KITOZER
KITOZER

KITOZER Gas Nozzle: DN20 Brass FM200 Discharge Nozzle

Product Overview

The KITOZER DN20 brass discharge nozzle is the final distribution component of a clean-agent gas fire suppression system, responsible for converting high-velocity agent flow from the piping into an evenly distributed spray that fills the protected room at design concentration. The nozzle is precision machined from forged brass with multiple outlet orifices sized to produce the characteristic umbrella pattern used in FM200, IG541, and FK-5-1-12 systems. Each nozzle is flow tested at the factory and delivered with a stamped flow number that engineers use during hydraulic calculation.

Technical Specifications

Connection thread R3/4 inch BSPT, body material forged brass HPb59-1, orifice configuration 6 holes of calibrated diameter, working pressure 6 MPa, flow coefficient K value 0.5 to 3.0 depending on orifice size, finish chrome plated, mounting orientation vertical down or horizontal, maximum coverage area 15 square meters per nozzle at design concentration. CCCF certified, GB 25972 compliant. Supplied with plug protector and identification tag.

Application Scenarios

This nozzle is installed on the ceiling or upper wall of protected rooms such as data center server halls, electrical switchgear rooms, UPS rooms, battery rooms, process control panels, library vaults, museum display cases, and telecommunications shelters. Multiple nozzles are distributed to ensure uniform agent concentration within 10 seconds of discharge, and the number of nozzles is sized based on room volume, ceiling height, and agent design concentration. KITOZER supplies nozzles in DN15, DN20, DN25, and DN32 sizes to match the pipe layout designed by the fire protection engineer.

Key Advantages

The calibrated orifices ensure repeatable discharge performance from nozzle to nozzle, eliminating the concentration hot and cold spots that occur with generic nozzles. The brass body resists corrosion from long-term exposure to conditioned room air, and the chrome finish prevents discoloration. Each nozzle ships with a flow number stamped on the hex flats, so the installer can confirm the correct nozzle is fitted at each location. KITOZER also provides a nozzle placement drawing service based on room geometry, reducing design time for the system integrator.

Installation and Maintenance Recommendations

Install nozzles perpendicular to the ceiling, with the deflector 100 to 200 mm below the finished slab, and keep a clear radius of at least 500 mm around each nozzle to avoid beam or duct interference. Tighten with a wrench on the hex flats, never grip the orifice plate. Remove the protective plug only immediately before final system pressure testing to prevent debris entering the orifice. Inspect nozzles annually for dust, paint overspray, or mechanical damage, and replace any nozzle with a blocked orifice. Keep two spare nozzles of each flow number on site for immediate replacement after discharge.

Price

From $28 per nozzle. Contact +86 13922289957 for gas suppression nozzle pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top