Table of Contents
ToggleProduct Overview
The KITOZER GCS low voltage withdrawable switchboard is a modular metal enclosed distribution board rated 400V AC for industrial power distribution, commercial building mains, and data center LV switchgear. Each GCS panel combines a vertical busbar system with withdrawable functional units (feeder, motor control, capacitor compensation) that slide out on guide rails for maintenance without shutting down the main bus. KITOZER builds the GCS sheet steel cubicle with segmented compartments to reduce arc flash energy and to allow future circuit additions by simply plugging in a new module.
Technical Specifications
Rated voltage 400V three phase four wire, 50Hz. Rated current up to 3200A main bus, vertical bus 1000A per section. Short time withstand 50kA for 1 second, peak 105kA. Functional units: feeder MCCB 16A to 630A, motor starter with contactor and thermal overload, capacitor switching contactor or thyristor. Withdrawable unit position: connected, test, disconnected, with mechanical interlock. Protection degree IP30 front, IP2X rear. Panel width 800mm or 1000mm, depth 1000mm, height 2200mm. Standards IEC 61439-1 and -2, GB 7251, CE.
Application Scenarios
GCS switchboards are used in industrial plant LV mains, water pump stations, HVAC plants, commercial building distribution, and data center main switchboards. The withdrawable design is preferred in continuous process plants where feeder shutdowns must be minimized. It also supports large motor control centers with dozens of motor starters.
The GCS can also be configured as a capacitor compensation panel, ATS panel, or motor control center within the same frame. The withdrawable units allow a feeder circuit to be swapped from MCCB to contactor starter in minutes, without shutting down the main bus. The copper busbar is silver plated at joints to reduce contact resistance and heating. KITOZER offers a power meter on each feeder with Modbus communication, allowing energy monitoring per circuit. The panel is type tested to IEC 61439, ensuring internal arc withstand and temperature rise limits.
Advantages and Features
Modular functional units allow rapid reconfiguration. Arc resistant internal separation reduces personnel risk. KITOZER offers options including a power meter on each feeder, harmonic measurement, RS485 Modbus communication, and a 7 inch HMI at the main incoming panel. The copper busbar is silver plated at joints. Factory assembly and routine tests include dielectric, contact resistance, and insulation resistance.
Installation and Maintenance
Install panels on a flat concrete floor with front and rear walkways of at least 1000mm. Join panels with provided bolts and connect the horizontal busbar with torque controlled joints. Bond each cubicle to the building earth grid. Commissioning includes insulation resistance on each feeder, MCCB trip test, and protection coordination check. Annual maintenance includes torque check on busbar joints, contactor contact inspection, and heater element test. KITOZER recommends infrared thermography of busbar under full load.
Construction and Quality Assurance
The GCS cabinet is fabricated from 2.5mm cold rolled steel with a powder coated finish. The horizontal copper busbar is silver plated at joints and rated for 3200A continuous. The vertical busbar is rated for 1000A per section. Each withdrawable unit has connected, test, and disconnected positions with mechanical interlocks. Every panel passes a power frequency withstand test, a contact resistance test, and an insulation resistance test. KITOZER provides a type test certificate and FAT report. The modular frame allows future feeder additions without replacing the whole board.
Packaging and After Sales
Panels are shipped assembled on a steel skid. KITOZER provides commissioning support. The 2 year warranty covers busbar, breakers, and feeder units. Spare MCCBs, contactors, and auxiliary contacts are stocked. For industrial plants, KITOZER offers a spare withdrawable unit for rapid swap.
KITOZER offers a range of optional extras including a 7 inch HMI at the main incoming panel, a power meter on each feeder, harmonic measurement, and an arc fault detection system. The panel can be configured as a main switchboard, a distribution board, or a motor control center. The 800mm width allows installation in existing switchrooms. The copper busbar is sized for future expansion, so additional feeder cubicles can be added later without replacing the main busbar.
The 2 year warranty covers busbar, breakers, and feeder units. For continuous process plants, KITOZER offers a spare withdrawable unit for rapid swap and a 5 year extended warranty.
Price
From $1,980/panel. Contact +86 13922289957 for GCS switchboard pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com