Product Overview

The KITOZER honeycomb waveguide vent panel provides airflow ventilation through a shielded wall while attenuating electromagnetic leakage through the opening. It consists of an array of hexagonal honeycomb cells soldered or brazed into a metal frame. Each cell acts as a below-cutoff waveguide that passes air but strongly attenuates waves above the design cutoff frequency. The result is a low-restriction vent with near-solid shielding performance.

A shielded cabinet must breathe: power supplies and amplifiers generate heat that forced air must carry away. A simple hole in the wall, however, leaks electromagnetic energy just as it lets air pass. The honeycomb vent solves this by breaking the opening into thousands of tiny cells, each too small to pass waves above its cutoff frequency. Air flows through the open area, but high frequency radiation sees a wall.

Technical Specifications

Hex cell size 3.2 mm, 6 mm, or 12 mm across flats. Shielding effectiveness greater than 100 dB from 10 MHz to 1 GHz and greater than 60 dB to 10 GHz for the smallest cell. Cutoff frequency scales inversely with cell size. Air leakage resistance below 30 Pa at rated face velocity. Aluminum or stainless construction with conductive gasket frame. Custom panel sizes to 1200 mm by 2400 mm.

The brazed joints make every cell electrically continuous with the frame, so there are no contact gaps to leak. The aluminum version is light and corrosion resistant; stainless is for high temperature or washdown areas. Cell size is chosen so that the cutoff sits below the lowest frequency that must be blocked, while the open area is maximized for airflow.

Applications

Install in the walls and ceilings of shielded rooms, equipment cabinets, and rack exhausts where forced-air cooling is required. Common in data center containment, EMC chambers, radar equipment bays, and industrial control cabinets that must breathe while maintaining the shield.

A data hall containment uses the vent as the exhaust path while keeping the cold aisle sealed. An EMC chamber uses it as the ventilation opening for the exhaust fan. A radar shelter uses it to cool the transmitter. Wherever a shielded enclosure needs HVAC, the honeycomb panel is the standard ventilation element. Panels can be mounted in the ceiling, the side wall, or the door, depending on the air flow path, and the gasket frame adapts to each orientation. For very large exhaust areas, panels are tiled in a grid with a shared frame, which keeps the installation neat and the shield continuous.

Advantages and Features

The honeycomb geometry maximizes open area while keeping each cell below cutoff, so airflow stays high and pressure drop stays low. The brazed joints provide an electrically continuous panel with no loose contact points. Selecting the correct cell size matches the required shielding band, and the gasket frame bonds to the wall shield without extra sealant.

Because the panel is rigid and metal, it survives years of fan operation without wear. It also requires no power and has no moving parts, so it cannot fail. The panels can be tiled to fill large wall areas and framed to match the cabinet. Because the panel is passive, it introduces no fan noise and no power consumption, which is a benefit in quiet control rooms. The aluminum version is also lightweight enough for wall mounting without structural reinforcement.

Installation and Maintenance

Seal the panel perimeter to the wall with a continuous EMI gasket and bond the frame to the shield. Keep filters upstream of the vent to prevent dust and fibers from plugging the cells. Inspect annually for blocked cells and wash with low-pressure air if needed. Do not bend the thin cell walls.

During install, ensure the gasket is continuous and the frame is bonded on all sides. In dusty plants, inspect the cells quarterly because a plugged panel reduces cooling capacity and can cause equipment overheating. Clean with filtered compressed air rather than liquid, which could leave residue in the tiny cells. When sizing the vent, work backward from the required face velocity: too small a panel forces high velocity through the cells, which raises noise and pressure drop. A slightly larger panel with lower face velocity is quieter and cools better, so over-sizing the vent is usually worth the small extra cost.

Price

From $96 per 600 mm by 600 mm panel. Contact plus 86 13922289957 for custom size and cell selection.