KITOZER
KITOZER

KITOZER Humidity Temperature Sensor Room Type For Clean Room

The KITOZER room type humidity and temperature sensor monitors relative humidity and air temperature in offices, clean rooms, museums, and data center corridors. It outputs both parameters on a single device, reducing installation cost versus separate sensors. The capacitive humidity element provides stable readings over years with minimal drift, making it ideal for continuous environmental monitoring.

Product Overview

The sensor is a wall mount plastic enclosure with a removable humidity cap. It includes an LCD display showing current RH and temperature, and optional relays for high or low humidity alarms. Output options include 4 to 20 mA per channel, 0 to 10 V, or Modbus RTU. The wall mount design fits standard electrical boxes.

Technical Specifications

Humidity range 0 to 100 percent RH. Humidity accuracy plus or minus 2 percent RH at 25 C. Temperature range minus 20 C to plus 60 C. Temperature accuracy plus or minus 0.3 C. Output 4 to 20 mA or 0 to 10 V. Power 24 V AC or DC. Enclosure ABS, IP30. Dimensions 90 x 90 x 30 mm. CE certified, 2 year warranty.

Application Scenarios

Install on interior walls at 1.5 m height in occupied zones. The sensor feeds the BMS to control humidifiers, dehumidifiers, and cooling coils. In clean rooms and laboratories, it supports environmental qualification. In museums and archives, it prevents mold growth and material degradation. In data center cold aisles, it maintains ASHRAE recommended humidity band to prevent static and condensation.

Advantages and Features

Capacitive humidity sensor resists condensation and chemicals. LCD display allows local reading without a BMS. Combined sensor reduces wiring and mounting cost. The humidity cap is removable for calibration or replacement. Modbus output enables networked sensor networks. Low power consumption supports long cable runs. Factory calibrated units are ready to install.

Installation and Maintenance

Mount the sensor away from direct sunlight, vents, and external walls. Avoid locations near doors where drafts affect reading. Wire to BMS analog input with shielded cable. Calibrate humidity annually using saturated salt solution reference. Clean the humidity cap with dry air, never with liquid. Replace the sensor element after 5 years or if drift exceeds 3 percent RH.

Price

From $85 per sensor. Contact KITOZER for duct mount and high accuracy versions.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart