KITOZER
KITOZER

KITOZER HFC-227ea Seven Fluoropropane Fire Suppression 4.2 MPa

Product Overview

The KITOZER HFC-227ea (HFC-227ea, FM-200) fire suppression system is a 4.2 MPa clean agent total-flooding solution. HFC-227ea is a colorless, odorless, electrically non-conductive gas that suppresses fire by chemical inhibition of the combustion reaction. Discharge occurs within 10 seconds, and design concentrations of 7 to 9 percent by volume are effective on Class A, B, and C fires. Because HFC-227ea is stored as a liquid, cylinder quantities are much smaller than inert gas systems, making it ideal for projects with limited cylinder room space. It is the most widely adopted clean agent in data centers, switch rooms, and control rooms globally. The agent has a proven track record of over 30 years in fire protection. KITOZER provides as-built drawings after installation. The system is also compatible with addressable fire alarm panels for integration. KITOZER also provides operator training sessions for the customer facilities team. The training covers release sequence, abort procedure, and routine inspection. KITOZER also provides a 5-year cylinder warranty on the system. The system is also backed by a 24-hour emergency support hotline. KITOZER can also provide a VESDA aspirating detector integration package for earliest warning.

HFC-227ea is available in two storage pressure options: 2.5 MPa (25 bar) for shorter pipe runs and 4.2 MPa (42 bar) for longer networks where higher pressure compensates for pipe friction. KITOZER provides both variants and selects the appropriate pressure based on the hydraulic calculation. The 4.2 MPa model uses heavier Schedule 40 high-pressure piping and brass nozzles rated for 100 bar service. KITOZER also supplies pre-assembled cabinet units that combine the cylinder, valve, actuator, and control panel in a single wall-mounted cabinet for small rooms with no dedicated cylinder space.

Technical Specifications

Agent: HFC-227ea (heptafluoropropane), CAS 431-89-0. Storage pressure: 2.5 MPa (25 bar) at 20 degrees Celsius, or 4.2 MPa (42 bar) high-pressure model. Cylinder: 40L, 70L, 90L, 120L steel. Fill density: 1125 kg per cubic meter max (low pressure), 950 kg per cubic meter (high pressure). Design concentration: 7 to 9 percent. Discharge time: less than 10 seconds. Hold time: 10 minutes. Piping: Schedule 40 black steel, threaded. Nozzles: brass, adjustable. Actuator: 24V DC electric + manual. ODP: 0. GWP: 3220 (100-year). Atmospheric lifetime: 36 years. Certifications: NFPA 2001, ISO 14520, GB 25973. KITOZER brand, 5 year cylinder warranty. The system also supports BMS integration for remote monitoring.

Applications

HFC-227ea is the standard for data center server rooms, UPS rooms, electrical switchgear rooms, battery rooms, telephone exchanges, control rooms, process automation panels, museums, and archive vaults. It is especially suitable when cylinder room space is constrained, because a single 90L cylinder protects 100 cubic meters of room. KITOZER supplies both pipe-network systems (multi-room, selector valves) and cabinet-unit systems (pre-assembled 40L units for single rooms). The cabinet units are popular in small telecom closets and remote bank branches where a full pipe network would be overkill. They arrive pre-charged and ready to install. The cabinet unit includes the cylinder, valve, actuator, and a small control panel in one wall-mounted enclosure.

Key Advantages

First, fast 10-second discharge beats fire spread. Second, compact cylinders require less floor space. Third, effective on Class A, B, C fires. Fourth, non-conductive and residue-free. Fifth, proven track record over 30 years. Sixth, global approvals. Seventh, lower installed cost than inert gas for small rooms. Eighth, both 2.5 MPa and 4.2 MPa options match pipe length. Ninth, the agent is electrically non-conductive and safe on energized electrical equipment. The system also supports BMS integration for remote cylinder pressure and alarm monitoring. KITOZER also provides a web-based dashboard for remote monitoring.

Installation and Maintenance

Cylinders are mounted on brackets, piped with Schedule 40 threaded steel, and nozzles installed per hydraulic calculation. A small pressure vent is required. Commissioning includes actuator test, detector walk test, and abort switch test. Maintenance: weigh cylinders every 6 months, refill if loss exceeds 1.5 percent, test detectors annually, hydrotest cylinders every 12 years. KITOZER supplies HFC-227ea refill, valves, and nozzles globally.

Warranty and Global Support

KITOZER supplies HFC-227ea refill, valves, and nozzles globally, backed by a 5-year cylinder warranty. Spare actuators, pressure switches, and detector bases are held in regional stock. KITOZER also offers long-term service contracts covering semi-annual cylinder weighing, annual detector testing, and 12-year hydrostatic testing. Pre-assembled cabinet units are available for small rooms. The system is also backed by a 24-hour emergency support hotline. KITOZER also provides a 5-year cylinder warranty on the system. Spare parts are shipped from regional stock worldwide. KITOZER provides global support. Spare parts are shipped from regional stock. KITOZER also provides a 24-hour emergency support hotline.

Price

From $6,800 per small room (one 90L cylinder, piping, nozzles, control panel). Contact +86 13922289957 for HFC-227ea project design.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com