The KITOZER room type humidity and temperature sensor monitors relative humidity and air temperature in offices, clean rooms, museums, and data center corridors. It outputs both parameters on a single device, reducing installation cost versus separate sensors. The capacitive humidity element provides stable readings over years with minimal drift, making it ideal for continuous environmental monitoring.
Precise humidity control is critical for comfort, product quality, and equipment reliability. In data centers, too low humidity causes static electricity; too high causes condensation and corrosion. In museums, humidity swings damage artifacts. This sensor provides the feedback needed to keep humidity within design bands.
Table of Contents
ToggleProduct Overview
The sensor is a wall mount plastic enclosure with a removable humidity cap. It includes an LCD display showing current RH and temperature, and optional relays for high or low humidity alarms. Output options include 4 to 20 mA per channel, 0 to 10 V, or Modbus RTU. The wall mount design fits standard electrical boxes.
The humidity element is a capacitive polymer sensor protected by a GORE vent. The temperature element is a NTC or PT1000. The LCD updates every 5 seconds. The relays can be configured for high or low humidity alarms. The enclosure is ABS plastic, white, and blends into office walls.
Technical Specifications
Humidity range 0 to 100 percent RH. Humidity accuracy plus or minus 2 percent RH at 25 C. Temperature range minus 20 C to plus 60 C. Temperature accuracy plus or minus 0.3 C. Output 4 to 20 mA or 0 to 10 V. Power 24 V AC or DC. Enclosure ABS, IP30. Dimensions 90 x 90 x 30 mm. CE certified, 2 year warranty.
Application Scenarios
Install on interior walls at 1.5 m height in occupied zones. The sensor feeds the BMS to control humidifiers, dehumidifiers, and cooling coils. In clean rooms and laboratories, it supports environmental qualification. In museums and archives, it prevents mold growth and material degradation. In data center cold aisles, it maintains ASHRAE recommended humidity band to prevent static and condensation.
In hospitals, it monitors isolation rooms and operating theaters. In pharma, it supports GMP environmental monitoring. In food processing, it controls drying and storage rooms. In offices, it provides comfort feedback for HVAC. The Modbus version supports networked sensor arrays.
Advantages and Features
Capacitive humidity sensor resists condensation and chemicals. LCD display allows local reading without a BMS. Combined sensor reduces wiring and mounting cost. The humidity cap is removable for calibration or replacement. Modbus output enables networked sensor networks. Low power consumption supports long cable runs. Factory calibrated units are ready to install.
Compared with separate humidity and temperature sensors, the combined unit saves half the mounting and wiring cost. The capacitive element is more stable than resistive elements over years. The LCD provides local indication for maintenance staff. The relay outputs enable local alarm logic without BMS.
Installation and Maintenance
Mount the sensor away from direct sunlight, vents, and external walls. Avoid locations near doors where drafts affect reading. Wire to BMS analog input with shielded cable.
Calibrate humidity annually using saturated salt solution reference. Clean the humidity cap with dry air, never with liquid. Replace the sensor element after 5 years or if drift exceeds 3 percent RH. Keep the enclosure closed to protect electronics.