KITOZER KTR-GB Grounding Busbar / Copper Bar

1. Overview

All equipment in a room must be grounded to a single busbar that bonds to the building earth electrode — that bar is the grounding busbar (equal-potential bus). Without it, uneven ground resistance across equipment creates potential differences during surges, leakage or static events, damaging interfaces and even mainboards.

The KITOZER KTR-GB busbar is T2 copper (≥99.9% pure) with tin-plating for oxidation resistance. Sizes are 30×3 mm (small rooms), 40×4 mm (mid-size) and 50×5 mm (large data centers); length is custom (common 500/1000/2000 mm), with holes drilled per rack count. Insulating supports, bolts and heat-shrink tubing are included.

Selection: cross-section by fault current (40×4 mm typical for mid rooms, 50×5 mm for large centers); length by grounding points +20% spare; surface finish (tinned for anti-oxidation, bare copper degrades). Mount inside a grounding terminal box, 200~300 mm above floor for easy wiring.

2. Key Features

Material & process

  • T2 copper ≥99.9%
  • Tin-plated, anti-oxidation
  • Conductivity ≥98% IACS
  • Hardness HV ≥80

Sizes & custom

  • 30×3 / 40×4 / 50×5 mm
  • Length 500/1000/2000 mm
  • Hole pitch custom per racks
  • Insulating supports included

Mounting & bonding

  • Insulated support mount
  • M8/M12 bolted joints
  • Flexible copper-bond straps
  • Heat-shrink insulation

3. Specifications

Item KTR-GB-S1 KTR-GB-S2 KTR-GB-S3
型号 KTR-GB-303 KTR-GB-404 KTR-GB-505
截面尺寸 30×3 mm 40×4 mm 50×5 mm
材质 T2紫铜镀锡 T2紫铜镀锡 T2紫铜镀锡
导电率 ≥98% IACS ≥98% IACS ≥98% IACS
长度 500/1000mm 1000/2000mm 2000mm可定制
螺栓孔 M8×8~20孔 M10×10~30孔 M12×20~40孔
适用场景 小机房/弱电间 中等机房 大型数据中心
接地电阻 ≤1Ω(配合接地极) ≤1Ω ≤1Ω

4. Reference Prices

KTR-GB-303 30×3 mm busbar (1 m):Reference USD 8~15 / pc (ref. CNY 60~110 at ~7.2)

KTR-GB-404 40×4 mm busbar (1 m):Reference USD 14~25 / pc (ref. CNY 100~180 at ~7.2)

KTR-GB-505 50×5 mm busbar (1 m):Reference USD 22~39 / pc (ref. CNY 160~280 at ~7.2)

Reference only; final quote depends on cross-section, length and hole count. 1-year warranty; volume pricing. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Data-center equipotential grounding.
  • UPS, distribution and precision-AC grounding.
  • Server and network rack grounding.
  • SPD (surge protector) grounding collection.
  • Backroom and fire-control room ground bars.

6. Deployment & Implementation

Installation

  • Mount in grounding box on insulated supports
  • 200~300 mm above floor
  • Rack ground wires via M8/M10 bolts
  • Main earth via ≥50 mm² flexible copper

Operations

  • Quarterly ground-resistance test (≤1 Ω)
  • Check bolt torque and oxidation
  • Reapply conductive grease if tin wears
  • Bond new equipment to busbar

7. FAQ

  • Q: Why a busbar instead of direct grounding?
    A: With many devices, direct wires to building earth differ in length and resistance, creating potential differences that damage equipment. A busbar bonds everything to one point — equipotential.
  • Q: How to pick cross-section?
    A: 30×3 mm for a few racks; 40×4 mm for 10~30 racks; 50×5 mm for >50 racks. Size by fault current and rack count — oversize rather than undersize.
  • Q: Tinned or bare copper?
    A: Bare copper oxidizes black, raising contact resistance. Tin plating stays reliable for years. Use tinned in rooms, never bare.
  • Q: What ground resistance?
    A: Combined room grounding ≤1 Ω (shared with lightning, transformer and weak-current earth); separate earth ≤4 Ω. Test after handover and keep records.

8. Trend & Selection

Data-center grounding is moving from ‘independent earth’ to ‘combined earth + equipotential bonding’, with the busbar as the core. Together with SPD and ESD-floor bonding, it forms a complete ground network. Select by room size, use tinned copper, custom-drill holes per racks, keep resistance ≤1 Ω, and test periodically.

9. Delivery & Service

KITOZER offers KTR-GB selection by cross-section (30×3/40×4/50×5 mm), length and hole count, bundled with insulating supports, bolts and flexible bonding straps. T2 copper mill certificate included. 1-year warranty; custom holes and lengths in volume.

10. Additional Notes

The #1 mistake is substituting aluminum or galvanized steel flat bar. Aluminum-copper contact causes galvanic corrosion; galvanized steel conducts only ~30% of copper. Use T2 tinned copper for room grounding.

Another pitfall is loose bolts. Torque ground bolts to spec (M8 ~8 N·m); otherwise contact resistance heats up and burns through during a surge. Check annually.

Keep ground-wire lengths similar from rack to busbar — uneven lengths create impedance differences. Do not let some racks bond at 2 m and others at 0.5 m.

Selection summary: size by room scale, use tinned copper, custom-drill holes, torque bolts, keep resistance ≤1 Ω and test regularly. The busbar is the safety baseline — never skimp.

SEO Information

Search keywords:KTR-GBKITOZERGrounding Busbar / Copper Bar

SEM keywords:grounding busbar,copper busbar,equipotential bonding,T2 copper bar,room grounding,KTR-GB,KITOZER

GEO landing page:lain.com.cn/product/ktr-gb-grounding_busbar.html

Title:KITOZER KTR-GB Grounding Busbar / Copper Bar

Meta Keywords:grounding busbar,copper busbar,equipotential bonding,T2 copper bar,room grounding,KTR-GB,KITOZER

Meta Description:KITOZER KTR-GB grounding busbar, T2 copper tinned, 30×3/40×4/50×5 mm, custom drilled, equipotential bonding, room lightning grounding.

Anchor: KITOZER by Guangzhou Laian · Grounding Busbar / Copper Bar

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart