KITOZER
KITOZER

KITOZER High Voltage Switchgear System Solution

Table of Contents

1. System Overview

The KITOZER high voltage switchgear system is core medium-voltage power distribution equipment covering 3.6kV ~ 40.5kV. It integrates circuit breakers, relay protection, measurement & control, communication and condition monitoring functions. It is applied to power transmission, generation and distribution for power switching, control, protection and metering, ensuring safe and stable operation of power grids and equipment.

Adopting a metal-clad enclosed structure, the system strictly implements the “Five Prevention” interlock functions:

  1. Prevent accidental closing/opening of circuit breakers
  2. Prevent opening/closing disconnectors under load
  3. Prevent earthing wire connection to live equipment
  4. Prevent closing circuit breakers with earthing wires connected
  5. Prevent access to live compartments

It features high reliability, safety and maintainability. Customizable design is available according to load levels and environmental conditions for conventional industry, new energy (photovoltaic/wind power/energy storage), data centers, rail transit, municipal construction and other scenarios.

image

KITOZER High Voltage Switchgear

2. System Composition

The system consists of four major parts: primary main circuit, secondary control & protection circuit, cabinet structure and intelligent monitoring modules.

Primary Main Circuit (High Voltage Section)

Vacuum circuit breaker (core switching device), disconnector/earthing switch, current transformer (CT), voltage transformer (PT), lightning arrester, main busbar, branch busbar, cable terminal, contact system, insulating components (epoxy resin / eco-friendly gas).

Secondary Control & Protection Circuit (Low Voltage Section)

Microcomputer protection device, measurement & control unit, intelligent control device, power quality monitoring meter, temperature & humidity controller, heating & dehumidifier, indicator lights/buttons, terminal block, communication interface (RS485 / Ethernet).

Cabinet Structure

Cold-rolled steel / aluminized zinc steel cabinet divided into circuit breaker compartment, busbar compartment, cable compartment, relay & instrument compartment and top small busbar compartment; equipped with pressure relief windows, ventilation heat dissipation holes, earthing devices, mechanical interlocks, door locks & hinges.

Intelligent Monitoring Modules

Wireless temperature measuring sensors (contacts / busbars), partial discharge monitoring unit (ultrasonic / UHF), arc flash protection sensor, SF6 gas monitor (eco-friendly type), optional video surveillance.

3. System Classification

3.1 Classification by Circuit Breaker Installation Type

  • Draw-out type (handcart type, KYN series): Circuit breakers installed on extractable handcarts with strong interchangeability, high power supply reliability and convenient maintenance. Main models: KYN28A-12 (12kV), KYN61-40.5 (40.5kV).
  • Fixed type (XGN/GG series): Fixed-mounted circuit breakers with simple and economical structure, suitable for small power distribution systems. Main models: XGN2-10, GG-1A.
  • Ring main unit (HXGN series): Compact design fitted with load switches/fuses for ring network power supply and terminal power distribution. Main model: HXGN12-12.
image

High Voltage Switchgear General Layout Drawing

3.2 Classification by Voltage Level

  • Medium voltage 12kV: Mainstream power distribution grade covering industry, construction and new energy power stations.
  • Medium voltage 24kV: High-density load scenarios (data centers, large factories).
  • Medium voltage 40.5kV: Regional power distribution, small & medium power plants and new energy booster stations.

3.3 Classification by Insulation Medium

  • Air Insulated Switchgear (AIS): Conventional cabinets with air as insulation medium, low cost for standard environments.
  • Solid Insulated Switchgear (SIS): Busbars and switching components encapsulated with epoxy resin, isolated from moisture/dust with service life ≥30 years, ideal for high-pollution/high-humidity scenarios.
  • Eco-friendly Gas Insulated Switchgear (GIS): C4F7N/CF3I low GWP gas replaces SF6 with equivalent insulation and arc extinction performance, greenhouse effect less than 1% of SF6, the preferred option for green low-carbon scenarios.

3.4 Classification by Functional Purpose

  • Incoming cabinet: Power supply access equipped with main circuit breakers and differential protection.
  • Outgoing cabinet: Load distribution fitted with feeder circuit breakers, overcurrent & instantaneous protection.
  • Bus coupler cabinet: Busbar connection with Busbar Transfer (BZT) function, charging protection and anti-false closing logic.
  • PT cabinet: Voltage monitoring, metering and overvoltage protection equipped with voltage transformers and lightning arresters.
  • Metering cabinet: Electric energy metering with high-precision CT/PT and energy meters.
  • Capacitor cabinet: Reactive power compensation to improve power factor.
  • Station Transformer Cabinet: Station power conversion fitted with dry-type transformers.

4. System Schematic Diagrams

4.1 Primary System Schematic (12kV Single Busbar Sectionalized)

4.2 Secondary Control & Protection Schematic (Incoming Cabinet Example)

  1. Three-phase power supply → CT → Microcomputer protection device → Circuit breaker trip coil
  2. PT → Protection device → Voltage monitoring / Overvoltage protection
  3. Intelligent control device → Closing & opening control, status display, temperature & humidity monitoring
  4. Communication interface → SCADA/EMS system for remote monitoring and data uploading
image

On-site Installation of High Voltage Switchgear

5. Full System Configuration List (Basic / Standard / High-End, Brand: KITOZER)

5.1 Low-Grade Configuration List (Basic Type, 12kV/630A/20kA)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1High Voltage Switchgear (Incoming Cabinet)KYN28A-12-JRated voltage:12kV; Rated current:630A; Short-time withstand current:20kA/4s; Peak withstand current:50kA; Protection class:IP4X; Dimension:800×1500×2200mm1SetKITOZERAir insulated, cold-rolled steel plate
2High Voltage Switchgear (Outgoing Cabinet)KYN28A-12-CRated voltage:12kV; Rated current:630A; Short-time withstand current:20kA/4s; Peak withstand current:50kA; Protection class:IP4X; Dimension:800×1500×2200mm2SetKITOZERAir insulated, cold-rolled steel plate
3High Voltage Switchgear (PT Cabinet)KYN28A-12-PTRated voltage:12kV; PT ratio:10/0.1kV; Protection class:IP4X; Dimension:800×1500×2200mm1SetKITOZERAir insulated, cold-rolled steel plate
4Vacuum Circuit BreakerVS1-12/630-20Rated voltage:12kV; Rated current:630A; Short-circuit breaking current:20kA; Mechanical life:10,000 times, handcart type3SetKITOZERFor incoming/outgoing cabinets
5Current TransformerLZZBJ9-10 600/5ARated voltage:10kV; Ratio:600/5A; Accuracy class:0.5/10P10; Rated burden:10VA6SetKITOZER2 sets each for incoming/outgoing cabinets
6Voltage TransformerJDZJ-10 10/0.1/0.1kVRated voltage:10kV; Ratio:10/0.1/0.1kV; Accuracy class:0.5/3P; Rated burden:30VA3SetKITOZERDedicated for PT cabinet
7Zinc Oxide Lightning ArresterHY5WZ-17/45Rated voltage:17kV; Continuous operating voltage:13.6kV; Residual voltage:45kV; Nominal discharge current:5kA3SetKITOZERFor PT/incoming cabinets
8Microcomputer Protection DeviceKZ-100Protection functions: overcurrent, instantaneous trip, zero-sequence, overvoltage, undervoltage; Communication:RS485; Accuracy:±0.5%3SetKITOZERFor incoming/outgoing/PT cabinets
9Intelligent Control DeviceKZ-C10Closing/opening control, status display, temperature & humidity monitoring, heating & dehumidification; Communication:RS4854SetKITOZER1 set per cabinet
10Temperature & Humidity ControllerKZ-WSTemperature range:-20℃~+60℃; Humidity range:0~100% RH; Heating/dehumidification output4SetKITOZER1 set per cabinet
11Heating & DehumidifierKZ-JRPower:100W; Voltage:AC220V, anti-condensation4SetKITOZER1 set per cabinet
12Main BusbarTMY-60×6Material:copper; Size:60×6mm; Rated current:1250A10MeterKITOZERTin-plated pure copper
13Earthing SwitchJN15-12Rated voltage:12kV; Rated short-time withstand current:20kA/4s; Mechanical life:2,000 times4SetKITOZER1 set per cabinet
14Mechanical Interlock DeviceKZ-L10“Five Prevention” interlock, dual mechanical & electrical locking4SetKITOZER1 set per cabinet

5.2 Medium-Grade Configuration List (Standard Type, 12kV/1250A/31.5kA, Intelligent Upgrade)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1High Voltage Switchgear (Incoming Cabinet)KYN28A-12-JSRated voltage:12kV; Rated current:1250A; Short-time withstand current:31.5kA/4s; Peak withstand current:80kA; Protection class:IP5X; Dimension:1000×1800×2400mm; Aluminized zinc steel plate1SetKITOZERAir insulated, intelligent monitoring
2High Voltage Switchgear (Outgoing Cabinet)KYN28A-12-CSRated voltage:12kV; Rated current:1250A; Short-time withstand current:31.5kA/4s; Peak withstand current:80kA; Protection class:IP5X; Dimension:1000×1800×2400mm; Aluminized zinc steel plate3SetKITOZERAir insulated, intelligent monitoring
3High Voltage Switchgear (Bus Coupler Cabinet)KYN28A-12-MLRated voltage:12kV; Rated current:1250A; Short-time withstand current:31.5kA/4s; Peak withstand current:80kA; Protection class:IP5X; Dimension:1000×1800×2400mm; Aluminized zinc steel plate1SetKITOZERAir insulated, intelligent monitoring
4High Voltage Switchgear (PT Cabinet)KYN28A-12-PTSRated voltage:12kV; PT ratio:10/0.1kV; Protection class:IP5X; Dimension:800×1800×2400mm; Aluminized zinc steel plate1SetKITOZERAir insulated, intelligent monitoring
5Vacuum Circuit BreakerVS1-12/1250-31.5Rated voltage:12kV; Rated current:1250A; Short-circuit breaking current:31.5kA; Mechanical life:15,000 times, handcart electric operation5SetKITOZERFor incoming/outgoing/bus coupler cabinets
6Current TransformerLZZBJ9-10 1250/5ARated voltage:10kV; Ratio:1250/5A; Accuracy class:0.2S/10P20; Rated burden:15VA10SetKITOZER2 sets each for incoming/outgoing/bus coupler cabinets
7Voltage TransformerJDZJ-10 10/0.1/0.1kVRated voltage:10kV; Ratio:10/0.1/0.1kV; Accuracy class:0.2S/3P; Rated burden:50VA3SetKITOZERDedicated for PT cabinet
8Zinc Oxide Lightning ArresterHY5WZ-17/45Rated voltage:17kV; Continuous operating voltage:13.6kV; Residual voltage:45kV; Nominal discharge current:10kA3SetKITOZERFor PT/incoming cabinets
9Microcomputer Protection DeviceKZ-200Protection functions: differential, overcurrent, instantaneous trip, zero-sequence, overvoltage, undervoltage, breaker failure; Communication:Ethernet/RS485; Accuracy:±0.2%5SetKITOZERFor incoming/outgoing/bus coupler/PT cabinets
10Intelligent Control DeviceKZ-C20Closing/opening control, status display, temperature & humidity monitoring, heating & dehumidification, wireless temperature measurement reception; Communication:Ethernet/RS4856SetKITOZER1 set per cabinet
11Wireless Temperature Measuring SensorKZ-TWMeasuring range:-50℃~+125℃; Accuracy:±0.5℃; Transmission distance:≥50m; Service life of battery:≥5 years24PieceKITOZERFor circuit breaker contacts / busbar lap joints
12Partial Discharge Monitoring UnitKZ-JFMonitoring mode:Ultrasonic + UHF; Sensitivity:≤10pC; Communication:Ethernet; Adjustable early warning & alarm thresholds6SetKITOZER1 set per cabinet
13Arc Flash Protection SensorKZ-HGResponse time:≤1ms; Monitoring angle:180°; Communication:Ethernet; Fault location6PieceKITOZERFor circuit breaker / busbar compartments
14Power Quality Monitoring MeterKZ-PQMonitored parameters:voltage/current/frequency/power/harmonics; Accuracy:0.2S class; Communication:Ethernet6SetKITOZER1 set per cabinet
15Temperature & Humidity ControllerKZ-WSTemperature range:-20℃~+60℃; Humidity range:0~100% RH; Heating/dehumidification output; Communication:RS4856SetKITOZER1 set per cabinet
16Heating & DehumidifierKZ-JRPower:150W; Voltage:AC220V, anti-condensation with temperature control6SetKITOZER1 set per cabinet
17Main BusbarTMY-80×8Material:copper; Size:80×8mm; Rated current:2000A15MeterKITOZERTin-plated pure copper with insulation coating
18Earthing SwitchJN15-12Rated voltage:12kV; Rated short-time withstand current:31.5kA/4s; Mechanical life:3,000 times, electric operation6SetKITOZER1 set per cabinet
19Mechanical Interlock DeviceKZ-L20“Five Prevention” interlock, dual mechanical & electrical locking with electric interlock6SetKITOZER1 set per cabinet
20Intelligent Communication GatewayKZ-GWProtocol conversion:IEC61850/Modbus-RTU/Profinet; Interfaces:4×Ethernet / 2×RS485; Data encryption1SetKITOZERSystem data aggregation

5.3 High-Grade Configuration List (Premium Type, 40.5kV/3150A/40kA, Eco-Friendly Intelligent)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1High Voltage Switchgear (Incoming Cabinet)KYN61-40.5-JGRated voltage:40.5kV; Rated current:3150A; Short-time withstand current:40kA/4s; Peak withstand current:100kA; Protection class:IP55; Dimension:1200×2000×2600mm; Eco-friendly gas insulated (C4F7N)1SetKITOZEREco-friendly gas insulated, intelligent monitoring
2High Voltage Switchgear (Outgoing Cabinet)KYN61-40.5-CGRated voltage:40.5kV; Rated current:3150A; Short-time withstand current:40kA/4s; Peak withstand current:100kA; Protection class:IP55; Dimension:1200×2000×2600mm; Eco-friendly gas insulated (C4F7N)4SetKITOZEREco-friendly gas insulated, intelligent monitoring
3High Voltage Switchgear (Bus Coupler Cabinet)KYN61-40.5-MLGRated voltage:40.5kV; Rated current:3150A; Short-time withstand current:40kA/4s; Peak withstand current:100kA; Protection class:IP55; Dimension:1200×2000×2600mm; Eco-friendly gas insulated (C4F7N)1SetKITOZEREco-friendly gas insulated, intelligent monitoring
4High Voltage Switchgear (PT Cabinet)KYN61-40.5-PTGRated voltage:40.5kV; PT ratio:35/0.1kV; Protection class:IP55; Dimension:1000×2000×2600mm; Eco-friendly gas insulated (C4F7N)1SetKITOZEREco-friendly gas insulated, intelligent monitoring
5Vacuum Circuit BreakerZN85-40.5/3150-40Rated voltage:40.5kV; Rated current:3150A; Short-circuit breaking current:40kA; Mechanical life:20,000 times, handcart electric/spring operation6SetKITOZERFor incoming/outgoing/bus coupler cabinets
6Current TransformerLZZBJ9-35 3000/5ARated voltage:35kV; Ratio:3000/5A; Accuracy class:0.2S/10P20; Rated burden:20VA; Insulation level:40.5kV12SetKITOZER2 sets each for incoming/outgoing/bus coupler cabinets
7Voltage TransformerJDZJ-35 35/0.1/0.1kVRated voltage:35kV; Ratio:35/0.1/0.1kV; Accuracy class:0.2S/3P; Rated burden:50VA; Insulation level:40.5kV3SetKITOZERDedicated for PT cabinet
8Zinc Oxide Lightning ArresterHY5WZ-51/134Rated voltage:51kV; Continuous operating voltage:40.8kV; Residual voltage:134kV; Nominal discharge current:20kA; Insulation level:40.5kV3SetKITOZERFor PT/incoming cabinets
9Microcomputer Protection DeviceKZ-300Protection functions: differential, overcurrent, instantaneous trip, zero-sequence, overvoltage, undervoltage, breaker failure, reclosing; Communication:IEC61850/Ethernet; Accuracy:±0.1%; Dual power redundancy6SetKITOZERFor incoming/outgoing/bus coupler/PT cabinets
10Intelligent Control DeviceKZ-C30Closing/opening control, status display, temperature & humidity monitoring, heating & dehumidification, wireless temperature measurement reception, partial discharge data display; Communication:IEC61850/Ethernet, touch screen7SetKITOZER1 set per cabinet
11Wireless Temperature Measuring SensorKZ-TW-GMeasuring range:-50℃~+150℃; Accuracy:±0.3℃; Transmission distance:≥100m; Service life of battery:≥8 years, high temperature resistance28PieceKITOZERFor circuit breaker contacts / busbar lap joints / cable terminals
12Partial Discharge Monitoring UnitKZ-JF-GMonitoring mode:Ultrasonic + UHF + High-frequency current; Sensitivity:≤5pC; Communication:IEC61850/Ethernet; AI algorithm early warning; Positioning accuracy:≤30cm7SetKITOZER1 set per cabinet
13Arc Flash Protection SensorKZ-HG-GResponse time:≤0.5ms; Monitoring angle:360°; Communication:IEC61850/Ethernet; Fault location + partition tripping7PieceKITOZERFor circuit breaker / busbar / cable compartments
14SF6 / Eco-Friendly Gas MonitorKZ-QTMonitored gas:C4F7N/SF6; Concentration range:0~100%; Accuracy:±1%; Leakage alarm; Communication:Ethernet7SetKITOZER1 set per cabinet
15Power Quality Monitoring MeterKZ-PQ-GMonitored parameters:voltage/current/frequency/power/harmonics/transient/flicker; Accuracy:0.1S class; Communication:IEC61850/Ethernet, waveform recording function7SetKITOZER1 set per cabinet
16Temperature & Humidity ControllerKZ-WS-GTemperature range:-40℃~+70℃; Humidity range:0~100% RH; Heating/dehumidification output; Communication:IEC61850/Ethernet, dual-circuit control7SetKITOZER1 set per cabinet
17Heating & DehumidifierKZ-JR-GPower:200W; Voltage:AC220V/DC220V, anti-condensation with temperature/humidity control, corrosion resistance7SetKITOZER1 set per cabinet
18Main BusbarTMY-100×10Material:copper; Size:100×10mm; Rated current:4000A; Silver-plated pure copper with insulation coating and heat shrink protection20MeterKITOZERDedicated for eco-friendly gas insulated cabinets
19Earthing SwitchJN15-40.5Rated voltage:40.5kV; Rated short-time withstand current:40kA/4s; Mechanical life:5,000 times, electric/spring operation with position monitoring7SetKITOZER1 set per cabinet
20Mechanical Interlock DeviceKZ-L30“Five Prevention” interlock, triple mechanical + electrical + intelligent locking with electric interlock and status monitoring7SetKITOZER1 set per cabinet
21Intelligent Communication GatewayKZ-GW-GProtocol conversion:IEC61850/Modbus-RTU/Profinet/DNP3; Interfaces:8×Ethernet / 4×RS485 / 2×Optical fiber; Data encryption + redundant backup, edge computing2SetKITOZERSystem data aggregation + redundancy
22Intelligent Monitoring PlatformKZ-MPFunctions: real-time monitoring, fault early warning, data analysis, report generation, remote operation & maintenance, video linkage; Deployment: local / cloud, multi-level user authority management1SetKITOZERSystem management center

6. Full Product Technical Parameters

image

Finished High Voltage Switchgear Workshop

6.1 Cabinet Parameters of High Voltage Switchgear

  • Rated voltage: 3.6kV, 7.2kV, 12kV, 24kV, 40.5kV
  • Rated current: 630A, 1000A, 1250A, 1600A, 2000A, 2500A, 3150A, 4000A
  • Rated short-time withstand current (Icw): 20kA, 25kA, 31.5kA, 40kA (4s)
  • Rated peak withstand current (Ipk): 50kA, 63kA, 80kA, 100kA
  • Protection class: IP4X (Basic), IP5X (Standard), IP55 (Premium)
  • Cabinet material: Cold-rolled steel (Basic), Aluminized zinc steel (Standard), Stainless steel (Premium)
  • Dimension (Width × Depth × Height, mm): 12kV: 800/1000×1500/1800×2200/2400 40.5kV: 1200×2000×2600
  • Insulation level: 12kV: Power frequency withstand voltage 42kV/1min, Lightning impulse withstand voltage 75kV (peak) 40.5kV: Power frequency withstand voltage 95kV/1min, Lightning impulse withstand voltage 185kV (peak)
  • Environmental conditions: Temperature: -15℃~+40℃ (Basic), -40℃~+70℃ (Premium) Humidity: Daily average ≤95% RH, Monthly average ≤90% RH Altitude: ≤1000m (Standard), reinforced insulation required for altitude>1000m Pollution class: Class III (Standard), Class IV (High pollution)

6.2 Vacuum Circuit Breaker Parameters (VS1/ZN85 Series)

  • Rated voltage: 12kV (VS1), 40.5kV (ZN85)
  • Rated current: 630A ~ 3150A
  • Rated short-circuit breaking current: 20kA, 25kA, 31.5kA, 40kA
  • Rated short-circuit making current: 2.5 times breaking current (peak value)
  • Mechanical life: 10,000 times (Basic), 15,000 times (Standard), 20,000 times (Premium)
  • Operating mechanism: Electromagnetic (Basic), Spring (Standard), Electric/Spring (Premium)
  • Opening & closing time: Opening ≤0.06s, Closing ≤0.1s

6.3 Transformer Parameters (CT/PT)

image

Primary Circuit Schematic Drawing

Current Transformer (LZZBJ9 Series)

  • Rated voltage: 10kV, 35kV
  • Ratio: 200/5A ~ 3000/5A
  • Accuracy class: 0.5/10P10 (Basic), 0.2S/10P20 (Standard/Premium)
  • Rated burden: 10VA ~ 20VA

Voltage Transformer (JDZJ Series)

  • Rated voltage: 10kV, 35kV
  • Ratio: 10/0.1/0.1kV, 35/0.1/0.1kV
  • Accuracy class: 0.5/3P (Basic), 0.2S/3P (Standard/Premium)
  • Rated burden: 30VA ~ 50VA

6.4 Microcomputer Protection Device Parameters (KZ-100/200/300)

Protection Functions

  • Basic: Overcurrent, Instantaneous trip, Zero-sequence, Overvoltage, Undervoltage
  • Standard: Plus differential protection, breaker failure protection, reclosing
  • Premium: Plus transient protection, harmonic protection, frequency protection

Measurement Accuracy

±0.5% (Basic), ±0.2% (Standard), ±0.1% (Premium)

Communication Interfaces

RS485 (Basic), Ethernet + RS485 (Standard), IEC61850 + Ethernet (Premium)

Operating Power Supply

AC220V/DC220V, dual power redundancy (Premium)

6.5 Intelligent Monitoring Module Parameters

Wireless Temperature Measuring Sensor (KZ-TW)

  • Measuring range: -50℃~+125℃ (Basic), -50℃~+150℃ (Premium)
  • Accuracy: ±0.5℃ (Basic), ±0.3℃ (Premium)
  • Transmission distance: ≥50m (Basic), ≥100m (Premium)
  • Battery service life: ≥5 years (Basic), ≥8 years (Premium)

Partial Discharge Monitoring Unit (KZ-JF)

  • Monitoring mode: Ultrasonic + UHF (Standard), Ultrasonic + UHF + High-frequency current (Premium)
  • Sensitivity: ≤10pC (Standard), ≤5pC (Premium)
  • Communication: Ethernet (Standard), IEC61850 + Ethernet (Premium)

Arc Flash Protection Sensor (KZ-HG)

  • Response time: ≤1ms (Standard), ≤0.5ms (Premium)
  • Monitoring angle: 180° (Standard), 360° (Premium)
  • Communication: Ethernet (Standard), IEC61850 + Ethernet (Premium)

7. Full Product Application Scope

image

Internal Busbar Layout of Switchgear

7.1 Industrial Sector

  • Manufacturing: Automobile manufacturing, iron & steel metallurgy, chemical industry, textile, food processing factory power distribution workshops, production line power supply, motor control
  • Mining & Energy: Coal mines, metal mines, photovoltaic power stations, wind farms, energy storage power stations, hydropower booster stations & distribution rooms
  • Data Centers: IDC computer rooms, cloud computing center high voltage power distribution, UPS front-end power supply, backup power switching

7.2 Construction & Municipal Engineering

  • Commercial Buildings: Large shopping malls, office buildings, hotels, exhibition centers high voltage power distribution rooms, emergency power supply systems
  • Residential & Public Facilities: High-rise residential quarters, hospitals, schools, stadiums, airports, railway stations, subway power distribution systems
  • Municipal Projects: Urban power grid renovation, substation construction, street lighting power distribution, water supply & drainage pump station power supply

7.3 New Energy Sector

  • Photovoltaic Power Stations: Centralized / distributed photovoltaic booster stations, 12kV/35kV combiner boxes, inverter front-end power distribution
  • Wind Farms: Onshore / offshore wind farm 35kV booster stations, wind turbine box transformer high-voltage side protection, collector line power distribution
  • Energy Storage Power Stations: Lithium battery energy storage system 12kV/35kV high voltage power distribution, PCS front-end protection, grid-connected interface equipment

7.4 Transportation Sector

  • Rail Transit: Subway, light rail, high-speed railway traction substations, step-down substations, signal system power supply
  • Ports & Terminals: Container terminals, bulk cargo terminals high voltage power distribution, crane power supply, port lighting systems

8. Full Product Advantages

image

Intelligent Central Monitoring Platform

8.1 Core Functional Features

  1. High Safety: Fully enclosed metal structure with “Five Prevention” interlock design, arc isolation and pressure relief devices to prevent misoperation and arc fault spread
  2. High Reliability: Self-developed high-quality core components, modular design, anti-vibration & anti-interference performance suitable for harsh environments; intelligent monitoring early warning to eliminate hidden dangers in advance and reduce failure rate
  3. High Intelligence: Integrated microcomputer protection, measurement & control, communication and condition monitoring (temperature measurement / partial discharge / arc flash), supporting remote monitoring, operation & maintenance and fault diagnosis, applicable to smart power grids and unattended scenarios
  4. Eco-Friendly & Energy Saving: Premium models adopt eco-friendly gas insulation to replace SF6, low-loss design reduces energy consumption and carbon emissions; oil-free equipment avoids oil pollution
  5. Flexible Customization: Custom design & production according to user voltage level, current capacity, short-circuit parameters, functional requirements (intelligent / eco-friendly / explosion-proof) and environmental conditions (high temperature / low temperature / humid / polluted)

8.2 Customization & OEM/ODM Capacity

  1. Custom Design: Support non-standard dimensions, special functions (explosion-proof / anti-corrosion / high temperature resistance), special voltage/current parameter customization; adapt to old equipment renovation and special scenarios (offshore / plateau / high pollution)
  2. OEM/ODM Processing: Provide OEM labeling, drawing processing and complete set assembly services; produce strictly in accordance with customer standards and brand requirements to guarantee consistent quality; full-process confidentiality to protect customer intellectual property and commercial secrets
  3. Fast Delivery: Standardized modules + flexible production lines, mainstream 12kV models in stock for spot supply; customized models shorten production cycle to respond quickly to urgent customer demands

8.3 Technical & Quality Advantages

  1. Self-Developed Core Technology: Master core technologies of high voltage switches, intelligent protection and condition monitoring with over 50 patents; continuous technical iteration, product performance reaches international advanced level
  2. Strict Quality Control: Raw material incoming inspection, full-process production inspection, factory type test (insulation / voltage withstand / short-circuit / temperature rise); certified by ISO9001 quality system, national 3C certification and type test certification, complying with national standards GB/T 3906, DL/T 404 etc.
  3. Full-Range Parameter Coverage: Voltage 3.6kV~40.5kV, current 630A~4000A, short-circuit current 20kA~40kA, covering all medium-voltage power distribution scenarios; three grades (Basic/Standard/Premium) matching different budgets and functional demands

9. Product Bid Winning Parameters (Marked with *)

image

Workshop Stock of High Voltage Switchgear

9.1 Cabinet Bid Winning Parameters

    • Rated voltage: 3.6kV ~ 40.5kV (selected on demand)
    • Rated current: 630A ~ 4000A (selected on demand)
    • Rated short-time withstand current: ≥20kA (4s)
    • Protection class: ≥IP4X (Basic), ≥IP5X (Standard), ≥IP55 (Premium)
    • Insulation level: 12kV ≥42kV/1min (power frequency), ≥75kV (lightning impulse); 40.5kV ≥95kV/1min (power frequency), ≥185kV (lightning impulse)
    • Cabinet material thickness: Cold-rolled steel ≥2mm, Aluminized zinc steel ≥2mm, Stainless steel ≥1.5mm

9.2 Vacuum Circuit Breaker Bid Winning Parameters

    • Rated short-circuit breaking current: ≥20kA
    • Mechanical life: ≥10,000 times (Basic), ≥15,000 times (Standard), ≥20,000 times (Premium)
    • Opening & closing time: Opening ≤0.06s, Closing ≤0.1s

9.3 Microcomputer Protection Device Bid Winning Parameters

    • Measurement accuracy: ≥±0.5% (Basic), ≥±0.2% (Standard), ≥±0.1% (Premium)
    • Communication interfaces: Standard RS485, Standard/Premium equipped with Ethernet, Premium supports IEC61850
    • Protection functions: At least overcurrent, instantaneous trip and zero-sequence protection; Standard/Premium must include differential and breaker failure protection

9.4 Intelligent Monitoring Module Bid Winning Parameters

image

On-Site Arrangement of Switchgear Row

    • Wireless temperature measurement accuracy: ≥±0.5℃ (Basic), ≥±0.3℃ (Premium)
    • Partial discharge sensitivity: ≤10pC (Standard), ≤5pC (Premium)
    • Arc flash protection response time: ≤1ms (Standard), ≤0.5ms (Premium)

10. Full Product Solutions

10.1 Power Distribution Solution for Industrial Enterprises

Pain Points

Large load fluctuation, high short-circuit risk, dense equipment, difficult maintenance, strict power supply reliability requirements

Solution Configuration

12kV/24kV KYN28A series switchgear equipped with differential protection, arc flash protection, wireless temperature measurement and partial discharge monitoring; single busbar sectionalized or double busbar connection with bus coupler automatic transfer; intelligent monitoring platform for remote operation, maintenance and fault early warning

Solution Advantages

High-reliability power supply with complete protection configuration; intelligent monitoring eliminates hidden dangers in advance to reduce shutdown risks; modular design facilitates maintenance and adapts to harsh industrial environments

10.2 Booster Station Solution for New Energy Power Stations

Pain Points

Large voltage fluctuation, high harmonic content, harsh environments (high temperature/humidity/sandstorm), unattended operation, strict grid connection requirements

Solution Configuration

35kV KYN61 series eco-friendly gas insulated switchgear with IEC61850 communication, harmonic protection, frequency protection and grid-connected interface; single busbar or single busbar sectionalized connection, PT cabinet for voltage monitoring and grid connection; intelligent monitoring platform + edge computing for remote monitoring and grid data upload

Solution Advantages

Eco-friendly gas insulation adapts to harsh environments; intelligent protection & monitoring meets grid connection standards; unattended design cuts operation & maintenance costs; high insulation level resists overvoltage impact

10.3 High Voltage Power Distribution Solution for Data Centers

Pain Points

Extremely high power supply reliability requirement (99.999%), high load density, strict power quality demand, fast emergency switching

Solution Configuration

12kV KYN28A series premium intelligent switchgear with dual power redundancy, differential protection, arc flash protection and power quality monitoring; double busbar or ring connection with fast bus coupler transfer; intelligent monitoring platform + video linkage for real-time monitoring and fault location; automatic backup power transfer with switching time ≤0.5s

Solution Advantages

Dual power redundancy realizes zero power failure; fast fault isolation & switching reduces outage risks; power quality monitoring stabilizes precision equipment operation; intelligent operation & maintenance minimizes manual intervention

10.4 Power Distribution Solution for Rail Transit

Pain Points

Severe vibration, strong electromagnetic interference, humid environments, large load fluctuation, strict safety standards

Solution Configuration

12kV/35kV reinforced KYN series switchgear with anti-vibration design, electromagnetic shielding and moisture-proof heating & dehumidification; single busbar sectionalized connection with separated power supply for traction and power loads; intelligent protection & monitoring adapted to vibration environments; “Five Prevention” interlock to guarantee operation safety

Solution Advantages

Reinforced structure resists vibration and electromagnetic interference; moisture-proof design adapts to underground humid environments; safety interlock prevents misoperation; high reliability ensures uninterrupted rail transit power supply

11. Product Application Cases

11.1 10MW Photovoltaic Power Station 35kV Booster Station Project

Project Overview

Located in Northwest China with high temperature and heavy sandstorm; 10MW photovoltaic power station requiring 35kV booster station for grid connection, unattended operation

Equipped Products

KYN61-40.5 eco-friendly gas insulated switchgear (1 incoming cabinet, 2 outgoing cabinets, 1 PT cabinet), ZN85-40.5 vacuum circuit breaker, KZ-300 microcomputer protection, wireless temperature measurement, partial discharge monitoring, intelligent monitoring platform

Project Outcomes

Stable equipment operation adapting to high temperature and sandstorm environments; intelligent monitoring detected 2 insulation hidden dangers in advance to avoid failures; unattended operation reduced O&M costs by 60%; smooth grid connection with annual power generation of 15 million kWh

11.2 12kV Power Distribution Workshop Project for Automobile Manufacturer

Project Overview

Large automobile manufacturer in East China, power distribution workshop power supply with total load 12,000kVA, multiple motors and production lines, high power supply reliability requirements

Equipped Products

KYN28A-12 intelligent switchgear (2 incoming cabinets, 8 outgoing cabinets, 1 bus coupler cabinet, 1 PT cabinet), VS1-12 vacuum circuit breaker, KZ-200 microcomputer protection, arc flash protection, wireless temperature measurement, intelligent monitoring platform

Project Outcomes

Dual power supply + bus coupler automatic transfer achieves power supply reliability of 99.99%; arc flash protection quickly isolates faults to avoid equipment damage; intelligent monitoring early warning improves maintenance efficiency by 50%; guarantees uninterrupted production line operation, reducing annual shutdown losses by over ten million RMB

11.3 12kV High Voltage Power Distribution Project for Large Data Center

Project Overview

Large IDC data center in South China with total load 20,000kVA, dual-circuit high voltage power distribution and strict power quality requirements

Equipped Products

KYN28A-12 premium intelligent switchgear (4 incoming cabinets, 12 outgoing cabinets, 2 bus coupler cabinets, 2 PT cabinets), VS1-12 vacuum circuit breaker, KZ-300 microcomputer protection, power quality monitoring, wireless temperature measurement, partial discharge monitoring, intelligent monitoring platform

Project Outcomes

Dual-circuit redundant power supply realizes zero power outage; power quality monitoring & conditioning stabilizes server operation; intelligent operation & maintenance shortens fault location time by 80%; fully meets high-reliability requirements of data centers and gains high customer recognition

12. Common Product Faults & Maintenance Procedures

12.1 Common Faults & Troubleshooting

Circuit Breaker Faults

  • Phenomenon: Fails to close/open, trips immediately after closing, mechanical jamming
  • Root Causes: Faulty operating mechanism, insufficient energy storage, unlocked interlock, protection activation, mechanical wear
  • Solutions: Inspect operating mechanism and energy storage circuit, release interlock, reset protection device, lubricate mechanical parts; replace circuit breaker if severely damaged

Overheating Faults

  • Phenomenon: Excessively high temperature of contacts/busbars, infrared temperature measurement alarm, accelerated insulation aging
  • Root Causes: Poor contact, overload, poor heat dissipation, excessive ambient temperature
  • Solutions: Power off to inspect contact connections, fasten bolts and remove oxide layers; reduce load and improve ventilation; enhance heat dissipation or derate operation under high temperature

Insulation Faults

  • Phenomenon: Partial discharge, insulation breakdown, earth fault, flashover discharge
  • Root Causes: Insulation aging, dampness, pollution, gas leakage (eco-friendly type), overvoltage impact
  • Solutions: Power off to clean and dry insulation components; replace aged insulation parts; inspect and replenish leaked gas; install lightning arresters to suppress overvoltage

Secondary Circuit Faults

  • Phenomenon: Protection misoperation/rejection, abnormal measurement & control, communication interruption, indicator light failure
  • Root Causes: Loose wiring, oxidized terminals, power supply fault, damaged protection device, faulty communication module
  • Solutions: Inspect and fasten wiring & terminals, clean oxidation; check secondary power supply; reset or replace protection/communication devices; eliminate interference on communication lines

12.2 Daily Maintenance Regulations

Daily Inspection (Remote + On-Site)

  • Remote: Monitor voltage, current, temperature, partial discharge and switch status via monitoring platform for abnormal alarms
  • On-Site: Inspect cabinet appearance, indicator lights, meters, abnormal noise/odor/condensation and reliable earthing

Weekly Maintenance

  • Clean cabinet surface and ventilation openings to remove dust and debris
  • Check normal operation of heating & dehumidifiers and temperature & humidity controllers
  • Fasten secondary circuit terminals to prevent loosening

Monthly Maintenance

  • Infrared temperature measurement: Detect temperature of circuit breaker contacts, busbars and cable terminals, record and analyze data
  • Mechanical inspection: Check operating mechanisms of circuit breakers, disconnectors and earthing switches, lubricate moving parts and verify reliable interlock
  • Protection device: Calibrate protection setting values, check action records and test communication status

Annual Overhaul (Power Cut Required)

  1. Circuit breaker: Disassemble and inspect contacts, arc extinguishing chambers and operating mechanisms; clean, polish and lubricate; test mechanical characteristics (opening/closing time, stroke)
  2. Insulation components: Full cleaning and drying; inspect aging, cracks and damage, replace if necessary
  3. Transformer: Test insulation resistance, transformation ratio and polarity, calibrate accuracy
  4. Earthing system: Test earthing resistance to ensure ≤0.5Ω, verify reliable earthing connections
  5. Intelligent monitoring: Calibrate temperature/partial discharge/arc flash sensors, test alarm and linkage functions

13. Factory Strength & After-Sales Service

13.1 Factory Strength

  • Production Scale: Modern production base covering 50,000㎡ land area and 30,000㎡ building area; multiple flexible production lines with annual output of 10,000 sets high voltage switchgear and 20,000 sets vacuum circuit breakers
  • R&D Team: Over 100 professional R&D personnel including 30 senior engineers and 5 doctors; focus on R&D of high voltage switches, intelligent protection and condition monitoring with over 50 patents
  • Production Equipment: Imported German CNC punching machines, laser cutting machines, bending machines, spraying production lines, vacuum epoxy casting equipment and automatic assembly lines; 80% automation rate guarantees product precision and consistent quality
  • Testing Center: National-level testing laboratory equipped with insulation voltage withstand test bench, short-circuit test device, temperature rise test equipment, partial discharge detector and mechanical characteristic tester; 100% factory type test for all products to ensure qualification
  • Qualification Certifications: ISO9001 quality management system, ISO14001 environmental management system, OHSAS18001 occupational health & safety system certification; products pass national 3C certification, type test certification and CQC certification, complying with national standards GB/T 3906, DL/T 404 etc.

13.2 After-Sales Service System

Service Commitment

  • Warranty Period: 3-year full product warranty, 5-year warranty for core components (circuit breakers, protection devices); free maintenance and component replacement within warranty, free technical support
  • Response Time: 24-hour national service hotline, response within 1 hour; solution provided within 2 hours; on-site arrival within 4 hours for provincial capitals, 8 hours for prefecture-level cities, 24 hours for remote areas
  • Lifelong Service: Lifelong maintenance service after warranty, discounted supply of original spare parts, regular return visits, technical upgrade and renovation service

Service Network

6 regional service centers, 30 provincial service outlets and over 100 authorized service stations nationwide; over 200 professional after-sales engineers with strict training and assessment and rich on-site experience

Service Contents

  1. Installation & Commissioning: Free on-site installation guidance, commissioning and technical training to ensure normal equipment commissioning
  2. Technical Training: Operation, maintenance and fault handling training for customers via online + offline courses to ensure skilled operation of customer staff
  3. Spare Parts Support: National spare parts warehouse with sufficient stock of common spare parts for fast delivery; original direct supply of core components to guarantee compatibility and quality
  4. Upgrade & Renovation: Provide product technical upgrade, intelligent transformation and old equipment replacement services to meet subsequent customer demands

14. Conclusion

With core advantages of high safety, high reliability, intelligence, eco-friendliness, energy saving and flexible customization, KITOZER high voltage switchgear system fully covers all medium-voltage power distribution scenarios of 3.6kV~40.5kV, providing stable and reliable power distribution guarantee for industry, construction, new energy, transportation and other fields. The company possesses strong R&D, production, testing and after-sales service capacity, strictly controls product quality and continuously iterates technology to help customers achieve safe, efficient, intelligent and low-carbon power operation & maintenance targets. In the future, KITOZER will further deepen the medium-voltage power distribution sector, continuously optimize product performance, upgrade service quality and contribute to the development of global power industry.

15. Search Keywords, SEO & Tags

15.1 Search Keywords

High voltage switchgear, 12kV high voltage switchgear, 35kV high voltage switchgear, KYN28A-12, KYN61-40.5, vacuum circuit breaker, microcomputer protection device, intelligent high voltage switchgear, eco-friendly gas insulated switchgear, new energy booster station switchgear, industrial power distribution switchgear, data center high voltage distribution cabinet, KITOZER high voltage switchgear, high voltage switchgear solution, high voltage switchgear configuration list

15.2 SEO Titles

  1. Core Title: KITOZER High Voltage Switchgear System Solution | 12kV/35kV Intelligent Eco-Friendly Power Distribution Equipment
  2. Long-Tail Title: High Voltage Switchgear Dedicated for Industry / New Energy / Data Center | Customized Medium-Voltage Power Distribution Solution

15.3 Tags

#HighVoltageSwitchgear #12kVSwitchgear #35kVSwitchgear #KYN28A #KYN61 #VacuumCircuitBreaker #MicrocomputerProtection #IntelligentPowerDistribution #EcoFriendlyGasInsulated #NewEnergyBoosterStation #IndustrialPowerDistribution #DataCenterPowerDistribution #KITOZER #PowerDistributionSolution

Shopping Cart