KITOZER High Pressure Water Mist Fire Suppression System

The KITOZER high pressure water mist fire suppression system uses demineralized water pressurized to 10 to 14 megapascals and discharged through special nozzles that produce fine droplets under 1000 micrometers. The large surface area of these droplets absorbs heat rapidly, displaces oxygen near the flame, and blocks radiant heat, delivering extinguishing performance comparable to gas systems while using only a fraction of the water volume of sprinklers. This makes water mist ideal for spaces where both fire suppression and minimal water damage are required, such as heritage buildings and sensitive electronics rooms.

Product Overview

The system comprises a high pressure pump unit, a water storage tank, a nitrogen cylinder for pump activation or for pre-engineered sealed systems, a control panel, stainless steel piping, and mist nozzles. Detection is via smoke and heat detectors wired to the panel. On alarm, the panel starts the pump or releases nitrogen, pressurizes the water network, and opens zone valves. Nozzles discharge a fine mist that floods the protected volume within seconds. The pump unit has duty and standby pumps for redundancy.

Technical Specifications

Working pressure is 10 to 14 megapascals. Droplet size Dv0.99 is below 1000 micrometers. Water flow per nozzle is 5 to 25 liters per minute. Pipework is stainless steel 316 rated for 16 megapascals. Pump units provide 1 to 30 kilowatts. Operating temperature is 5 to 50 degrees Celsius. The system supports single-zone or multi-zone configurations with selector valves. The water tank is sized for the design discharge duration plus reserve.

Application Scenarios

High pressure water mist is specified for marine engine rooms, offshore modules, data center rooms, transformer and switchgear rooms, museum galleries, archive stacks, cooking exhaust hoods, and industrial process areas. It is also used in heritage buildings and historic structures where large quantities of water would cause unacceptable damage. The system is effective on class A, B, and electrical hazards and is suitable for normally occupied spaces. It is also used in subway stations and tunnel environments.

Advantages

Water mist uses up to 90 percent less water than conventional sprinklers, reducing flood damage. The fine mist does not harm sensitive electronics or paper documents. It suppresses radiant heat, protecting adjacent equipment and structures. There are no hazardous agents, no environmental compliance issues, and no refill cost beyond demineralized water. The system is effective on deep-seated class A fires and on flammable liquid spills. It also controls smoke and reduces temperature in the protected space.

Installation and Maintenance

Install the pump unit and water tank in a dedicated room with drainage and water supply. Route stainless steel pipework with orbital welds or compression fittings, and pressure test at 1.5 times working pressure. Flush and clean pipework before nozzle installation. Commission with a full flow test and verify nozzle coverage. After installation, inspect nozzles monthly for dust or damage. Test pump operation weekly. Replace filters quarterly. Drain and winterize if the room may freeze. Have the system serviced annually by a qualified technician.

Engineering Notes

Use demineralized or softened water to prevent nozzle blockage and mineral scale. Size the water tank for the longest design discharge duration plus 30 percent reserve. Provide a duty and standby pump with automatic switchover. Verify that pipework supports can withstand the high-pressure transient. Coordinate nozzle layout with HVAC ductwork and lighting to avoid obstruction. Keep a nozzle spare kit on site with all sizes used in the project.

Code and Compliance

High pressure water mist systems are designed under local water mist standards and approved by the fire authority. Submit the hydraulic calculation, nozzle schedule, and water storage volume for review. The pump unit must have a duty and standby pump with automatic switchover. Annual testing includes a full flow test and nozzle inspection. Keep water quality records and filter change logs. Replacement nozzles must match the original flow rating.

Detailed Application Examples

A marine engine room uses high pressure water mist with two duty pumps and a 10 cubic meter water tank. Stainless steel pipework runs along the deckhead with nozzles over each engine. The system is tested annually with a full discharge, and filters are changed quarterly. Demineralized water is supplied by a dedicated treatment unit.

Price

From $12,500 for a single-zone pump package. Related accessories include spare pump heads, filter cartridges, pressure gauges, zone valves, nozzle kits, and pressure tanks. KITOZER supplies compatible duty standby pump controllers and water treatment cartridges. The pump unit with 10 nozzles. The pump unit carries a two-year warranty, and KITOZER provides hydraulic design support, nozzle layout, and commissioning assistance. Spare pumps, filters, and nozzle kits are available. Remote monitoring integration is offered through optional Modbus or Ethernet cards. Contact +86 13922289957 for multi-zone project pricing.