ToggleProduct Overview
The KITOZER GCK withdrawable low voltage switchgear is a motor control center and distribution panel built for industrial plants, water treatment, HVAC plants, and manufacturing lines where individual feeders must be withdrawn for maintenance without shutting down the whole switchboard. The drawer type functional units accept molded case breakers, contactors, soft starters, or variable frequency drives. A 630 A incoming section with multiple feeder drawers gives flexible, reliable power distribution. The segmented busbar chamber and withdrawable mechanism provide high safety and easy maintenance.
Technical Specifications
Rated voltage 400 V three phase four wire, rated current incoming 630 A, busbar 1000 A. Peak withstand 50 kA, short time withstand 30 kA for 1 second. Drawer units 1E, 2E, 4E height modules: molded case breaker 63 A to 250 A, contactor 9 A to 100 A, VFD or soft starter up to 75 kW. Self aligning contacts, interlock mechanism preventing withdrawal under load. Enclosure IP40 front. Internal arc fault resistant design. Busbar compartment, cable compartment, and drawer compartment separated. Complies with IEC 61439-2, GB/T 7251.1.
Application Scenarios
GCK motor control centers serve water treatment pumps, HVAC chillers and fans, conveyor lines, machine tool feeders, packaging machines, and building automation. Withdrawable drawers allow a faulty feeder to be pulled out and replaced with a spare drawer in minutes, minimizing production downtime. The 630 A rating suits small to medium plants fed from 800 kVA or 1000 kVA transformers. Multiple sections can be bolted to form a large MCC line with incoming, bus tie, and motor feeders.
Advantages
Withdrawable drawers reduce maintenance time. Standardized spares inventory. Interlock prevents live withdrawal. Segregated compartments improve arc fault safety. Modular arrangement allows future expansion without replacing existing panels. Front operation and rear cable access. Contact wear indicator. Five year warranty.
Installation and Maintenance
Install on a level plinth, bolt sections together. Keep 1.5 m front for drawer withdrawal and 0.8 m rear for cable. Connect incoming busbar, branch cables, and ground. Verify drawer numbering and breaker settings. Maintenance quarterly: inspect drawer contacts, lubricate mechanism. Annually: torque busbar, insulation test, breaker trip test. Keep drawers in fully inserted position unless serviced. Do not force a drawer that does not seat; check interlock and contacts.
Price
From $14,200 per section including 630 A incoming breaker and 16 drawer units. Custom drawer mix and VFD integration are optional.