KITOZER Galvanized Steel Air Duct System For Data Center

KITOZER galvanized steel air duct system distributes conditioned supply air from computer room air handlers (CRAH) to contained cold aisles, or returns hot exhaust from contained hot aisles to cooling units. Fabricated from 1.0 to 1.5 mm galvanized sheet with flanged connections, the ductwork is engineered for low leakage, low vibration, and long service life in 24/7 data center environments. The system includes straight sections, elbows, tee branches, reducers, volume control dampers, flexible connectors, and insulation jackets where duct runs pass through non-conditioned spaces. It is sized for airflow velocities between 6 and 10 meters per second, keeping fan noise below NR 35 in occupied aisles.

Product Overview

Many data centers rely on raised floor plenum as the supply path, but when floor height is limited, rack density is high, or containment is used, ducted supply becomes more efficient. KITOZER ductwork replaces the plenum with a purpose-built air path that delivers exact CFM to each aisle. Supply ducts drop from the ceiling to the containment roof adapter, and return ducts carry hot air from hot aisle containment back to CRAH units. Every joint is flanged with EPDM gaskets, and every branch has a balancing damper so the commissioning engineer can tune airflow to each aisle. The duct can be internally lined with acoustic insulation or externally wrapped with 25 mm elastomeric foam to prevent condensation in humid climates.

Technical Specifications

Material: galvanized steel, zinc coating Z120 standard, Z275 optional for coastal sites. Sheet thickness: 1.0 mm for rectangular ducts up to 1000 mm, 1.2 mm up to 1500 mm, 1.5 mm above. Standard sizes: 400 x 200, 600 x 300, 800 x 400, 1000 x 500, 1200 x 600 mm. Flange: T30 angle iron, M8 bolts every 150 mm. Gasket: closed cell EPDM, 5 mm thickness. Air leakage: class C per EN 12237, below 3 percent at 1000 Pa. Maximum working pressure: 1500 Pa. Velocity range: 4 to 12 m/s. Insulation: 25 mm closed cell elastomeric foam, self adhesive, vapor sealed. Fire rating: duct shell non-combustible, insulation B-s1, d0. Accessories: opposed blade volume dampers, fabric flexible connectors 300 mm long, access doors 300 x 300 mm, and turning vanes in elbows.

Applications

This ductwork is used in data centers that use overhead supply instead of raised floor plenum, in facilities where floor height is less than 600 mm, and in high density halls that need ducted cold air to contained aisles. It is also used in hot aisle containment returns, in liquid cooling secondary loops air handlers, and in emergency smoke extraction systems. Typical projects include colocation expansions, enterprise on-premise data centers, telecom core rooms, and modular data centers where the CRAH sits outside the white space. It pairs with variable frequency drive fans, chillers, and free cooling units to deliver exact temperature and humidity at each rack.

Advantages and Features

Galvanized steel ductwork outperforms fabric or flexible ducting in every dimension: it does not sag, does not absorb dust, does not off-gas, and does not wear out from fan vibration. Flanged joints are leak tight, balancing dampers allow tuning, and the system can be extended or modified without replacing runs. External insulation prevents condensation in humid climates, which is a common failure mode in uninsulated metal ducts. The rectangular flat shape also fits tight ceiling spaces better than round duct. Because every section is prefabricated to drawing, on-site installation is fast and predictable. Finally, galvanized steel is fully recyclable and meets green building credit requirements for recycled content.

Installation and Maintenance

Duct sections are delivered in crates with identification tags matching the installation drawing. A two person crew hangs sections from the ceiling using threaded rod and spring hangers at 1.5 meter spacing. Flanges are bolted with gasket between. Flexible connectors isolate fan vibration. After installation, the system is pressured to 1.5 times working pressure and leakage measured. Balancing dampers are adjusted per the commissioning report. Maintenance is annual: inspect gasket joints for sagging or gaps, check hangers for corrosion, and verify that balancing damper positions match the original report. Access doors allow internal inspection and cleaning. Replacement sections are fabricated to order and ship within one week.

Warranty and Support

KITOZER warrants the ductwork for 5 years against material defects and leakage at flanged joints. The factory produces shop drawings based on the customer HVAC layout, marks every section with a unique tag, and ships a complete installation manual in English. Commissioning engineers are available on site to balance airflow and verify leakage, if required. Replacement sections are fabricated to drawing within one week, and gaskets, dampers, and access doors are stocked as standard spare parts. The ductwork is fully recyclable at end of life, supporting green building credits for the project.

Price

From $65 per square meter of duct surface, including flanges, gaskets, and hangers. Insulation and accessories quoted separately. Contact +86 13922289957 for a takeoff based on drawings.