KITOZER graphite grounding module is a cylindrical earth enhancement element filled with high carbon graphite mineral compound, designed to lower earth resistance in rocky, sandy, or high resistivity soil where conventional driven rods cannot reach acceptable values. The 500x150mm module is buried vertically in a 200mm diameter drill hole together with a copper clad steel inner electrode, and the graphite compound slowly absorbs moisture from surrounding soil to maintain a low resistance contact surface year round. Unlike chemical salt electrodes that leach away within two years, the KITOZER graphite module remains stable for more than thirty years and does not pollute groundwater. It is widely specified for mountain substations, desert telecom sites, and urban buildings where small footprint and low earth resistance are required.
Table of Contents
ToggleProduct Overview
The KITOZER module consists of a porous outer shell filled with compressed graphite powder and conductive minerals. When buried and watered, the graphite absorbs and retains moisture, forming an enlarged effective electrode surface several times larger than the copper rod alone. The internal copper clad steel rod carries fault current from the down conductor to the graphite body, and the graphite body distributes current evenly into surrounding soil. The module is non-corrosive, non-toxic, and approved for use near drinking water wells because no sodium chloride or calcium chloride leaches into the ground. KITOZER supplies the module pre-filled with a water absorption pouch, so installers only need to backfill with native soil and water after installation.
Technical Specifications
Standard size: 500mm long by 150mm diameter, alternative 800x200mm for extreme resistivity. Active ingredient: high purity carbon graphite, pH neutral. Internal electrode: copper clad steel rod 14.2mm, extends 300mm above module for tape clamp connection. Module body resistance: less than 0.05 ohm. Effective contact area: 3 to 5 times same diameter copper rod. Moisture retention: absorbs up to 40 percent of body weight in water. Operating temperature: minus 40 to plus 80 degrees Celsius. Design life: more than 30 years in soil resistivity up to 2000 ohm m. Standards: DL/T 380, GB 50057, IEEE 80. Installation depth: 0.8m below finished grade, top of module. Hole diameter: 200mm drill, backfill with native soil after watering. Weight: 8kg per module. Package: 20 modules per pallet, 160kg.
Applications
KITOZER graphite modules are deployed where driven rods alone cannot achieve the required earth resistance, such as mountain relay stations, rocky cliff substation sites, desert photovoltaic plants, rooftop equipment on high-rise buildings, and urban retrofit sites where deep excavation is not allowed. Telecom base stations use two or four modules per tower to achieve below 5 ohm earth resistance within a small compound. Data center buildings specify modules at each down conductor position to meet the 1 ohm requirement for low voltage systems. Wind turbine foundations combine modules with ring earth mats to reduce the lightning impulse resistance during a direct strike. Industrial plants use modules near instrument earth bars in corrosive soil where copper rods would corrode too quickly.
Advantages
The graphite module enlarges the effective electrode surface without needing a large excavation, so it fits in small urban plots and reduces trench cost. Unlike salt-based chemical electrodes, the module does not wash away after rain, so resistance stays stable across dry and wet seasons. The graphite is non-corrosive to the copper inner rod and will not accelerate galvanic attack. Multiple modules can be connected in parallel with buried copper tape to achieve below 1 ohm resistance even in 1000 ohm m soil. Installation is fast: a 200mm diameter drill hole, drop in module, clamp tape, backfill, water, done. The module is approved for environmentally sensitive sites because it contains no heavy metals or leachable salts.
Installation and Maintenance
Drill a 200mm diameter hole to 0.8m depth. Place the KITOZER module vertically in the hole, pour 5 liters of clean water around it to saturate the graphite, then clamp the down conductor tape to the exposed copper rod using an exothermic weld or listed mechanical clamp. Backfill with native soil in 100mm lifts, compacting each layer, and water again after backfill. Measure earth resistance after one week of stabilization. Typical single module in 500 ohm m soil reads 20 to 30 ohm, and four modules in parallel reduce below 4 ohm. Inspect the exposed rod clamp annually, and rewater the hole during extended dry seasons to maintain graphite moisture. No chemical refill is needed, unlike salt electrodes that require annual topping up.
Available Models and Custom Service
KITOZER stocks the 500x150mm graphite module with 14.2mm internal rod for immediate dispatch. The larger 800x200mm size is specified for soil resistivity above 1000 ohm m, and a 1000x250mm size is available for desert and mountain sites. KITOZER can supply modules pre-filled with the water absorption pouch, with the copper rod already extended above the body for clamp connection. For projects requiring environmental certification, KITOZER can provide leaching test reports showing the module is safe near drinking water sources. Engineering support includes soil resistivity survey interpretation, electrode array design, and expected earth resistance calculation before purchase, so customers know the expected result before excavation begins.
Price
From $85 per module for 500x150mm size. 800x200mm size from $145 each. Contact +86 13922289957 for project quotation and soil resistivity engineering support.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com