KITOZER HFC-227ea Gas Suppression System: 90L Cylinder For Server Rooms

KITOZER HFC-227ea clean agent gas suppression system model FG-90 is a total-flooding fire protection package designed for enclosed spaces where water sprinklers would damage critical assets. The system uses heptafluoropropane, a colorless, odorless, electrically non-conductive clean gas that extinguishes fire by heat absorption and chemical inhibition, leaving no residue after discharge. Each 90 liter steel cylinder is charged with 125 kilograms of HFC-227ea at 2.5 megapascal storage pressure, delivered through a network of high-pressure piping and nozzles to achieve design concentration within 10 seconds. The package is ideal for data center server rooms, electrical switchrooms, UPS rooms, control rooms, library archives, and industrial process cabinets.

Product Overview

The KITOZER FG-90 system comprises one or more 90 liter cylinders, a cylinder valve with solenoid actuator, flexible high-pressure hose, check valve, discharge piping, calibrated nozzles, gas detection line, and a gas suppression control panel. The panel monitors two independent detection circuits typically smoke and heat, and releases the gas only after both detectors in a cross-zone pair alarm, with a 30-second pre-discharge delay to allow personnel evacuation. Audible and visual alarms mark the delay, and an abort switch is provided for trained personnel. The panel also interfaces with the building fire alarm, HVAC shutdown, and door holder circuits to seal the protected space during discharge.

Technical Specifications

Clean agent HFC-227ea, C3F7H. Cylinder volume 90 liters. Storage pressure 2.5 megapascal at 20 degrees Celsius. Agent charge per cylinder 125 kilograms. Design concentration 7.0 to 9.0 percent by volume per NFPA 2001. Discharge time 10 seconds to 95 percent of design concentration. Cylinder material manganese steel, hot dipped galvanized externally. Valve pilot operated solenoid, 24 volt DC. Maximum piping length 80 meters equivalent. Nozzle pressure range 0.6 to 1.6 megapascal. Control panel 24 volt DC, two detection circuits, cross-zone logic, 30 second delay, abort switch, RS485 Modbus. Certifications CCCF, ISO 9001, compliant with NFPA 2001 and GB 25972. Warranty 24 months from commissioning, cylinder 10 years hydro test.

Application Scenarios

Typical protected spaces include data center server rooms, electrical switchrooms and transformer bays, UPS and battery rooms, industrial control rooms, process cabinets in manufacturing, library archives and rare book vaults, museum display cases, telecommunications equipment rooms, and flammable liquid handling enclosures. The 90 liter cylinder is sized for rooms of 60 to 90 cubic meters at 8.0 percent concentration. For larger spaces, multiple cylinders manifolded on a common header deliver simultaneous discharge through a single piping network. Engineers select HFC-227ea when the protected space must return to normal operation within minutes after discharge, with no cleanup residue.

Advantages and Features

HFC-227ea leaves no residue, so servers and electrical equipment can be restarted immediately after airing. The gas is electrically non-conductive, safe for live electrical equipment. The 10-second discharge is fast enough to prevent fire spread in energized cabinets. Cross-zone detection logic prevents accidental discharge from a single detector fault. The abort switch gives trained personnel a final chance to cancel a false alarm. The cylinder is accepted by most insurance loss-prevention engineers. KITOZER provides hydraulic calculation of the piping network, nozzle selection, and concentration verification, so the system is delivered code-compliant.

Installation and Maintenance Recommendations

Mount cylinders upright in a dedicated enclosure with ambient temperature between 0 and 50 degrees Celsius. Verify room leakage rate per NFPA 2001, and install pressure vent relief panels if the room is airtight. Conduct monthly visual inspection of cylinder pressure gauge, solenoid voltage, and panel indicators. Perform semi-annual functional test of detection circuits with aerosol smoke tester. Replace cylinders every 10 years and hydrostatically test per local regulation. Recharge agent immediately after any discharge. Keep spare nozzles, fuses, and solenoid coils on site. Train facility staff on the abort switch and manual release procedure. Log every inspection and test in the system logbook.

System Integration

The FG-90 panel interfaces with the building fire alarm system through supervised input and output circuits. On confirmed alarm, the panel shuts down HVAC units serving the protected room, closes motorized fire dampers, unlocks or holds open exit doors, and activates audible and visual alarms both inside and outside the room. A manual release box outside the door allows trained personnel to discharge the gas after the pre-discharge delay, and an abort switch cancels the release if the alarm proves false. KITOZER coordinates the zoning diagram, detection circuit layout, and release matrix with the fire alarm integrator, so the gas system and the sprinkler system do not conflict. The panel also sends a dry contact to the BMS indicating pre-discharge, discharge, fault, and supervisory conditions for remote monitoring by the facility operations center.

Price

From 3,600 US dollars per 90 liter charged cylinder including valve, solenoid, flexible hose, and mounting bracket. Complete system with control panel, piping, and nozzles quoted per room hydraulic calculation. Contact KITOZER for sizing and lead time.