KITOZER
KITOZER

KITOZER front rear adjustable rack base

KITOZER KTR-FL14 Adjustable Cabinet Plinth (Front-Rear, Heavy Duty)

Brand: KITOZER Series: KTR-FL14 Category: Data Center Engineering / Cabinet Infrastructure

cabinet plinthfront-rear adjustableload basemodular cold aisleadjustable plinthKTR-FL14

[Product image: KITOZER KTR-FL14 adjustable rack plinth with front-rear telescoping feet]

1. Overview

KITOZER KTR-FL14 is an adjustable steel plinth installed under 19-inch server racks to lift the cabinet, align rows, and absorb uneven-floor tolerance. In modular cold-aisle containment, a row of racks must butt together to form a sealed aisle; every cabinet’s front-to-back position must line up so roof panels and end doors seal tightly. But data-center floors — especially the concrete under raised flooring — are never perfectly flat. Racks set directly on the floor end up misaligned, with uneven gaps and leaking containment. KTR-FL14 uses front-rear telescoping feet so installers can fine-tune each cabinet’s position after it is in place, lining the whole row into a straight line.

The plinth is a frame of front/rear main beams, left/right stringers, and four adjustable feet. The main beams have slotted holes; rack uprights bolt to the slots with M12 bolts — loosen them and slide the cabinet ±25 mm front-to-back, then re-tighten. Height is typically 100 or 150 mm, leaving under-floor cable space and matching the containment floor. Four feet with rubber anti-vibration pads sit on the concrete or pedestal, spreading the load.

KTR-FL14 main beams are bent from 2.0 mm cold-rolled steel, welded and powder-coated; rated load ≥1000 kg per plinth, enough for a fully loaded server rack (~800 kg). The front-rear adjustment is especially useful for cold-aisle retrofit projects — when existing racks are misaligned, you do not need to move the cabinet; just loosen the slot bolts and slide it into line. Side cable openings let power and network cables pass under the plinth into the rack.

2. Key Features

±25 mm front-rear adjust

  • Slotted holes allow post-install fine-tuning.
  • Loosen M12 bolts, slide front-rear.
  • Whole row can be aligned.

Heavy-duty load

  • 2.0 mm cold-rolled main beams.
  • ≥1000 kg per plinth.
  • Handles full server racks.

Anti-vibration feet

  • Four rubber pads.
  • Spreads load, protects floor.
  • Compensates minor unevenness.

Cold-aisle ready

  • 100/150 mm height.
  • Side cable openings.
  • Aligns with roof panels and end doors.

3. Specifications

Item KTR-FL14
Type Framed adjustable rack plinth
Adjustment Front-rear ±25 mm
Method Slotted hole + M12 bolt
Height 100 / 150 mm
Load rating ≥1000 kg
Beam thickness 2.0 mm cold-rolled steel
Finish Powder coat
Rack fit 19-inch standard rack
Feet 4 rubber anti-vibration pads
Cable opening Side cutout
Color Black / gray (optional)

4. Reference Prices

KTR-FL14 adjustable plinth (100 mm, 800×1000 rack, single): Reference USD 39~63 / unit (ref. CNY 280~450 at ~7.2)

KTR-FL14 adjustable plinth (150 mm, 800×1200 rack, heavy duty): Reference USD 67~108 / unit (ref. CNY 480~780 at ~7.2)

Reference only; priced by size, height, load rating. Bulk (10+) on request. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Cold-aisle containment rack plinths.
  • New data hall rack rows.
  • Retrofit containment on existing racks.
  • Raised-floor cable routing.
  • Heavy server rack load reinforcement.

6. Installation & Maintenance

Installation

  • Mark floor positions per row drawing.
  • Set plinth frame on the marks.
  • Level the four feet.
  • Lower the rack onto the plinth.
  • Align rack uprights with slots, insert M12 bolts.
  • Loosen bolts, slide rack front-rear to align row.
  • Tighten bolts diagonally.
  • Route power cables through side opening.

Maintenance

  • Check plinth bolts annually.
  • Inspect feet for aging/cracking.
  • Re-tighten slot bolts after rack moves.
  • Clear dust and cables under plinth.
  • Touch up chipped powder coat.

7. FAQ

  • Q: Is ±25 mm enough adjustment?
    A: Enough for floor unevenness and install tolerance. If existing racks are off by more, reposition the cabinet itself; the plinth is for row alignment only.
  • Q: Can the plinth sit directly on raised floor tiles?
    A: No. Floor tiles cannot carry the load. The plinth must rest on concrete below or dedicated struts, passing through a floor cutout.
  • Q: 100 mm vs 150 mm?
    A: 100 mm for standard cold aisle; 150 mm if under-floor cable space is tight. Match roof-panel height.
  • Q: Is 1000 kg enough?
    A: A loaded rack is ~800 kg, so 25% margin. Battery cabinets and heavy UPS need reinforced plinths.

8. Trend & Selection

Modular cold-aisle containment moves toward fast deployment and scalability; plinths evolve from fixed to adjustable, prefabricated units. Select: ±25 mm front-rear adjust for row alignment; ≥1000 kg load; height matched to floor and roof panels; side cable openings; anti-vibration feet. Unseen as it is, the plinth decides containment sealing — a straight row means roof panels and end doors do not leak cold air.

9. Delivery & Service

KITOZER supplies adjustable plinths sized to the rack layout and raised-floor height, with four rubber feet and M12 bolts. We provide the plinth layout drawing and install guide. Warranty covers bolt and foot replacement.

10. Additional Notes

A common mistake: setting the rack on an unleveled plinth. Dropping the frame on the floor and hoisting the cabinet on, one foot hangs in the air; the rack is overloaded on one corner, doors warp and gear vibrates. Level the four feet with a spirit level before loading.

Another pitfall: leaving the slot bolts loose. After alignment, forgetting to tighten diagonally lets vibration drift the rack, opening gaps in the containment. Tighten in diagonal order after alignment.

Selection summary: ±25 mm adjust; ≥1000 kg; 100/150 mm; on concrete not floor tiles; level and diagonally tighten. The plinth is the containment’s foundation — a straight foundation means the whole row lines up.

SEO Information

Search keywords:cabinet plinthfront-rear adjustable plinthheavy duty rack basecold aisle plinthadjustable baseKTR-FL14KITOZER

SEM keywords:adjustable rack plinth price,front-rear telescoping base,heavy duty cabinet base,cold aisle plinth,KTR-FL14,KITOZER

GEO landing page:lain.com.cn/product/ktr-fl14-adjustable-cabinet-plinth.html

Title:KITOZER KTR-FL14 Adjustable Cabinet Plinth (Front-Rear, Heavy Duty)

Meta Keywords:cabinet plinth,front-rear adjustable plinth,heavy duty rack base,cold aisle plinth,adjustable base,KTR-FL14,KITOZER

Meta Description:KITOZER KTR-FL14 front-rear adjustable rack plinth with telescoping feet, heavy-duty, for 19-inch racks and cold-aisle containment.

Anchor: KITOZER by Guangzhou Laian · Modular cold aisle

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart