable, high conversion efficiency ≥90%

6.5.3 Encryption Card (KITOZER-ENC-P)

  • Cryptography Algorithms: SM1/SM2/SM3/SM4 national cryptography suite
  • Interface: PCIe expansion slot
  • Functions: Hardware-accelerated transmission & storage encryption, centralized key management, offload CPU encryption workloads, encryption throughput ≥1Gbps

7. Full Product Application Scope

7.1 Front-End & Back-End Servers (All Series)

  • E-Government: Secure data exchange between internal & external government networks, government platform interconnection, sensitive government data transmission, Class III Cybersecurity Classified Protection construction
  • Finance: Cross-branch data interconnection for banks, securities and insurance firms, UnionPay message transmission, encrypted transaction data, anti-fraud protection, financial data disaster recovery
  • Energy: Isolation between office networks and industrial control networks (power, petroleum, chemical), secure industrial data transmission, industrial control attack defense, safe exchange of production data
  • Public Security / Court / Procuratorate: One-way data ferry between classified & non-classified networks, secure transmission of case data, classified information protection, classified information evaluation compliance construction
  • Healthcare: Isolation between hospital HIS/LIS systems and external networks, patient privacy data desensitization, secure medical data transmission, cybersecurity compliance
  • Education: Isolation between campus networks and core business networks, secure transmission of academic data, research data protection, student information desensitization
  • Small & Medium Enterprises: Office network security control, external access restriction, basic data isolation, low-cost enterprise security construction

7.2 Isolation Switch Units (Network / Optical Gateways)

  • One-Way Optical Gateway (P Series): Data collection from external networks to classified networks, absolute elimination of reverse leakage, high-level classified information scenarios
  • Two-Way Network Gateway (E/P Series): Controllable bidirectional data exchange between non-classified networks, cross-network business interconnection, medium & high security level scenarios

7.3 Software Series

  • System Management Software: Centralized unified management of all devices, large-scale cluster control, remote operation & maintenance, batch configuration distribution
  • Security Protection Software: End-to-end device security hardening, malicious traffic interception, sensitive data filtering, full-link encryption protection
  • Log Auditing Software: Compliance audit, security incident traceability, Class III / IV Cybersecurity & classified evaluation report generation
  • Emergency Disaster Recovery Software: Core business data backup & recovery, fault emergency response, business continuity guarantee

7.4 Supporting Products

  • Optical Fiber Modules: Interconnection between front/back-end servers and isolation gateways, long-distance high-speed data transmission
  • Redundant Power Supplies: High-availability power supply for key devices, automatic switchover to avoid single-point power failure
  • Encryption Cards: Hardware-accelerated national cryptographic encryption for high-security classified scenarios, full-link data confidentiality protection

8. Full Product Advantages

8.1 Core Functional Advantages

  1. Hardware-Level Isolation Protection Adopts the “2+1” hardware architecture with network/optical gateways delivering physical isolation, completely cutting off network-layer connections to fundamentally defend against reverse attacks, unauthorized access and ransomware infections, far more secure than purely software-based security devices.
  2. Full-Protocol Intelligent Adaptation Supports mainstream general protocols (HTTP/HTTPS, FTP, SMTP) and industrial protocols (Modbus, OPC UA) to resolve heterogeneous system compatibility issues, enabling fast deployment without modifying existing business systems.
  3. Full-Link National Cryptography Encryption Medium & high-end models support SM1/SM2/SM3/SM4 national cryptographic algorithms for end-to-end encryption of data transmission, processing and storage, fully meeting Class III / IV Cybersecurity and classified evaluation compliance standards to guarantee data confidentiality and integrity.
  4. Pre-Data Security Processing Integrates built-in data desensitization, virus scanning, intrusion detection and load balancing. The front-end server filters and cleans external data to forward only trusted data streams, reducing load on internal core servers and improving business response efficiency.
  5. High Availability & Stable Operation Supports dual-server hot standby, distributed cluster deployment and redundant hot-swappable power supplies with automatic fault switchover to eliminate single points of failure, ensuring 7×24-hour uninterrupted operation for finance, government and energy industries with strict availability requirements.
  6. Visualized Easy Management Intuitive Web visual management interface integrates device configuration, real-time status monitoring, security policy distribution, log query and alarm management in one platform, lowering operation & maintenance technical thresholds and costs.

8.2 Customization & Service Advantages

  1. In-Depth Custom Development Customizable hardware specifications, software functions, protocol parsing rules and security policies tailored to unique industry scenario demands, with dedicated one-on-one solution design teams.
  2. Full-Series OEM / ODM Support Supports private label customization including device appearance, logo branding and software UI, enabling partners to build independent proprietary brands with flexible market adaptation.
  3. Strict Confidentiality Mechanism Non-disclosure agreements signed with all clients; all customized solutions, technical parameters and project documents strictly confidential to eliminate information leakage risks and protect project security.
  4. Adequate Spot Inventory Full product range stocked in large quantities for standard configurations, enabling fast delivery of standard orders and short lead times for urgent customer deployments.
  5. Full Open Technical Documentation Complete, detailed technical specification manuals provided for product testing, solution design and regulatory compliance assessment, accelerating project delivery and acceptance.

8.3 Industry Differentiated Advantages

  • Government Industry: Compliant with national e-government cross-network exchange standards, dedicated government protocol adaptation, fully meets Class III Cybersecurity Classified Protection standards to support digital government transformation.
  • Financial Industry: Native UnionPay message parsing, transaction data encryption, anti-fraud traffic filtering, optimized for high-concurrency ultra-high security financial transaction scenarios to guarantee stable, secure capital settlement.
  • Industrial Industry: Deep parsing of Modbus/OPC UA industrial protocols, dedicated industrial control attack defense, physical isolation between production control networks and office networks to avoid production shutdown incidents caused by network threats.
  • Classified Industry: Physical one-way isolation via optical gateways, full national cryptographic encryption, fully compliant with classified information evaluation standards to eliminate all risks of classified data leakage.

9. Product Bidding Specification Parameters (Marked with *)

9.1 Front-End Server Bidding Parameters

9.1.1 KITOZER-FE-B1 (Low Security Level)

  • *19-inch 1U standard rack-mounted design compatible with standard server cabinets
  • *Supports basic HTTP and FTP protocol parsing & forwarding for fundamental cross-network data transmission
  • *Built-in basic access control (IP/port filtering) to block simple network intrusions
  • *Persistent operation log storage with minimum 500GB capacity to support basic security incident traceability

9.1.2 KITOZER-FE-E2 (Medium Security Level)

  • *19-inch 2U rack-mounted chassis, Quad-core ≥2.5GHz CPU, ≥8GB DDR4 RAM, ≥1TB SATA HDD with hardware RAID1 redundancy to guarantee stable high-performance operation
  • *Equipped with ≥4×Gigabit Electrical Ports + ≥2×Gigabit Optical Ports, supporting link aggregation for multi-port high-speed transmission
  • *Dual hot-swappable redundant power supplies with automatic fault switchover to eliminate single-point power failure risks
  • *Full parsing of HTTP/HTTPS, FTP/SFTP, SMTP, Telnet and SSH protocols to adapt to complex heterogeneous network environments
  • *Integrated virus scanning, intrusion detection and sensitive data desensitization modules, supporting SM1/SM2/SM3/SM4 national cryptographic algorithm encryption
  • *Dual-server hot standby architecture, maximum concurrent connections ≥5,000, peak throughput ≥1Gbps to support stable high-concurrency business operation

9.1.3 KITOZER-FE-P3 (High Security Level)

  • *19-inch 4U rack-mounted flagship chassis, Octa-core ≥3.0GHz CPU, ≥16GB DDR4 RAM, ≥2TB SSD with RAID10 array for top-tier hardware performance
  • *Equipped with ≥8×Gigabit Electrical Ports + ≥4×10G Optical Ports to support 10G high-bandwidth transmission for large-scale data centers
  • *Dual redundant power supplies + expandable hardware encryption card slot, full national cryptographic end-to-end encryption compliant with classified evaluation standards
  • *Full-depth parsing of general and industrial protocols including Modbus and OPC UA for industrial control and classified high-security scenarios
  • *Built-in DDoS mitigation and industrial control attack defense modules, supporting distributed cluster deployment, maximum concurrent connections ≥20,000, peak throughput ≥10Gbps
  • *Compatible with both one-way and two-way transmission architectures to meet strict isolation requirements of classified core business networks

9.2 Back-End Server Bidding Parameters

9.2.1 KITOZER-BE-B1 (Low Security Level)

  • *Hardware specifications and core basic functional bidding parameters identical to KITOZER-FE-B1
  • *Built-in basic user/role permission management to secure internal network data access
  • *Persistent log storage and data forwarding filtering capabilities to meet fundamental internal data processing security demands

9.2.2 KITOZER-BE-E2 (Medium Security Level)

  • *Hardware specifications and core functional bidding parameters identical to KITOZER-FE-E2
  • *Adopts RBAC multi-level refined permission control to implement least-privilege access management
  • *Integrated full log auditing, data integrity verification and emergency automatic switchover modules, fully compliant with Class III Cybersecurity audit requirements
  • *Supports national cryptographic encryption for internal data storage and transmission security

9.2.3 KITOZER-BE-P3 (High Security Level)

  • *Hardware specifications and core functional bidding parameters identical to KITOZER-FE-P3
  • *Multi-level hierarchical permission control, full-process log auditing, integrated data disaster recovery and emergency switchover, fully compliant with classified information evaluation standards
  • *Optimized for classified network deployment to securely process and transmit classified data and eliminate leakage risks
  • *Distributed cluster deployment support to guarantee uninterrupted high-availability core business operation

9.3 Isolation Switch Unit Bidding Parameters

9.3.1 KITOZER-ISU-E2 (Medium Security Level Two-Way Network Gateway)

  • *Adopts 2+1 hardware architecture with FPGA isolation chip, full-link protocol stripping with zero network-layer connection between internal and external networks
  • *Minimum transmission throughput ≥1Gbps, supports controllable two-way data ferry, breakpoint resume and data integrity verification
  • *Equipped with ≥2×Gigabit Electrical Ports + ≥2×Gigabit Optical Ports for gigabit interconnection with front & back-end servers
  • *Dual hot-swappable redundant power supplies to guarantee high-availability device operation

9.3.2 KITOZER-ISU-P3 (High Security Level One-Way Optical Gateway)

  • *Unidirectional optical channel hardware architecture with zero reverse data link to realize absolute physical one-way isolation (data can only flow from external to classified networks)
  • *Minimum transmission throughput ≥10Gbps, supports national cryptographic encrypted transmission and data integrity verification to completely eliminate reverse classified information leakage risks
  • *Equipped with ≥2×Gigabit Electrical Ports + ≥2×10G Optical Ports for 10G high-speed interconnection with front & back-end servers
  • *Dual hot-swappable redundant power supplies to support 7×24-hour uninterrupted operation of classified core systems

9.3.3 KITOZER-ISU-P3-D (High Security Level Two-Way Network Gateway)

  • *2+1 hardware architecture with FPGA isolation chip delivering bidirectional physical isolation to block reverse attacks in both directions
  • *Minimum transmission throughput ≥10Gbps, supports controllable two-way encrypted ferry for high-concurrency cross-network data exchange scenarios
  • *Equipped with ≥2×Gigabit Electrical Ports + ≥2×10G Optical Ports for high-bandwidth large-scale business interconnection
  • *Dual hot-swappable redundant power supplies to guarantee stable operation of core high-availability business systems

9.4 Software Series Bidding Parameters

9.4.1 KITOZER-SM System Management Software

  • *Dual management interfaces: Visual Web UI + CLI command line, compatible with diverse operation & maintenance workflows
  • *E series supports centralized management of ≥500 devices; P series supports cluster management of ≥1,000 devices for large-scale equipment fleets
  • *Built-in remote O&M, automatic firmware upgrade and linked alarm disposal functions to reduce operation & maintenance labor costs and improve management efficiency

9.4.2 KITOZER-SP Security Protection Software

  • *Integrates four core defense engines: virus scanning, intrusion detection/prevention, data desensitization and encryption/decryption
  • *E series supports SM1/SM2/SM3/SM4 national cryptography suite; P series supports full national cryptography plus international encryption algorithms
  • *Pre-built customizable security policy templates for Class III / IV Cybersecurity and classified information evaluation compliance to meet multi-level regulatory requirements

9.4.3 KITOZER-LA Log Auditing Software

  • *Records four categories of logs without omission: cross-network data transmission logs, device operation logs, security alarm logs and permission modification logs
  • *P series minimum encrypted log storage capacity ≥4TB, supporting anomaly alert and full operation playback
  • *Automatically generates standard compliance audit reports for Class III / IV Cybersecurity and classified information evaluation to satisfy regulatory traceability demands

9.4.4 KITOZER-DR Emergency Disaster Recovery Software

  • *Supports three backup modes: scheduled automatic backup, real-time synchronous backup and off-site remote backup for multi-layer data protection
  • *Automatic primary/standby fault switchover, minute-level full data recovery with zero business interruption to meet core business disaster recovery standards
  • *Built-in disaster recovery simulation, data integrity verification and emergency incident disposal modules to improve emergency response reliability

9.5 Supporting Product Bidding Parameters

9.5.1 Optical Fiber Modules

  • Gigabit multimode transmission distance ≥550m; Gigabit single-mode ≥10km; 10G single-mode ≥40km
  • Compatible with mainstream switches, servers and security device optical ports with stable transmission performance

9.5.2 Redundant Power Modules

  • E series rated power ≥400W; P series rated power ≥600W, universal 100–240V AC global input voltage
  • Hot-swappable design with automatic fault switchover, power conversion efficiency ≥90% for energy-saving stable power supply

9.5.3 Encryption Card

  • Fully supports SM1/SM2/SM3/SM4 national cryptography algorithms, PCIe expansion interface compatible with front & back-end servers
  • Hardware-accelerated encryption throughput ≥1Gbps, no CPU resource occupation to balance encryption efficiency and device performance

10. Full Product Industry Solutions

10.1 E-Government Internal & External Network Data Exchange Solution

10.1.1 Pain Points

Government internal and external networks require physical isolation while enabling secure exchange of government documents, livelihood data and approval information; sensitive government data must be desensitized; full compliance with Class III Cybersecurity Classified Protection standards is mandatory; transmission efficiency, stability and full auditability must be guaranteed.

10.1.2 Solution Design

Deployment Architecture: External Government Network → Firewall → KITOZER-FE-E2 Front-End Server → KITOZER-ISU-E2 Two-Way Network Gateway → KITOZER-BE-E2 Back-End Server → Internal Government Network Core Switch → Government Business Systems Core Configuration: Medium-grade E series deployment, dual-server hot standby for front & back-end servers, two-way isolation gateway, integrated data desensitization, full log auditing and national cryptographic encryption functions Security Policy: Government-dedicated security rule templates, automatic masking of sensitive fields (ID numbers, phone numbers, confidential document tags), priority parsing of government dedicated protocols, log retention period ≥6 months for full traceability

10.1.3 Solution Value

  1. Realizes controllable secure cross-network data exchange between government internal and external networks, physical isolation blocks external network attack penetration
  2. Automatic sensitive data desensitization eliminates citizen privacy leakage risks
  3. Fully meets Class III Cybersecurity Classified Protection compliance standards with complete audit and traceability logs
  4. Dual-server hot standby guarantees 7×24-hour uninterrupted government service operation, boosting overall government service efficiency by 40%

10.2 Financial Cross-Network Transaction Data Transmission Solution

10.2.1 Pain Points

Bank headquarters and nationwide branches require cross-network transmission of transaction data, customer information and clearing data with ultra-high security, concurrency and stability; transaction data must be encrypted and tamper-proof; accurate parsing of UnionPay messages is required; defense against fraud and ransomware attacks is mandatory to meet strict financial regulatory compliance standards.

10.2.2 Solution Design

Deployment Architecture: Branch External Network → Firewall → KITOZER-FE-P3 Front-End Server → KITOZER-ISU-P3-D Two-Way 10G Network Gateway → KITOZER-BE-P3 Back-End Server → Headquarters Core Switch → Core Transaction System Core Configuration: High-grade P series flagship deployment, distributed cluster front-end servers, dual hot standby back-end servers, dual redundant 10G two-way isolation gateways, integrated full national cryptographic end-to-end encryption, DDoS mitigation, UnionPay message parsing and full transaction log traceability Security Policy: Financial industry dedicated defense rules, real-time transaction data encryption & integrity verification, automatic interception of abnormal fraudulent transactions, full-process transaction log retention ≥1 year for regulatory audit

10.2.3 Solution Value

  1. Distributed cluster architecture supports 5,000+ concurrent transactions per second, 10G high-speed transmission guarantees real-time capital settlement
  2. National cryptographic encryption + data integrity verification ensures transaction data confidentiality, integrity and non-repudiation
  3. Native UnionPay message parsing achieves 100% heterogeneous banking system interconnection success rate
  4. Built-in anti-fraud and ransomware defense blocks over 1,000 targeted financial cyberattacks annually
  5. Fully compliant with financial industry regulatory standards with complete traceable audit logs, zero annual security incidents and 99.999% business stability

10.3 Classified Network One-Way Data Ferry Solution

10.3.1 Pain Points

Classified networks prohibit direct access from external networks and require one-way collection of research documents, experimental data and literature from non-classified collaboration networks; absolute elimination of reverse classified information leakage risks; national cryptographic encryption for all classified data; full compliance with classified information evaluation standards; complete data transmission accuracy and integrity guarantees.

10.3.2 Solution Design

Deployment Architecture: Non-Classified External Network → Firewall → KITOZER-FE-P3 Front-End Server → KITOZER-ISU-P3 One-Way Optical Gateway → KITOZER-BE-P3 Back-End Server → Classified Network Core Switch → Confidential Research Systems Core Configuration: High-grade P series flagship deployment, dual hot standby front & back-end servers, physical one-way optical isolation gateway, integrated national cryptographic encryption, full data integrity verification and classified encrypted log auditing Security Policy: Classified dedicated security rules, absolute one-way data transmission with zero reverse data flow, national cryptographic encryption for all classified data, encrypted log storage with dedicated administrator access control

10.3.3 Solution Value

  1. Physical unidirectional optical isolation completely eliminates reverse classified information leakage risks, fully passing Level 1 classified information evaluation
  2. Full-link national cryptographic encryption protects confidentiality of classified research data during transmission and storage
  3. Mandatory data integrity verification achieves 100% accuracy of ferried research data
  4. Fully compliant with classified information evaluation standards with encrypted traceable audit logs
  5. Dual-server hot standby guarantees uninterrupted daily data collection of over 5TB to support confidential research progress

10.4 Industrial Control & Office Network Security Isolation Solution

10.4.1 Pain Points

Physical isolation between office networks and industrial control networks (power dispatching, power generation, equipment monitoring) is required to prevent office network viruses and cyberattacks from penetrating production control systems; deep parsing of Modbus/OPC UA industrial protocols is mandatory; secure transmission of production data must be guaranteed without disrupting real-time industrial control and causing production shutdown incidents.

10.4.2 Solution Design

Deployment Architecture: Office Network → Firewall → KITOZER-FE-E2 Front-End Server → KITOZER-ISU-E2 Two-Way Network Gateway → KITOZER-BE-E2 Back-End Server → Industrial Control Core Switch → PLC / SCADA Production Control Systems Core Configuration: Medium-grade E series deployment, optional single or dual hot standby front & back-end servers, two-way isolation gateway, integrated industrial protocol parsing and industrial control attack filtering modules Security Policy: Industrial dedicated defense templates, deep parsing of Modbus/OPC UA protocols, automatic interception of illegal industrial control instructions, full virus scanning for office network traffic, priority forwarding of real-time production data

10.4.3 Solution Value

  1. Physical isolation between office and industrial control networks blocks external attack penetration, zero industrial control security incidents annually
  2. Native industrial protocol parsing enables seamless heterogeneous industrial system interconnection without modification of existing production equipment
  3. Dedicated industrial control attack defense filters abnormal production instructions and malicious traffic to guarantee stable power dispatching and generation control
  4. Low-latency hardware architecture does not impact real-time industrial control signal transmission, ensuring stable safe power production

10.5 Small & Medium Enterprise Network Security Protection Solution

10.5.1 Pain Points

Small and medium enterprises have limited security budgets and demand low-cost basic network protection; external network access control to block unauthorized intrusions; fundamental core business data isolation; simple deployment and low operation & maintenance technical thresholds.

10.5.2 Solution Design

Deployment Architecture: External Network → Firewall → KITOZER-FE-B1 Front-End Server → KITOZER-BE-B1 Back-End Server → Internal Core Switch → Office / E-Commerce Business Systems Core Configuration: Low-grade B series basic single-machine deployment, no dedicated isolation gateway for simple isolation requirements, integrated basic IP/port access control, log recording and traffic filtering functions Security Policy: Basic entry-level security rules, IP/blacklist filtering to block malicious external access, lightweight virus scanning, granular access permission control for core order and customer data

10.5.3 Solution Value

  1. Ultra-low total deployment cost within 50,000 RMB, fully matching SME budget constraints
  2. Effective external access control blocks over 200 malicious IPs and unauthorized intrusion attempts annually
  3. Basic data isolation prevents internal virus spread and core business data leakage incidents
  4. One-day complete deployment with zero professional security technicians required for daily operation & maintenance
  5. Meets basic office and e-commerce business network security baseline requirements for SMEs

11. Full Product Application Cases

11.1 Provincial E-Government Internal & External Network Data Exchange Project

  • Project Background: A provincial government needed to break data barriers between internal and external government networks for secure exchange of government documents, livelihood data and administrative approval information, while fully complying with Class III Cybersecurity Classified Protection standards to guarantee data security and transmission efficiency.
  • Deployed Products: 2×KITOZER-FE-E2 (Primary/Standby Front-End Servers), 2×KITOZER-BE-E2 (Primary/Standby Back-End Servers), 1×KITOZER-ISU-E2 Two-Way Network Gateway, complete suite of system management, security protection and log auditing software
  • Project Outcomes: Realized controllable secure cross-network data exchange processing over 100,000 data records daily; automatic desensitization of sensitive citizen livelihood data eliminated privacy leakage risks; successfully passed Class III Cybersecurity Classified Protection assessment with complete traceable audit logs; dual-server hot standby delivered 7×24-hour uninterrupted government service operation, improving overall administrative service efficiency by 40%.

11.2 State-Owned Bank Headquarters-Branch Cross-Network Transaction Transmission Project

  • Project Background: A national state-owned bank with 30+ regional branches required cross-network interconnection with headquarters core transaction systems for transmission of transaction data, customer information and clearing records, demanding ultra-high security, concurrency and stability, anti-fraud protection and full financial regulatory compliance.
  • Deployed Products: 30+ Clustered KITOZER-FE-P3 Front-End Servers, 2×Clustered KITOZER-BE-P3 Back-End Servers, 2×Hot-Standby KITOZER-ISU-P3-D Two-Way 10G Network Gateways, full suite of system management, security protection, log auditing and emergency disaster recovery software
  • Project Outcomes: Distributed cluster architecture supports 5,000+ concurrent transactions per second with 10G low-latency transmission for real-time capital settlement; full national cryptographic encryption achieves zero transaction data leakage or tampering incidents; native UnionPay message parsing delivers 100% system interconnection success rate; over 1,000 fraudulent and ransomware attack attempts intercepted annually; fully passed financial regulatory compliance assessment with zero annual security incidents and 99.999% transaction stability.

11.3 Classified Research Institute One-Way Data Ferry Project

  • Project Background: A confidential scientific research institute required one-way collection of research papers, experimental data and literature resources from non-classified internet and collaborative networks to classified core research systems, with absolute elimination of reverse classified leakage risks and full compliance with national classified information evaluation standards.
  • Deployed Products: 2×Hot-Standby KITOZER-FE-P3 Front-End Servers, 2×Hot-Standby KITOZER-BE-P3 Back-End Servers, 1×KITOZER-ISU-P3 One-Way Optical Gateway, full suite of system management, security protection and log auditing software
  • Project Outcomes: Physical unidirectional optical isolation completely eliminated reverse classified leakage risks, successfully passing Level 1 classified information evaluation; full national cryptographic encryption guaranteed transmission and storage security of confidential research data; mandatory data integrity verification achieved 100% accuracy of ferried data; daily collection of over 5TB research data with dual-server hot standby guaranteeing uninterrupted confidential research workflows.

11.4 Large Power Enterprise Industrial Control Network Isolation Project

  • Project Background: A major power generation enterprise required physical isolation between office networks and industrial control networks (power dispatching, generation monitoring, equipment control) to prevent office network viruses and cyberattacks from penetrating production control systems and triggering power generation shutdown accidents.
  • Deployed Products: 1×KITOZER-FE-E2 Front-End Server, 1×KITOZER-BE-E2 Back-End Server, 1×KITOZER-ISU-E2 Two-Way Network Gateway, system management and security protection software suite
  • Project Outcomes: Physical isolation cut off all attack penetration paths from office networks to industrial control systems with zero annual production safety incidents; native Modbus/OPC UA industrial protocol parsing enabled seamless interconnection of heterogeneous power production equipment without hardware modification; automatic interception of illegal industrial control instructions and abnormal traffic guaranteed stable power dispatching and generation control; low-latency hardware design had no negative impact on real-time production control signals, supporting continuous safe power generation.

11.5 SME Office Network Security Protection Project

  • Project Background: A small e-commerce enterprise with 50 employees required low-cost office network security control to block unauthorized external intrusions and virus spread, protecting order and customer private data with simple deployment and minimal operation & maintenance overhead.
  • Deployed Products: 1×KITOZER-FE-B1 Front-End Server, 1×KITOZER-BE-B1 Back-End Server, system management and basic security protection software suite
  • Project Outcomes: Total deployment budget controlled under 50,000 RMB; IP blacklist filtering blocked over 200 malicious external access attempts annually; lightweight virus scanning eliminated office network virus outbreak risks; granular access permission control prevented core order and customer data leakage; full deployment completed within one working day with no dedicated security engineers required for daily management, fully matching SME low-cost security demands.

12. Product Fault Troubleshooting & Maintenance Guidelines

12.1 Common Faults & Resolution

12.1.1 Front-End / Back-End Server Hardware Faults

  1. Fault Phenomenon: Device fails to power on, power indicator off
    • Troubleshooting Steps: Inspect power cable connection, power socket power supply status, redundant power module integrity
    • Resolution: Re-seat power cables, replace power sockets, swap faulty redundant power modules; contact manufacturer repair if issue persists
  2. Fault Phenomenon: Device running slow, excessive CPU / RAM utilization
    • Troubleshooting Steps: Check abnormal background processes, virus infection, concurrent connection count exceeding hardware capacity
    • Resolution: Terminate abnormal processes, update virus signature database for full scanning, optimize security policies to limit concurrent connections; upgrade hardware specifications if performance remains insufficient
  3. Fault Phenomenon: Hard disk failure, data loss or storage failure
    • Troubleshooting Steps: Inspect hard disk status indicators, RAID array health, hard disk bad sector detection
    • Resolution: Replace faulty hard disk, rebuild RAID array, restore data from backup copies; implement regular scheduled backups to prevent permanent data loss
  4. Fault Phenomenon: Electrical / Optical port offline, data transmission interruption
    • Troubleshooting Steps: Inspect cable / fiber connection tightness, optical module integrity, physical port damage
    • Resolution: Re-seat network cables and fiber jumpers, replace aged optical modules; contact manufacturer repair if physical port hardware damage is confirmed

12.1.2 Isolation Switch Unit (Network / Optical Gateway) Faults

  1. Fault Phenomenon: Data ferry failure, complete transmission interruption
    • Troubleshooting Steps: Verify physical interconnection between gateway and front/back-end servers, isolation chip status, transmission policy configuration errors
    • Resolution: Re-establish physical connections, reboot isolation gateway, correct misconfigured transmission policies; contact manufacturer technical support if ferry function remains disabled
  2. Fault Phenomenon: Severe data packet loss, incomplete transmitted files
    • Troubleshooting Steps: Inspect bandwidth bottlenecks, aging optical modules, disabled data integrity verification policies
    • Resolution: Upgrade network bandwidth, replace degraded optical modules, enable mandatory data integrity verification rules to reduce packet loss ratio

12.1.3 Software System Faults

  1. Fault Phenomenon: Management software Web interface inaccessible, login failure
    • Troubleshooting Steps: Verify device IP address reachability, network connectivity, background management service status, browser compatibility
    • Resolution: Reboot server equipment, troubleshoot network communication, restart management service, switch to compatible mainstream browsers; contact manufacturer technical support if login remains impossible
  2. Fault Phenomenon: Security policies ineffective, malicious traffic not intercepted
    • Troubleshooting Steps: Inspect policy configuration correctness, policy distribution execution status, expired virus/threat signature database
    • Resolution: Correct misconfigured security rules, re-distribute policy templates, update virus/threat signature database; contact manufacturer support if interception capability remains abnormal
  3. Fault Phenomenon: Log recording / query failure, audit function disabled
    • Troubleshooting Steps: Inspect hard disk storage capacity overflow, background log service running status, log storage configuration parameters
    • Resolution: Clean redundant disk storage space, restart log service processes, correct log retention and storage configuration; contact manufacturer technical support if audit function remains abnormal

12.2 Daily Maintenance & Inspection Standards

12.2.1 Hardware Maintenance

  1. Environmental Control: Maintain clean, dry and well-ventilated equipment computer rooms; operating temperature range: P series -20~60℃, E series -10~50℃, B series 0~40℃; humidity controlled at 5%–95% without condensation, avoid direct sunlight, dust accumulation and strong electromagnetic interference
  2. Regular Inspection Schedule
    • Daily: Check power, operation, hard disk and port indicator lights; record real-time CPU, RAM, disk utilization and transmission throughput metrics
    • Weekly: Inspect tightness of power cables, fiber jumpers and network cables; verify normal operation of cooling fans
    • Monthly: Clean dust from equipment surfaces and heat dissipation vents to prevent overheating failures
  3. Hardware Replacement Cycle: Replace vulnerable components (redundant power supplies, optical modules) every 2 years; conduct full hard disk bad sector inspection every 3 years, replace faulty disks immediately and implement regular critical data backups

12.2.2 Software Maintenance

  1. Version Upgrade Rules: Quarterly software upgrades for B series; monthly upgrades for E series; real-time hotfix updates for P series to patch vulnerabilities, optimize functional modules and update virus/threat signature databases
  2. Policy Optimization: Dynamically adjust security rules according to business changes and emerging cyber threats; clean invalid redundant policies periodically and optimize policy priority sequences to improve defense efficiency
  3. Log Management: Regular backup and archiving of audit logs; minimum retention periods: E series ≥6 months, P series ≥1 year with encrypted storage to prevent unauthorized log tampering or deletion
  4. Account Security Management: Mandatory periodic strong password updates (combination of uppercase/lowercase letters, numbers and special symbols); regular cleanup of redundant and resigned employee accounts, implement strict least-privilege access assignment

12.2.3 Emergency Maintenance Protocols

  1. Fault Response Mechanism: Immediately activate emergency handling workflow upon equipment failure; prioritize simple troubleshooting (power, cabling, configuration); switch to standby hot-standby equipment simultaneously to avoid business interruption if basic troubleshooting fails, then contact manufacturer technical support
  2. Data Recovery Workflow: In case of hard disk failure or data loss, restore data from backup copies immediately, verify full data integrity post-recovery and conduct root cause analysis to prevent secondary data loss incidents
  3. Disaster Recovery Drills: Conduct quarterly disaster recovery simulation drills for P series emergency disaster recovery software, simulate equipment failure and data loss scenarios to test recovery efficiency and optimize emergency response procedures

13. Factory Strength & After-Sales Service System

13.1 Factory Production Strength

KITOZER is a national high-tech enterprise integrating R&D, production, sales and service of network and data security equipment, with over 10 years of deep expertise in front-end & back-end servers, network gateways and optical isolation gateways. Our products are widely deployed across government, finance, energy, public security and education industries, serving more than 1,000 enterprise clients nationwide with leading domestic market share.

  1. Production Base: 20,000㎡ modern manufacturing plant with 10 automated production lines covering full-process SMT chip mounting, welding, assembly and testing, annual production capacity of 50,000 security devices. Dust-free, anti-static workshop environments compliant with ISO9001 Quality Management System and ISO14001 Environmental Management System standards to guarantee consistent product quality.
  2. R&D Team: Over 100 professional R&D engineers, 30% consisting of PhD holders and senior technical specialists dedicated to data isolation technology, national cryptography algorithms and cross-network protocol parsing R&D. The company holds over 50 invention patents, 30 utility model patents and 100+ software copyrights, with multiple core technologies filling domestic technical gaps and reaching internationally advanced levels.
  3. Full-Process Quality Control: Strict quality inspection implemented across all production links: 100% incoming component testing for raw materials sourced from premium global suppliers (Intel, Samsung, etc.); batch sampling inspection during assembly; 100% full-function, pressure, compatibility and aging testing of finished products before factory delivery to eliminate defective shipments.
  4. Stable Supply Chain: Long-term strategic cooperation with core component suppliers to avoid raw material shortage risks; large stock inventory of standard hardware and core components for fast delivery: standard orders shipped within 7 working days, customized projects delivered within 15–30 working days.

13.2 Full-Cycle After-Sales Service System

Adhering to the service philosophy of “Customer First, Service Oriented”, KITOZER delivers a 7×24-hour full-lifecycle service system covering pre-sales consultation, in-sales solution design, post-sales installation & commissioning, technical training, fault troubleshooting, maintenance and iterative upgrades, with dedicated one-on-one technical account managers for all clients to guarantee stable equipment operation and uninterrupted business.

  1. Pre-Sales Services: Free technical consultation, demand research, customized solution design and equipment testing; tailored low/medium/high security level solutions based on client industry scenarios, security requirements and budget limits; free sample testing support for accurate product selection.
  2. In-Sales Services: Free on-site installation, commissioning and technical training by professional engineers; full equipment deployment, security policy configuration and system debugging to ensure normal operation; hands-on operation training for client internal technical staff covering equipment operation, policy configuration, daily maintenance and fault troubleshooting, with standardized printed training manuals for independent internal operation & maintenance.
  3. Post-Sales Support
    • 7×24-Hour Technical Response: National unified service hotline, online customer service and dedicated technical support email available round the clock; 15-minute initial response, 30-minute preliminary troubleshooting plan provision, 1-hour remote technical support for fast fault resolution.
    • Tiered On-Site Service Network: 30 direct service branches and 100+ authorized service centers covering all provinces and municipalities nationwide; 4-hour on-site arrival for provincial capitals and municipalities directly under central government, 8 hours for prefecture-level cities, 24 hours for county-level and remote regions; engineers carry replacement spare parts for one-time on-site fault resolution.
    • Warranty & Repair Policy: All products come with 3-year free factory warranty (far exceeding the industry standard 1-year warranty); free repair and component replacement for non-artificial damage within warranty period; lifetime free technical support, firmware upgrade and fault diagnosis; optional extended warranty service up to 5 years.
    • Regular Return Visits & Preventive Inspection: Client file archiving with monthly/quarterly telephone follow-ups and scheduled on-site inspections to monitor equipment operation status, identify potential hidden faults, optimize system configuration and provide targeted operation & maintenance recommendations to proactively avoid failures.
    • Emergency Disaster Recovery Priority Support: Priority standby equipment dispatch for P series flagship model faults to achieve zero business interruption; dedicated technical team to assist clients in regular disaster recovery drills and optimize emergency response workflows.
  4. Customization Service: Hardware appearance, software UI, functional modules, protocol parsing rules and security policy customization supported; dedicated exclusive R&D team assigned to each customized project, delivery cycle of 15–30 working days for customized products.
  5. Confidentiality Guarantee: Standard non-disclosure agreements signed with all clients; all project documents, technical parameters and customized solution data strictly confidential to eliminate information leakage risks and protect client project security.

14. Conclusion

As core hardware devices for network and data security, KITOZER front-end & back-end servers deliver outstanding core strengths including hardware physical isolation, full-link national cryptographic encryption, universal cross-industry protocol adaptation, high-availability stable operation and visualized simplified management. We provide tiered low/medium/high security level customized solutions tailored for government, finance, energy, classified research, industrial and SME scenarios, fully meeting Class III / IV Cybersecurity Classified Protection and national classified information evaluation compliance standards.

With over 10 years of technical accumulation and industry experience, KITOZER’s robust manufacturing capacity, rigorous quality control and comprehensive full-lifecycle after-sales service have enabled our products to run stably in more than 1,000 client projects nationwide, earning widespread industry recognition and customer trust. Moving forward, KITOZER will continue to focus on innovation in data security core technologies, continuously optimize product performance, expand functional modules and upgrade service quality, supporting enterprises across all industries to build more secure, stable and efficient multi-layered network defense systems and safeguard the safe development of the digital economy.

15. SEO Optimization Section

15.1 Search Keywords

Core Primary Keywords

Front-End & Back-End Server, Data Security Device, Network Secure Transmission Equipment, KITOZER Front-End & Back-End Server, Secure Data Exchange Device

High-Conversion Long-Tail Keywords

Government Front-End & Back-End Server, Financial Secure Data Front-End & Back-End Server, Classified Network One-Way Data Ferry Equipment, Industrial Control Network Isolation Equipment, SME Network Security Protection Device, Class III Cybersecurity Data Security Equipment, Classified Evaluation Compliance Security Device, KITOZER Data Security Solution

Industry Traffic Keywords

Network Security, Data Security, Security Isolation, Data Ferry, Protocol Conversion, Load Balancing, Log Auditing, National Cryptography Encryption, Cybersecurity Classified Protection Assessment, Classified Information Evaluation, Network Gateway, Optical Isolation Gateway, Front-End Server, Back-End Server, Industrial Cybersecurity, Government Cybersecurity, Financial Cybersecurity, Classified Information Security

Brand Exclusive Keywords

KITOZER, KITOZER Front-End Server, KITOZER Back-End Server, KITOZER Network Gateway, KITOZER Optical Gateway, KITOZER Data Security Device, KITOZER Security Solution

Drop-Down & Related Search Keywords

Front-End & Back-End Server Working Principle, Front-End & Back-End Server Configuration, Front-End & Back-End Server Application Scenarios, Front-End & Back-End Server Manufacturer, Front-End & Back-End Server Price, Data Security Isolation Device, Difference Between Network Gateway and Front-End Server, One-Way Optical Gateway Application, KITOZER Factory Strength, KITOZER After-Sales Service

15.2 SEO Optimization Tag System

Core Page Optimization Tag

Front-End & Back-End Server | Data Security Device | KITOZER Secure Data Exchange Solution

Title Tag

KITOZER Front-End & Back-End Server Solution – Data Security Equipment – Network Secure Transmission Protection

Meta Keywords Tag

Front-End & Back-End Server, Data Security Device, Network Secure Transmission, Secure Data Exchange, KITOZER, Network Gateway, Optical Isolation Gateway,

翻译得更通顺一些

把文章中“核心定位”翻译成英文

推荐一些翻译文章的网站

Shopping Cart