KITOZER Ground Resistance Tester 4-Wire 0-2000 Ohm Fall of Potential

Product Overview

KITOZER ground resistance tester 4-wire 0-2000 ohm is a portable battery-operated instrument for measuring earth electrode resistance, soil resistivity, and ground grid continuity using the fall-of-potential method. The instrument injects a 1kHz test current through current probes and senses the voltage drop with potential probes, eliminating interference from grid DC voltage and power frequency noise. The large LCD displays resistance, soil resistivity, and test current, and stores 99 sets of data for later download. The clamp-on option is also available for fast testing without driving probes. The tester is the reference instrument for grounding commissioning and annual inspection.

Technical Specifications

Measurement range: 0.001 to 2000 ohm, four ranges. Resolution: 0.001 ohm. Soil resistivity range: 0 to 2000 k ohm.cm. Test current: up to 20mA at 1kHz. DC voltage measurement: 0 to 100V. AC voltage rejection: 50/60Hz. Power: 8x AA batteries, 200 hours. Display: 128×64 LCD with backlight. Memory: 99 records. Interface: USB for PC download. Probes: 2 current and 2 potential, 20m leads. Ingress protection: IP65. Dimensions: 200x150x85mm. Weight: 1.2kg. Certifications: IEC 61010-1, CE. Brand: KITOZER. Warranty: 2 years. The tester also measures soil resistivity using the Wenner 4-pin method.

Application Scenarios

This tester is used by electrical contractors, utility companies, and industrial maintenance teams to commission and inspect grounding systems. It verifies substation grid resistance, building lightning protection earth electrodes, telecom tower grounds, wind turbine foundations, solar farm racking grounds, and industrial plant grids. It also measures soil resistivity for new design and locates broken ground connections. Facilities management uses it annually to meet electrical safety codes. Testing companies use it for third-party commissioning. The 4-wire method is the reference method accepted by most utilities. It is also used by insurance inspectors and electrical safety officers.

Advantages and Features

The 1kHz test frequency avoids interference from power frequency leakage, providing stable readings even near substations. The 4-wire method removes lead resistance from the measurement, critical for low-resistance grids under 1 ohm. The automatic range selection simplifies field operation. The internal memory stores readings with timestamp for report generation. The IP65 housing survives rain and dust. KITOZER testers are calibrated at the factory with traceable resistors. The backlit LCD works in dark trenches. Compared with 3-wire units, this 4-wire version measures soil resistivity and eliminates lead errors. The USB download exports CSV for compliance reports.

Installation and Maintenance Recommendations

Drive the current probe 30m from the electrode under test, and the potential probe at 62% of that distance per the fall-of-potential method. Move the potential probe plus and minus 5m to confirm the plateau. Connect the E terminal to the electrode, C to current probe, P to potential probe. Do not test during rain or wet soil within 24 hours. Record readings and compare with baseline. Clean probes after use. Store in the carry case with leads coiled. Replace batteries when the low-battery icon appears. Calibrate annually at a certified lab. Do not use on energized circuits above 50V. KITOZER provides test leads, probe hammers, and report templates.

Quality Assurance and Ordering Information

Each KITOZER tester is supplied with a calibration certificate traceable to national standards, plus a carry case, test leads, probes, and USB cable. Standard lead time is 5 days. KITOZER also supplies clamp-on ground testers, insulation resistance testers, and loop impedance testers as a complete electrical test package. Custom software for report generation is available. For export, KITOZER provides CE declaration. Samples can be shipped within 48 hours for field trial. KITOZER engineers can also provide training on fall-of-potential measurement.

Technical Tips and Field Experience

From field experience, fall-of-potential measurements are most accurate when the current probe is far from buried metal pipes or cable trays. KITOZER recommends scanning the test area for buried utilities before driving probes. If readings fluctuate, move the potential probe 5m left and right to confirm the plateau; a flat plateau indicates valid measurement. In rocky soil, use longer probe lead extensions and drive probes with a jackhammer. Record soil temperature and moisture at time of test for comparison with future readings. KITOZER field engineers can provide on-site measurement training. For large grids, KITOZER recommends testing after commissioning and again after every major expansion. KITOZER also supplies clamp-on ground testers for quick screening without driving probes. KITOZER provides calibration service for all test instruments on site.

Price

From $385 per unit including leads and probes. Contact +86 13922289957 for clamp-on variant.