Table of Contents
ToggleProduct Overview
The KITOZER GCK withdrawable low voltage switchgear is a motor control center and distribution panel built for industrial plants, water treatment, HVAC plants, and manufacturing lines where individual feeders must be withdrawn for maintenance without shutting down the whole switchboard. The drawer type functional units accept molded case breakers, contactors, soft starters, or variable frequency drives. A 630 A incoming section with multiple feeder drawers gives flexible, reliable power distribution. The segmented busbar chamber and withdrawable mechanism provide high safety and easy maintenance.
The GCK frame is a modular steel skeleton with vertical busbar at the rear, horizontal busbar at the top, and drawer compartments at the front. Each drawer unit is self aligned with silver plated contacts, and can be inserted, withdrawn, or isolated with a lever. Mechanical interlocks prevent withdrawal under load and prevent insertion into a live circuit unless the breaker is off. The drawer height modules (1E, 2E, 4E) accommodate different device sizes. Cable entry is from the bottom rear. The panel is designed for indoor installation and can be extended with additional sections on site.
Technical Specifications
Rated voltage 400 V three phase four wire, rated current incoming 630 A, busbar 1000 A. Peak withstand 50 kA, short time withstand 30 kA for 1 second. Drawer units 1E, 2E, 4E height modules: molded case breaker 63 A to 250 A, contactor 9 A to 100 A, VFD or soft starter up to 75 kW. Self aligning contacts, interlock mechanism preventing withdrawal under load. Enclosure IP40 front. Internal arc fault resistant design. Busbar compartment, cable compartment, and drawer compartment separated. Complies with IEC 61439-2, GB/T 7251.1.
Each drawer unit contains its own mini circuit breaker or molded case breaker, control fuse, contactor or soft starter, and terminals for motor cables. Control wiring is pre assembled in the drawer and plugs into the vertical busbar and control circuit contacts. The incoming section contains a 630 A air circuit breaker with electronic release, current transformers, and metering. Optional intelligent motor protection relays provide communication over Modbus or Profibus for SCADA integration. The vertical busbar is rated 1000 A and runs through each section.
Application Scenarios
GCK motor control centers serve water treatment pumps, HVAC chillers and fans, conveyor lines, machine tool feeders, packaging machines, and building automation. Withdrawable drawers allow a faulty feeder to be pulled out and replaced with a spare drawer in minutes, minimizing production downtime. The 630 A rating suits small to medium plants fed from 800 kVA or 1000 kVA transformers. Multiple sections can be bolted to form a large MCC line with incoming, bus tie, and motor feeders.
In water treatment plants, GCK panels control raw water pumps, chemical dosing pumps, and blower motors. In HVAC plants, they manage chillers, cooling towers, and air handling units. In manufacturing lines, they feed conveyors, mixers, and packaging machines. In machine shops, they supply tool motors and auxiliary equipment. For building automation, they control lighting panels and fan coil units. The withdrawable design is essential where 24/7 operation is required and downtime must be minimized. Spare drawers can be kept on site, allowing a faulty unit to be swapped in minutes while the failed drawer is repaired in the workshop.
Advantages
Withdrawable drawers reduce maintenance time. Standardized spares inventory. Interlock prevents live withdrawal. Segregated compartments improve arc fault safety. Modular arrangement allows future expansion without replacing existing panels. Front operation and rear cable access. Contact wear indicator. Five year warranty. Drawers can be populated with soft starters or variable frequency drives for motor speed control, and the control wiring plugs into the vertical busbar, making motor change outs straightforward.
Installation and Maintenance
Install on a level plinth, bolt sections together. Keep 1.5 m front for drawer withdrawal and 0.8 m rear for cable. Connect incoming busbar, branch cables, and ground. Verify drawer numbering and breaker settings. Maintenance quarterly: inspect drawer contacts, lubricate mechanism. Annually: torque busbar, insulation test, breaker trip test. Keep drawers in fully inserted position unless serviced. Do not force a drawer that does not seat; check interlock and contacts. Spare drawers should be stored in their packaging until needed, and contact surfaces should be inspected before insertion.
Price
From $14,200 per section including 630 A incoming breaker and 16 drawer units. Custom drawer mix and VFD integration are optional. KITOZER can provide a single line diagram and drawer schedule tailored to each motor and feeder load, along with factory test reports and wiring diagrams.