KITOZER 2V 500Ah gel battery is a deep-cycle valve-regulated lead-acid battery using silica gel immobilized electrolyte. The gel formulation eliminates stratification, enables deep discharge recovery, and provides excellent cyclic life compared with flooded and AGM batteries. It is designed for solar off-grid systems, telecom base stations, and long-runtime UPS installations where frequent or deep discharge cycles are expected.
Table of Contents
ToggleProduct Overview
The 2V 500Ah cell delivers 1000 watt-hours of nominal energy. Tubular positive plates provide deep-cycle durability, and the gel electrolyte eliminates free liquid acid, enabling safe operation in any orientation. The rugged ABS container and copper alloy terminals support high current discharge. Each cell includes a safety vent and is factory-tested for capacity and internal resistance.
The gel electrolyte immobilizes the acid in a silica gel matrix, preventing stratification. This makes the battery ideal for cyclic applications.
The cell is designed for 3000 cycles at 80 percent DoD. The gel electrolyte eliminates stratification.
The gel electrolyte immobilizes the acid in a silica gel matrix, preventing stratification even after long periods of partial charge. This makes the battery ideal for cyclic applications such as solar off-grid systems where daily charge-discharge cycles are expected.
Technical Specifications
Nominal voltage 2V. Rated capacity 500Ah at 10-hour rate to 1.80V/cell at 25C. Internal resistance less than 0.8mOhm. Operating temperature -20C to 50C, recommended 20-25C. Float charge voltage 2.25-2.30V/cell at 25C, cycle 2.35-2.40V/cell. Max charge current 100A. Deep discharge recovery to 80 percent DoD with 3000 cycles. Self-discharge less than 2 percent per month. Dimensions 170 x 170 x 335mm, weight 31kg. CE, UL, ISO. KITOZER, 3 year warranty.
The battery ships factory-charged. Storage temperature should be between 0 and 30C.
The cell is designed for 10-hour rate discharge. The tubular positive plates provide deep-cycle durability.
Application Scenarios
This gel cell is used in solar off-grid power systems, telecom base station backup, long-runtime UPS installations, and marine applications. The deep-cycle capability makes it suitable for cyclic applications such as hybrid solar-wind systems and island microgrids. It is also specified for industrial standby and emergency power systems where long float life is required.
In telecom base stations with limited grid access, the gel battery provides reliable backup. The deep-cycle capability supports daily charge-discharge cycles.
In marine applications, the gel battery provides reliable house power. The sealed design prevents acid leakage.
In hybrid solar-wind systems, the gel cell provides reliable energy storage. The deep-cycle capability supports daily cycles.
In telecom base stations, the gel cell provides reliable backup power. The deep-cycle capability supports frequent discharge.
In solar off-grid systems, multiple 2V 500Ah cells are configured in series to match the system voltage, typically 48V, 120V, or 240V. Parallel strings achieve the required energy storage capacity. The battery is also used in telecom base stations with limited grid access.
Advantages and Features
Gel electrolyte eliminates stratification. Tubular positive plates support deep cycle life. 3000 cycles at 80 percent DoD. Wide operating temperature range. Low self-discharge. Sealed and maintenance-free.
The battery is UN38.3 certified. Each cell ships with a discharge report.
The battery is CE and UL certified. The gel electrolyte eliminates stratification.
The cell is CE, UL, and ISO certified. The 3 year warranty provides peace of mind.
Installation and Maintenance Advice
Install in a clean, ventilated room at 20-25C. Use insulated tools. Tighten terminals to recommended torque. Connect in series to match system voltage. Use battery racks rated for 31kg per cell. Perform annual capacity tests. Equalize charge every 6 months for cyclic applications.
Keep the battery room well-ventilated. Store spare cells in a cool, dry location.
Do not mix cells of different ages. Keep the battery room well-ventilated.
Tighten terminals to recommended torque. Keep the battery room well-ventilated.
Perform annual capacity tests. Equalize charge every 6 months for cyclic applications.
Do not mix cells of different ages or manufacturers. Keep the battery room well-ventilated. Store spare cells in a cool, dry location and recharge every 6 months.
Price
From $98/cell. Contact +86 13922289957 for gel battery pricing, string configuration, and solar system sizing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com