KITOZER 30kW glycol low-temperature precision air conditioner is designed for data centers in cold regions where outdoor winter temperatures drop to minus 30 degrees C or lower. Instead of a standard direct-expansion condenser, the unit circulates a water-glycol solution through a dry cooler outdoors, capturing free cooling whenever outdoor temperature is low. The indoor unit uses a glycol coil in series with the DX circuit, allowing the controller to switch between free cooling, mixed cooling, and full mechanical cooling. This architecture protects IT loads through extreme winters while minimizing energy use.
Technical Specifications
Cooling capacity 30kW DX, free cooling capacity up to 28kW at minus 5 degrees C glycol, glycol flow 6 cubic meters per hour, glycol mix 35 percent ethylene glycol protected to minus 35 degrees C, EC airflow 9,000 cubic meters per hour, scroll compressor R410A, supply voltage 380V three phase, rated power about 11kW, dimensions 1,400 millimeters wide by 1,100 millimeters deep by 2,200 millimeters high, weight about 480kg, electric heater for sump, Modbus TCP, SNMP, CE certified, operating ambient down to minus 40 degrees C.
Application Scenarios
Glycol low-temperature units are deployed in data centers in Northeast China, Mongolia, Siberia, Northern Europe, and Canada. They suit edge PoP sites, telecom shelters, and enterprise server rooms where year-round cooling is needed but outdoor air cannot be directly introduced because of snow, dust, or security concerns.
Advantages and Features
Free cooling covers most winter load, cutting energy dramatically. Glycol loop avoids refrigerant condensation issues in extreme cold. Dry cooler fans modulate to maintain glycol temperature. Sump heater prevents freeze-up during shutdown. The controller logs free-cooling hours for reporting.
Installation and Maintenance Recommendations
Use proper glycol concentration confirmed by refractometer. Insulate outdoor piping with heat trace. Install glycol make-up tank and leak detection. Commission free-cooling setpoints against local climate. Maintenance includes annual glycol concentration test, bi-annual pump seal check, and quarterly filter replacement. Keep spare glycol and strainer on site.
Price
From $16,800 per unit. Contact KITOZER for cold-climate glycol system design.