The KITOZER DN20 brass discharge nozzle is the final distribution component of a clean-agent gas fire suppression system, responsible for converting high-velocity agent flow from the piping into an evenly distributed spray that fills the protected room at design concentration. The nozzle is precision machined from forged brass with multiple outlet orifices sized to produce the characteristic umbrella pattern used in FM200, IG541, and FK-5-1-12 systems. Each nozzle is flow tested at the factory and delivered with a stamped flow number that engineers use during hydraulic calculation.
The nozzle orifice design is critical, because too small an orifice creates excessive pressure drop and too large an orifice wastes agent in one corner of the room. KITOZER engineers size each nozzle based on the room geometry, ceiling height, and required discharge time, so the agent reaches every corner within the 10-second window. The nozzle body is hex shaped for wrench installation, and the orifice plate is removable for cleaning if debris enters the pipe. The chrome-plated finish resists tarnishing in conditioned rooms.
Technical Specifications
Connection thread R3/4 inch BSPT, body material forged brass HPb59-1, orifice configuration 6 holes of calibrated diameter, working pressure 6 MPa, flow coefficient K value 0.5 to 3.0 depending on orifice size, finish chrome plated, mounting orientation vertical down or horizontal, maximum coverage area 15 square meters per nozzle at design concentration. CCCF certified, GB 25972 compliant. Supplied with plug protector and identification tag.
The nozzle body is machined from a single brass forging, with a 6-hole orifice pattern drilled on a precision CNC machine. Each orifice is laser measured, and the flow coefficient is stamped on the hex flats. The nozzle is rated for 6 MPa working pressure, which covers the 4.2 MPa FM200 system with margin. The chrome plating is 5 microns thick, applied after polishing, and provides a bright finish that resists fingerprints. The protective plastic plug stays on until final commissioning, preventing dust and insects from entering the orifice. Each nozzle ships with a stainless steel identification tag engraved with the flow number and project zone.
Application Scenarios
This nozzle is installed on the ceiling or upper wall of protected rooms such as data center server halls, electrical switchgear rooms, UPS rooms, battery rooms, process control panels, library vaults, museum display cases, and telecommunications shelters. Multiple nozzles are distributed to ensure uniform agent concentration within 10 seconds of discharge, and the number of nozzles is sized based on room volume, ceiling height, and agent design concentration. KITOZER supplies nozzles in DN15, DN20, DN25, and DN32 sizes to match the pipe layout designed by the fire protection engineer.
For a typical 200 square meter server hall, 6 to 8 nozzles are distributed in two rows along the ceiling, each sized to deliver 20 to 30 kg of agent. For battery rooms, nozzles are placed above each battery rack to ensure direct agent delivery. For cable tunnels, nozzles are installed every 6 meters along the tunnel ceiling. For museum display cases, micro-nozzles with flow numbers under 0.5 are used to avoid damaging artifacts. KITOZER provides a nozzle placement drawing service based on the room ceiling layout, including beam and duct interference checks.
Key Advantages
The calibrated orifices ensure repeatable discharge performance from nozzle to nozzle, eliminating the concentration hot and cold spots that occur with generic nozzles. The brass body resists corrosion from long-term exposure to conditioned room air, and the chrome finish prevents discoloration. Each nozzle ships with a flow number stamped on the hex flats, so the installer can confirm the correct nozzle is fitted at each location. KITOZER also provides a nozzle placement drawing service based on room geometry, reducing design time for the system integrator.
The removable orifice plate allows the nozzle to be cleaned after a discharge, rather than discarded. The brass body is fully recyclable at end of life. The nozzle is compatible with FM200, IG541, and FK-5-1-12 agents, so one stock covers multiple project types. KITOZER tests every nozzle on a flow bench before shipment, verifying the K-factor within plus or minus 5% of the stamped value. The CCCF certificate covers the complete nozzle range, so the project engineer does not need separate certification for each size.
Installation and Maintenance Recommendations
Install nozzles perpendicular to the ceiling, with the deflector 100 to 200 mm below the finished slab, and keep a clear radius of at least 500 mm around each nozzle to avoid beam or duct interference. Tighten with a wrench on the hex flats, never grip the orifice plate. Remove the protective plug only immediately before final system pressure testing to prevent debris entering the orifice. Inspect nozzles annually for dust, paint overspray, or mechanical damage, and replace any nozzle with a blocked orifice. Keep two spare nozzles of each flow number on site for immediate replacement after discharge.
After any discharge, remove the nozzle and inspect the orifice for soot or debris, and blow through with compressed dry air. Do not paint the nozzle, because paint can clog the calibrated orifices. If the nozzle is accidentally painted, replace it immediately. Keep a record of the flow number installed at each location on the nozzle layout drawing, so the correct replacement can be ordered. KITOZER recommends a 10-year replacement cycle for nozzles, because the orifice can erode over multiple discharges. Spare nozzles should be stored in their original plastic plugs in a dry cabinet.