The KITOZER HFC-227ea 120L pipe network gas suppression system delivers engineered clean-agent protection for larger hazards such as open-plan data centers, transformer halls, and industrial control rooms. HFC-227ea, commonly known as FM-200, is a colorless, odorless, electrically non-conductive gas that extinguishes fire through heat absorption and chemical flame inhibition without leaving oily residue or particulate. The pipe network configuration uses one or more 120-liter cylinders manifolded together, with routed stainless or galvanized piping and ceiling-mounted nozzles that distribute agent evenly across the protected volume. Because the system is hydraulically calculated, designers can tailor nozzle count, pipe diameter, and cylinder bank size to the actual hazard envelope, rather than accepting the fixed capacity of a pre-engineered cabinet. This scalability makes the pipe network approach the standard choice for medium and large commercial and industrial protection.
Table of Contents
ToggleProduct Overview
Each 120L cylinder is charged with HFC-227ea and pressurized with nitrogen to 4.2 megapascals at 20 degrees Celsius. Cylinder banks of two, three, four, or more units feed a common manifold through flexible high-pressure hoses and check valves. The manifold connects to a distribution network that may serve a single hazard or, through selector valves, multiple hazards from a central cylinder room. A KITOZER gas extinguishing control panel supervises detection loops, releases the master solenoid, and provides pre-discharge alarm, abort timer, and remote status reporting. The arrangement suits projects where cylinder storage must be located outside the protected room for safety or space reasons, and where future expansion may require additional nozzles or zones.
Technical Specifications
Single cylinder capacity is 120 liters, with typical agent fill between 110 and 135 kilograms. Storage pressure is 4.2 megapascals at 20 degrees Celsius. Design concentration is usually seven to eight percent by volume for class A and B hazards, with an extinguishing concentration below six percent. Discharge time is less than ten seconds. Pipework uses galvanized steel or stainless steel with Schedule 40 or 80 ratings, and nozzle orifices are sized per hydraulic calculation. Operating temperature is 0 to 50 degrees Celsius. Solenoid actuator is 24 volts DC. Cylinder test pressure is 25 megapascals. Manifold pressure rating is 12 megapascals. The system supports up to eight selector valves for multi-hazard configurations. Each cylinder is equipped with a pressure gauge, a flexible discharge hose, and a check valve to prevent cross-flow between units.
Application Scenarios
Pipe network HFC-227ea systems are deployed in medium and large data centers, cable transmission rooms, electrical substations, printing press rooms, flammable liquid storage areas, process control rooms, and industrial automation switchgear suites. They are also common in underground rail infrastructure, ship engine rooms, and offshore control cabins where water damage must be avoided. Multi-hazard designs allow one cylinder bank to protect several adjacent rooms sequentially, reducing capital cost versus installing independent cabinets in each room. The system is appropriate where the protected volume exceeds 120 cubic meters and where architectural space allows routed overhead pipework. Typical projects include enterprise data halls, banking computer rooms, hospital imaging suites, and industrial turbine control enclosures.
Advantages
The key benefit is scalability. Cylinder banks can be upsized to match very large hazards without changing the nozzle or control architecture. HFC-227ea is widely accepted by insurers and fire authorities, with decades of installed reference across commercial and industrial buildings. The agent discharges as a gas, so it reaches concealed spaces behind cable trays, under floor raised voids, and inside electrical cabinets that sprinklers cannot wet effectively. It has zero ozone depletion potential and a short atmospheric lifetime, although global warming potential is higher than newer clean agents, so many owners use it as a compliant interim solution. The pipe network also allows remote cylinder storage, which improves personnel safety during maintenance and keeps the cylinder room outside the protected envelope.
Installation and Maintenance
Erect cylinders on a dedicated rack in a ventilated, locked cylinder room, anchored to concrete with seismic restraints. Route piping with slope toward nozzles, support every three meters, and torque flange connections to the specified value. Perform a full network flow test with compressed nitrogen before agent charging, and verify nozzle pressure distribution with the hydraulic calculation report. After commissioning, weigh each cylinder every six months and check pressure gauge monthly; recharge if weight loss exceeds one and a half percent. Inspect pipe supports and nozzle orifices annually, and clean filters if dust accumulation is observed. Recertify cylinders hydrostatically every five years, and replace the solenoid squib per the manufacturer schedule. Keep detection loops free of short circuits, and test the selector valve sequencing annually. Maintain a log of all service activities for insurance and audit purposes.
Price
From $8,600 per cylinder bank including manifold and basic control panel, excluding field piping and nozzles. Contact +86 13922289957 for a turnkey quotation based on your hazard volume.