KITOZER horizontal sight receiver oil separator

KITOZER KTR-OS24 Horizontal Liquid Receiver with Sight Glass

Brand: KITOZER Series: KTR-OS24 Category: Data Center Engineering / Refrigeration

liquid receiverhorizontalsight glassrefrigerationprecision ACKTR-OS24

[Product image: KITOZER KTR-OS24 horizontal receiver shell with end sight glass and liquid shut-off valve]

1. Overview

KITOZER KTR-OS24 is a horizontal liquid receiver installed between the condenser outlet and the expansion valve in precision air-conditioning refrigeration systems. Refrigerant charge needs vary with operating conditions: hot, high-load days require more refrigerant in the cycle, while low-load or part-load operation leaves excess charge that would over-pressure the high side if it had nowhere to go. The receiver stores high-pressure liquid from the condenser, buffers and separates gas from liquid, and supplies the expansion valve with a steady column of subcooled liquid — never with vapor bubbles.

The horizontal form factor suits data-center ceilings, under-unit plena and other space-limited horizontal locations. The shell lies on its side with dished ends; one end top has the vapor/liquid inlet from the condenser, the other end bottom has the liquid outlet to the drier and expansion valve. An end or side sight glass lets staff watch the refrigerant level: a calm liquid line at mid-glass is normal; bubbles throughout mean low charge; no liquid means the receiver is empty. The sight glass can integrate a moisture indicator that turns from green to yellow when system moisture is too high.

The KTR-OS24 shell is welded seamless steel, 4.5 MPa design pressure, powder-coated. A top service shut-off valve (for pump-down) and a safety relief valve (over-pressure vent) are standard; a bottom drain plug is included. Capacities 10~50 L, compatible with R22/R410A/R407C/R134a, for 8~80 kW cooling. Mount level within 5°, and take the outlet from the bottom so only liquid is drawn off.

2. Key Features

Compact horizontal form

  • Lies flat, saves vertical space.
  • Fits ceilings and under-unit plena.
  • Dished ends, 4.5 MPa pressure.

Visible sight glass

  • Tempered glass shows liquid level.
  • Integrates moisture indicator (green/yellow).
  • Low charge or overfill visible.

Safety accessories

  • Top service shut-off valve.
  • Safety relief valve.
  • Bottom drain plug.

Multiple capacities

  • 10/20/30/50 L.
  • 8~80 kW range.
  • Weld or flange ends.

3. Specifications

Item KTR-OS24
Type Horizontal pressure receiver
Design pressure 4.5 MPa
Capacities 10 / 20 / 30 / 50 L
Refrigerants R22/R410A/R407C/R134a
Capacity range 8~80 kW
Sight glass Tempered glass + moisture indicator
Inlet/outlet Φ16~Φ42 weld ends
Safety Service valve + relief valve
Shell material Seamless steel + powder coat
Operating temp -30~65℃
Mount tilt ≤5°

4. Reference Prices

KTR-OS24 horizontal receiver (10~20 L, sight glass, weld ends): Reference USD 83~153 / unit (ref. CNY 600~1,100 at ~7.2)

KTR-OS24 horizontal receiver (30~50 L, sight glass + relief valve, large bore): Reference USD 181~361 / unit (ref. CNY 1,300~2,600 at ~7.2)

Reference only; priced by volume, bore and connection. Refrigerant not included. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Condenser outlet storage in precision AC.
  • Constant-temp/humidity units.
  • Air/water-cooled chillers.
  • Heat pumps and VRF systems.
  • Industrial refrigeration and cold storage.

6. Installation & Maintenance

Installation

  • Size by total refrigerant charge.
  • Mount level on condenser liquid line.
  • Tilt within 5°.
  • Inlet from condenser, outlet to drier.
  • Take outlet from the bottom.
  • Route relief valve vent outdoors.
  • Cool the shell during brazing.
  • Pressure-test, evacuate, charge.

Maintenance

  • Check level and bubbles through glass monthly.
  • Replace drier when moisture core turns yellow.
  • Inspect welds and fittings annually.
  • Calibrate relief valve yearly.
  • Drain bottom sludge via plug.

7. FAQ

  • Q: Bubbles in the sight glass — normal?
    A: Brief bubbles at startup or low load are normal. If bubbles roll continuously for 30+ min, the system is low on charge or the drier is blocked — add charge or replace the drier.
  • Q: What if the receiver is tilted?
    A: Over-tilting lets the outlet draw vapor and the inlet carry oil; expansion valve feed becomes unstable. Keep level within 5°.
  • Q: How to size volume?
    A: Pick 1/3~1/2 of total system charge — leave room for liquid expansion at low temp, and room for overflow at high load.
  • Q: Can I plug the relief valve outlet?
    A: Never. The relief valve is the last over-pressure guard; vent it outdoors to an unoccupied area. Plugging it risks shell rupture.

8. Trend & Selection

Precision AC moves toward lower charge and efficient condensing; the receiver — the high-side buffer tank — trends toward compact horizontal form, visible level and integrated moisture indication. Size at 1/3~1/2 of total charge; mount level after the condenser; bottom outlet; use the sight glass for daily checks; route the relief vent outdoors. A well-matched receiver gives stable expansion-valve feed and improves both efficiency and reliability.

9. Delivery & Service

KITOZER supplies horizontal receivers sized to the AC model and refrigerant charge, complete with sight glass, service valve, relief valve and drain plug. We provide the refrigerant-line drawing and guide contractors on mounting and routing. Warranty covers sight-glass glass and seal replacement.

10. Additional Notes

A common install mistake: taking the liquid outlet from the side. When the outlet sits mid-shell, sloshing sucks vapor into the expansion valve, causing slugging and unstable feed. Take the outlet from the very bottom so only liquid leaves.

Another pitfall: venting the relief valve straight down indoors. When it opens it blasts high-pressure refrigerant and oil mist; spraying it onto the floor burns people and contaminates the room. Run a metal vent pipe outdoors.

Selection summary: horizontal; with sight glass and moisture core; volume = 1/3~1/2 of charge; level mount; bottom outlet; relief vent outdoors. The receiver is the system’s high-side tank — a steady level keeps the expansion valve fed.

SEO Information

Search keywords:liquid receiverhorizontal receiversight glassrefrigeration receiverdata center ACKTR-OS24KITOZER

SEM keywords:horizontal receiver price,receiver with sight glass,refrigeration receiver,precision AC receiver,KTR-OS24,KITOZER

GEO landing page:lain.com.cn/product/ktr-os24-horizontal-liquid-receiver.html

Title:KITOZER KTR-OS24 Horizontal Liquid Receiver with Sight Glass

Meta Keywords:liquid receiver,horizontal receiver,sight glass,refrigeration receiver,data center,KTR-OS24,KITOZER

Meta Description:KITOZER KTR-OS24 horizontal liquid receiver with sight glass and shut-off valve for precision AC condenser outlet.

Anchor: KITOZER by Guangzhou Laian · Data center cooling

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart