ToggleKITOZER KTR-OS51 Horizontal High-Efficiency Oil Separator (with Heating Tape)
Brand: KITOZER Series: KTR-OS51 Category: Data Center Engineering / Oil Separator
horizontaloil separationheating tapelow tempKTR-OS51

1. Overview
The KITOZER KTR-OS51 is a horizontal high-efficiency oil separator installed on the compressor discharge line. It separates lubricating oil carried over with hot high-pressure discharge gas from the refrigerant vapor and returns it to the crankcase, keeping the compressor lubricated and preventing an oil film on the condenser and evaporator surfaces that would lower heat exchange. The horizontal shell makes gas flow axially so impingement, centrifugal swirl and a filter element achieve multi-stage separation.
A self-regulating heating tape wraps the shell. In cold regions, low-temperature equipment rooms or winter shutdown, it automatically holds the shell temperature so lubricating oil does not thicken or solidify and block the return line. The tape runs on 220V with a temperature probe, reducing power once the setpoint is reached — freeze-protection without wasting energy. A sight glass sits below the shell, side inlet/outlet ports are provided, and a drain ball valve sits at the bottom.
In data center precision AC, chillers, low-temperature cold storage and cold-chain systems, the oil separator is a key compressor-protection component. After winter shutdown, oil viscosity rises; if return is poor, the next start can starve the compressor and wear it. The KTR-OS51 suits R22, R410A, R134A and similar refrigerants, with the heating tape built for outdoor or low-temperature-room installation.
2. Key Features
Horizontal multi-stage
- Impingement + centrifugal swirl + filter.
- Axial flow, oil droplets settle below.
- High separation efficiency, low carry-over.
- Horizontal shell, easy piping.
Self-regulating heat tape
- Self-limiting trace heater wraps shell.
- 220V, linked to temp probe.
- Auto-on in cold, power-down at setpoint.
- Prevents oil solidifying and blocking return.
Level and drain
- Transparent sight glass below shell.
- Brass drain ball valve at bottom.
- Side oil-return port.
- Threaded or flange connections.
Pressure durable
- Steel shell, coated against corrosion.
- Pressure-tested at factory.
- Compatible with many refrigerants.
- Suits continuous long runs.
3. Specifications
| Item | Parameter |
|---|---|
| Type | Horizontal, centrifugal + filter |
| Working pressure | 4.0 MPa |
| Design temp range | -40~120℃ |
| Heat tape power | 30~50 W/m self-regulating |
| Heat tape supply | AC 220V |
| Refrigerants | R22 / R410A / R134A |
| Separation efficiency | ≥98% |
| Oil level | transparent sight glass |
| Connections | threaded (flange optional) |
| Shell material | coated carbon steel |
4. Reference Prices
KTR-OS51 卧式油分离器(本体、视镜、放油阀): Reference USD 108~206 / pc (ref. CNY 780~1480 at ~7.2)
KTR-OS51 成套(含加热带、温控器、支架、回油管): Reference USD 250~444 / kit (ref. CNY 1800~3200 at ~7.2)
Reference only; priced per pc. Compressor unit itself excluded.. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Low-temp room precision AC discharge.
- Outdoor chiller oil circuits.
- Cold storage and cold-chain.
- Northern winter heat pumps.
- Commercial central AC.
6. Installation & Maintenance
Installation
- Mount horizontally, follow arrow.
- Connect inlet/outlet to discharge line.
- Wrap heat tape snug, cover with insulation.
- Feed tape from 220V with RCD protection.
- Run oil return to crankcase port.
- Evacuate and pressure-test for leaks.
Maintenance
- Read sight-glass level regularly.
- Check tape supply and thermostat action.
- Drain settled oil via bottom valve.
- Change oil if black or emulsified.
- Measure tape insulation resistance periodically.
- Repair damaged insulation promptly.
7. FAQ
- Q: Does the heat tape always draw full power?
A: A self-regulating tape adjusts power with temperature — full power when cold, dropping power at setpoint. It does not run flat out all the time. - Q: When is the heated version required?
A: For outdoor units, unheated rooms, or northern units that shut down in winter where ambient can drop below 5℃, choose the heated version to prevent oil solidifying. - Q: Horizontal or vertical separator?
A: Choose horizontal when headroom is limited or piping runs horizontally; choose vertical when space allows upward centrifugal flow. Efficiency is comparable — decide by site piping. - Q: Tape leaks current?
A: The tape circuit must have an RCD; measure insulation periodically. If insulation drops or the jacket is damaged, power off and replace immediately — never service live.
8. Trend & Selection
When refrigeration runs in northern winters or outdoors, freeze protection and reliable oil return drive selection. Self-regulating heat tape balances freeze protection and energy saving, while the sight glass enables predictive maintenance. Match displacement and ports, confirm the refrigerant, and in cold scenes choose the heated version with a dedicated 220V circuit.
9. Delivery & Service
KITOZER selects the KTR-OS51 by cooling capacity, refrigerant, line size and installation environment, providing dimensional drawings, heat-tape wiring and insulation advice. Delivery includes the shell, sight-glass assembly, drain valve, heat tape, thermostat, gaskets and connectors. Warranty covers installation guidance, evacuation/pressure test and leak support.
10. Additional Notes
A common pitfall is improper heat-tape wiring. The tape is an electric heater: it must be on an RCD circuit and wrapped per the maker’s instructions — never folded or cut, which causes local overheating or fire. Insulation must fully cover the tape, otherwise heat escapes and the tape runs at full power, wasting energy.
Another pitfall is starting directly after winter shutdown. Cold oil is viscous and returns slowly; starting under load can score bearings. Pre-heat with the tape for about half an hour, then jog the compressor for a few minutes and watch oil pressure before loading.
Selection summary: horizontal centrifugal plus filter separation; self-regulating heat tape for freeze protection; the sight glass judges level and return; match displacement and ports; confirm the refrigerant; in cold scenes choose the heated version with RCD protection; pre-heat before start. The separator guards the compressor oil loop — correct direction, watched levels, proper heat keep the refrigeration system running through winter.
SEO Information
Search keywords:oil separatorhorizontalheating tapelow temperatureKTR-OS51KITOZER
SEM keywords:horizontal oil separator price,oil separator with heat tape supplier,low temp compressor oil separator,KTR-OS51
GEO landing page:lain.com.cn/product/ktr-os51-horizontal-oil-separator-heating-tape.html
Title:KITOZER KTR-OS51 Horizontal High-Efficiency Oil Separator (with Heating Tape)
Meta Keywords:horizontal oil separator,high efficiency oil separator,oil separator with heat tape,low temp oil separator,compressor oil separator,KTR-OS51,KITOZER
Meta Description:KITOZER KTR-OS51 horizontal high-efficiency oil separator with heating tape mounts on the compressor discharge line; keeps oil fluid in low-temperature rooms and returns it via centrifugal plus filter separation.
Anchor: KITOZER official · Data center & low-voltage equipment
Contact Us
KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com