ToggleProduct Overview
The KITOZER galvanized sheet air duct system is a prefabricated rectangular duct network designed to supply conditioned air from CRAH/CRAC units or air handlers to cold aisles, and to return hot exhaust air from contained hot aisles back to cooling equipment. Built from 1.0 to 1.2mm galvanized steel with flange connections, the ductwork handles typical data center airflow volumes from 1000 CFM to 10000 CFM per branch. The system includes straight sections, elbows, tees, reducers, volume dampers, flexible connectors, and diffuser grilles, all factory-cut and slip-flanged for fast on-site assembly. KITOZER provides duct sizing calculations based on required face velocity, static pressure, and noise targets, ensuring the air distribution network balances airflow across all containment aisles.
Poorly designed ductwork wastes fan energy, creates noise, and leaves some aisles starved for cold air. KITOZER engineers each branch using velocity pressure tables, keeping main duct velocity below 10 m/s and branch velocity below 6 m/s to control noise. Volume dampers at every branch allow commissioning contractors to balance airflow so each containment aisle receives its design CFM regardless of distance from the AHU. KITOZER also provides pressure drop calculations and noise estimates so the mechanical engineer can verify the ductwork will not introduce acoustic complaints in adjacent offices.
Technical Specifications
Material: galvanized steel DX51D Z120, 1.0 to 1.2mm thickness. Standard sizes: 300×200, 400×200, 500×300, 600×400, 800×500, 1000x500mm rectangular. Air volume per branch: 1000 to 5000 CFM. Velocity: 6 to 10 m/s in main duct, 3 to 5 m/s at diffusers. Static pressure: up to 1500 Pa. Joint: TDC flange with gasket, bolted. Insulation option: 25mm rubber foam or rock wool, foil faced. Dampers: opposed-blade galvanized volume dampers with quadrant handle. Flexible connector: canvas or silicone, 200mm long. Diffuser: aluminum swirl or linear grille with opposed blades. Fire rating: galvanized steel Class A. CE, RoHS. KITOZER brand, 5 year warranty on ductwork.
Applications
The galvanized duct system is used in data centers without raised floors, in rooftop packaged air handler installations, in hot aisle containment return air networks, in lab clean rooms, in industrial process cooling rooms, and in museum and archive climate control. Typical deployments include enterprise data halls, colocation facilities, telecommunications central offices, hospital IT suites, university HPC rooms, and industrial SCADA control rooms. The ductwork also connects CRAC units to overhead cold aisle chimneys and returns hot exhaust to air-cooled chillers on the roof. In offices and retail spaces, it distributes conditioned air from rooftop DOAS units to ceiling diffusers.
Key Advantages
First, precise airflow balance: volume dampers at every branch allow commissioning to deliver design CFM to each aisle. Second, low leakage: flange-gasketed joints keep leakage below 3 percent. Third, corrosion resistance: galvanized steel withstands humid data hall environments. Fourth, fast installation: pre-fabricated slip-flanged sections reduce on-site labor. Fifth, acoustic control: lined sections and flexible connectors attenuate fan noise. Sixth, scalability: additional branches can be added using standard tees and reducers. Seventh, compatibility with VAV boxes and EC fan arrays. Eighth, smooth internal finish reduces pressure drop and dust accumulation.
Customization Options
KITOZER offers insulated duct sections in 25mm rubber foam or 50mm rock wool with aluminum cladding for hot and cold ducts. Optional accessories include motorized volume dampers with BMS control, fire dampers rated 70 degrees Celsius, acoustic lined duct sections for noise-sensitive areas, and stainless steel flanges for coastal corrosive environments. Custom duct sizes and flat oval sections are available for tight ceiling spaces.
Installation and Maintenance
KITOZER provides layout drawings, duct isometrics, and a bill of materials. Mechanical contractors hang ductwork on threaded rods, connect sections with flange gaskets, install volume dampers at branches, and balance airflow with a velometer during commissioning. Insulated duct sections should be wrapped with foil tape to prevent condensation. Maintenance includes annual inspection of gaskets and hangers, semi-annual damper operation check, and diffuser cleaning every 2 years. KITOZER supplies replacement gaskets, dampers, and diffusers on request, backed by a 5-year warranty on the ductwork.
Warranty and Global Support
KITOZER provides layout drawings, duct isometrics, and a bill of materials with every duct order. The ductwork carries a 5-year warranty against manufacturing defects. Replacement gaskets, dampers, diffusers, and flexible connectors are held in regional stock. KITOZER also offers on-site commissioning support and a long-term maintenance contract covering annual hanger inspection, damper testing, and diffuser cleaning.
Price
From $12,500 per complete 2000 CFM duct network (100 kg galvanized duct, dampers, diffusers, flexible connectors, gaskets). Contact +86 13922289957 for project-based quotation with layout drawing.