KITOZER high voltage voltage detector is a portable handheld tester used by electricians to verify that a circuit is de-energized before touching any conductor during maintenance. The 10kV telescopic model covers distribution voltages from 0.4kV up to 12kV, making it suitable for common industrial and utility switchgear. The detector uses a non-contact capacitive sensing tip that picks up electric field around the conductor, and indicates voltage through a loud buzzer, bright LED strobe, and vibration. The telescopic fiberglass rod extends from 0.6m closed to 1.5m open, keeping the operator at safe distance while reaching busbars and cable terminations. KITOZER supplies the detector in a hard carry case with self-test function and spare battery.
Table of Contents
ToggleProduct Overview
Before any live work or lockout tagout procedure, an electrician must prove the circuit is dead. A visual open switch is not sufficient because of backfeed from another source, cable capacitance, or control supply. The KITOZER voltage detector senses the electric field around an energized conductor and alerts the worker. The self-test button simulates a known field so the operator can confirm the detector works before approaching the circuit. The fiberglass rod provides dielectric insulation between hand and tip, rated for 10kV continuous. The audible and visual alarm works in noisy and dark industrial environments. KITOZER also supplies detectors for 35kV, 110kV, and 220kV systems with longer rods.
Technical Specifications
Voltage range: 0.4kV to 12kV AC. Indication: buzzer 85dB, red LED strobe, vibration. Self-test: built in, battery check. Rod material: epoxy fiberglass, telescopic sections. Closed length: 0.6m. Open length: 1.5m. Dielectric withstand: 40kV per meter for 1 minute. Power: 2 x AA battery, 100 hours continuous. Response time: less than 1 second. Operating temperature: minus 10 to plus 55 degrees Celsius. Protection: IP54. Standards: IEC 61243 part 1, GB. Accessories: hard carry case, calibration certificate, spare battery. KITOZER brand, 2 year warranty, annual calibration recommended.
Applications
The KITOZER 10kV detector is used by electricians to check medium voltage switchgear, transformer primary and secondary bushings, cable terminations, overhead line cutouts, and motor terminal boxes before maintenance. It is part of the lockout tagout procedure in every industrial plant, data center UPS high voltage feed, and building primary substation. Telecom power technicians use it on AC feeders. Solar farm technicians use it on 10kV collection lines. Wind turbine technicians use it on transformer terminals inside the tower base. The detector is also used to trace cable energization when multiple cables enter a junction box and labeling is unclear.
Advantages
Non-contact capacitive sensing means the tip does not need to touch the conductor directly, reducing arc risk. Triple indication (buzzer, strobe, vibration) works in noisy plant rooms and dark cable pits. Telescopic fiberglass rod keeps the operator at arm length distance, improving safety. Self-test function confirms the detector works before use, which is mandatory by safety codes. IP54 rating handles dust and rain in outdoor substations. Light weight body reduces fatigue during long inspection rounds. KITOZER detector comes with a calibration certificate traceable to national standards, required by utility safety audit. The hard case protects the rod from damage during transport.
Installation and Maintenance
Before each use, press the self-test button: buzzer, strobe, and vibration must all activate. If any fail, replace battery or retire the detector. Extend the rod fully, hold the insulated handle, and approach the conductor from a safe angle. If voltage is present, move back immediately. After testing a known live source, verify the detector still alarms, then test the supposed dead circuit, then re-test the known live source to confirm detector functionality throughout. This three step prove test procedure is required by IEC 61243. After use, collapse the rod, wipe the tip clean, remove batteries, and store in the hard case. Send for annual calibration to an approved laboratory. Inspect the fiberglass rod for cracks before each use.
Price
From $85 per detector for 10kV telescopic model. 35kV version from $165. Contact +86 13922289957 for live line tool project pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com