ToggleProduct Overview
The KITOZER GGD low voltage switchboard is a fixed pattern, fixed wiring distribution panel built for 0.4 kV three phase four wire systems in power plants, substations, industrial plants, and commercial building mains. The 2000 A rating serves as the main incoming panel after the distribution transformer, feeding downstream GCK, MNS, or power control centers. Steel sheet enclosure, busbar chamber, and front accessible functional units make the GGD robust and economical. It is the classic choice for general power distribution where withdrawable units are not required and fixed breakers are acceptable.
Technical Specifications
Rated current 2000 A main, rated voltage 400 V three phase four wire, rated frequency 50 Hz. Busbar rated 2000 A, peak withstand 63 kA, short time withstand 30 kA for 1 second. Main breaker choose drawer type air circuit breaker 2000 A with electronic release. Branch breakers molded case 100 A to 630 A, up to 12 outgoing ways. Enclosure IP30 front, IP40 option. Busbar tin plated copper. Panel color RAL7035. Internal components include current transformers, voltage meter, power meter, and surge protector. Complies with IEC 61439-2, GB/T 7251.1.
Application Scenarios
GGD panels are used as main distribution boards in industrial plants, power station auxiliary switchgear, water plant substations, commercial building mains, and campus distribution. Fixed wiring suits loads that do not require frequent withdrawal, such as lighting feeders, HVAC pumps, and static heating. The 2000 A main rating matches 1600 kVA or 2000 kVA transformers. Multiple GGD sections can be bolted together to form a switchboard line with incoming, metering, bus tie, and outgoing sections. Front access simplifies operation in indoor substations.
Advantages
Fixed construction reduces cost compared with withdrawable panels. Robust steel enclosure withstands industrial environment. Copper busbar rated for high short time current. Front accessible breakers allow quick maintenance without rear access. Modular section arrangement allows future extension. Standardized components simplify spare parts. Surge protection and metering included as standard. Five year warranty.
Installation and Maintenance
Install on a level concrete plinth, bolt down with foundation bolts. Keep 1.5 m front access and 0.8 m rear clearance if rear access is required. Connect main busbar from transformer, branch cables to outgoing breakers. Verify phase rotation and breaker settings before energizing. Maintenance annually: clean dust, torque busbar bolts, test breaker trip, check surge protector. Every two years: insulation resistance test, contact resistance measurement. Keep panels closed and locked. Do not open live front covers; de energize before internal work.
Price
From $6,800 per section including 2000 A main breaker, 12 outgoing ways, metering, and surge protector. Custom branch configuration and IP40 enclosure are optional.