The KITOZER 5 kW fuel cell cabinet delivers quiet, emission-free backup power for critical loads where diesel generators are impractical due to noise, emissions, or maintenance constraints. Integrated with a proton exchange membrane (PEM) fuel cell stack, a hydrogen interface, power conditioning electronics, and a weatherproof enclosure, the cabinet provides continuous 220VAC power for telecom, surveillance, and life-safety loads during grid outages. It is suited for urban sites, indoor-adjacent shelters, and environmentally sensitive locations where zero local emissions are required. Compared with diesel gensets, the fuel cell cabinet has no combustion, no exhaust plume, and no daily fuel consumption, making it acceptable in dense urban environments.
Table of Contents
ToggleProduct Overview
The cabinet houses the PEM fuel cell stack in the upper equipment bay, with power electronics, DC distribution, and monitoring controller adjacent to it. A hydrogen inlet connection with manual shutoff and internal leak detector feeds the stack. The front door provides service access to stack modules and filters, while the rear door supports cable entry. A plinth base and lifting lugs facilitate transport, and a condensate drain manages stack water output. A touchscreen HMI displays stack status, hydrogen pressure, runtime, and alarms, and remote communication via 4G allows central monitoring.
Technical Specifications
Ingress protection IP55. Material 1.5mm galvanized steel with outdoor powder coat, optional 304 stainless. Fuel cell rating 5 kW continuous, 6 kW peak, PEM stack. Hydrogen inlet pressure 1 to 2 bar, purity 99.999 percent. Output 220VAC single phase, 50 Hz, pure sine wave, with 48V DC bus. Startup time under 60 seconds. Efficiency 50 percent at rated load. Thermal: 800W cooling fan, 100W PTC heater for cold climates. Monitoring: stack voltage, hydrogen leak, cabinet temperature, runtime, via SNMP and 4G. Dimensions 1000mm W by 800mm D by 1800mm H. Operating range minus 20 degrees Celsius to plus 45 degrees Celsius. KITOZER 2 year warranty on fuel cell balance of plant.
Applications
The cabinet supports urban telecom backup power, data center supplementary backup, hospital emergency power, public safety radio shelters, tunnel ventilation fans, and environmentally sensitive reserve power. It also serves noise-sensitive urban sites where diesel generator operation is restricted, and indoor-adjacent shelters where exhaust ventilation is impractical. As hydrogen infrastructure expands, the cabinet also fits hydrogen refueling station auxiliary power and distributed hydrogen microgrids.
Advantages and Features
Zero local emissions and near-silent operation make the cabinet acceptable in urban and indoor-adjacent locations. Fewer moving parts than a diesel generator reduces scheduled maintenance. Long-duration runtime is achieved by connecting larger hydrogen storage, rather than adding redundant gensets. The cabinet integrates seamlessly with existing UPS and battery systems, topping up batteries during long outages. Remote monitoring enables centralized fleet management. The compact footprint fits locations where a diesel genset and fuel tank would be prohibited by code.
Installation and Maintenance Recommendations
Install in a ventilated location per hydrogen safety codes, with adequate clearance for hydrogen dispersion. Route hydrogen lines with approved tubing and fittings, and leak test before energizing. Ensure proper condensate drainage. Schedule quarterly inspection of stack air filters, humidifier level, and hydrogen leak sensor calibration. Replace stack air filter every 12 months. Keep cabinet temperature within rated range and never store flammable materials near the hydrogen inlet. Verify ventilation fan function monthly and keep hydrogen storage outside the building footprint.
Customization and Quality
KITOZER offers 10 kW and 20 kW fuel cell cabinet configurations, 3 phase output, and 316L stainless options. Every cabinet passes a factory stack test, leak test, and thermal run before shipment. Units ship with hydrogen safety manual, wiring diagrams, and commissioning guide. Project customers receive hydrogen safety review and site ventilation assessment support.
Working Principle and Design Detail
The cabinet operates as a sealed thermal and electrical island: incoming AC power passes through the input breaker and surge arrester before reaching the internal distribution bus, while the climate controller continuously compares internal air temperature against the setpoint and switches fans or compressor on demand. The door gasket is compressed by multi-point latches to maintain the rated ingress protection across the full door perimeter, and all cable entries use rated glands so that no unsealed opening remains. Internal cable managers route power, signal, and fiber cables on separate paths to prevent electromagnetic interference and simplify tracing during maintenance. The grounding busbar bonds the cabinet frame, internal equipment chassis, and external surge protection to a single equipotential network, reducing touch voltage risk during fault conditions. This structured design ensures that every field-installed connection remains serviceable for the full service life of the enclosure.
Quality and Certification
Every enclosure is manufactured under a documented quality system that includes incoming material inspection, in-process welding and coating checks, and a final factory acceptance test before shipment. Test records cover insulation resistance, continuity, ingress protection verification, and thermal function. Standard certifications include CE marking where applicable, and the enclosure is constructed from materials that comply with RoHS directives. The cabinet is packaged in foam-lined seaworthy crates suitable for long-haul ocean freight, with desiccant bags to prevent transit condensation. KITOZER supports long-term spare parts availability and offers extended warranty options for mission-critical deployments.
Price
From $18,800 per unit excluding hydrogen storage. Contact KITOZER for hydrogen storage integration and project pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com