KITOZER
KITOZER

KITOZER Humidity Transmitter: RS485 Modbus Wall Mount

Product Overview

The KITOZER KT-HR10 is a wall-mount humidity and temperature transmitter built for HVAC, cleanrooms, warehouses, and greenhouses. A capacitive polymer sensing element delivers reliable relative humidity readings from 0 to 100 percent, while an integrated NTC measures air temperature from minus 40 to plus 80 degrees Celsius. The unit communicates over RS485 Modbus RTU and optionally provides 4 to 20mA analog outputs for both humidity and temperature. A small, clean ABS enclosure blends into office and factory environments, and the optional local LCD makes commissioning and spot checks faster.

Technical Specifications

Relative humidity range 0 to 100 percent RH, accuracy plus or minus 2 percent RH at 25 degrees Celsius, drift less than 0.5 percent per year. Temperature range minus 40 to plus 80 degrees Celsius, accuracy plus or minus 0.3 degrees Celsius. Response time less than 8 seconds for humidity. Outputs: RS485 Modbus RTU up to 115200 baud, optional 4 to 20mA for RH and temperature. Supply 12 to 24V DC, current draw 25mA. Operating humidity 0 to 100 percent non-condensing. Protection IP30, wall mount, dimensions 86 by 86 by 26 millimeters. CE and RoHS.

Applications

HVAC contractors install the KT-HR10 in ductwork and rooms to modulate cooling and humidification based on comfort requirements. Cleanrooms and pharmaceutical packaging areas use it to validate environmental conditions for GMP compliance. Data centers monitor server inlet humidity to prevent static discharge and equipment corrosion. Warehouses storing electronics, paper, or pharmaceuticals rely on it to trigger alarms when humidity exceeds safe limits. Agricultural greenhouses and livestock barns also use the Modbus output to link climate control strategies into a centralized controller.

Advantages and Features

The KITOZER KT-HR10 uses a calibrated capacitive sensor with a filter cap that protects against dust and splashes, while still allowing fast air exchange. The Modbus register map is documented and easy to integrate into any BMS or PLC. A simple two-wire bus daisy-chains up to 32 transmitters on one RS485 segment, saving cable compared with analog-only devices. The optional LCD shows RH, temperature, and dew point in one glance, and the unit supports user-selectable averaging to smooth out rapid door-opening transients. KITOZER backs the transmitter with a 3 year warranty and offers replacement filters and calibration services.

Installation and Maintenance

Mount the transmitter on an interior wall at breath height, away from direct sunlight, radiators, windows, and air vents that would bias the reading. Use shielded twisted pair for the RS485 bus, and keep it separate from mains wiring. Terminate the bus at the last device with a 120 ohm resistor. Set the Modbus address and baud rate using the configuration cable provided. To maintain accuracy, avoid painting over the sensor cap or touching the element. Recalibrate every 12 months using a saturated salt salt chamber or return the unit to KITOZER for NIST-traceable calibration. Replace the sintered filter annually in dusty environments.

Reliability and Testing

The KT-HR10 sensor is calibrated at 33, 75, and 95 percent RH against saturated salt solutions, and the electronics are EMC tested to EN 61326. The capacitive element recovers within 30 minutes after 100 percent RH condensation, and drift under normal use is less than 0.5 percent per year. The enclosure is UV stabilized, suitable for office and factory wall mounting.

Industry Standards and Compliance

The KT-HR10 is CE marked, RoHS compliant, and meets EN 61326-1 for EMC. The humidity element is factory calibrated against a Vaisala HMP7 reference, and the calibration uncertainty is plus or minus 2 percent RH. The Modbus implementation follows the Modbus Organization application note. The ABS enclosure is UL94 V-0 flame rated. KITOZER supplies a 3.1 calibration certificate and offers annual recalibration with a fast turn-around service.

Why Choose KITOZER

KITOZER humidity transmitters use a calibrated Sensirion-class element and ship with a point-to-point calibration report. The Modbus register map is documented in a free PDF, and integrators can copy and paste registers into their PLC tag database. Compared with building-management system brands, KITOZER offers 70 percent lower pricing with the same 2 percent RH accuracy. The wall-mount enclosure blends into offices and cleanrooms, and the optional LCD shows dew point at a glance. KITOZER supports a 3 year warranty and offers annual recalibration with a pre-paid shipping label.

Warranty and Support

The KT-HR10 carries a 3 year warranty and ships with a point-to-point calibration certificate. KITOZER provides free Modbus register support and sample PLC code for common BMS platforms. Spare transmitters and filter caps are stocked for next-day shipment. Annual recalibration is offered with a pre-paid return label. Technical support is available by phone, WeChat, and email, and responds within 4 business hours. Volume discounts apply for orders above 50 units.

Price

From $58/pc including mounting bracket. Contact +86 13922289957 for duct-mount and high-temperature versions.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com