KITOZER
KITOZER

KITOZER Hydrant Pump: 20L/s 0.9MPa For Indoor Hydrant Networks

KITOZER indoor hydrant pump model HP-20-09 is a vertical line-shaft turbine or horizontal end-suction unit selected to feed indoor hydrant risers in mid-rise and high-rise buildings. The pump delivers 20 liters per second at 0.90 megapascal discharge pressure, sized for two simultaneous hydrant hose streams of 5 L/s each at the highest floor plus margin for riser friction. The wet end is cast iron with bronze impeller, and the motor is a 37 kilowatt Class F IP55 unit mounted on a common baseplate. The set is delivered with a jockey pump of 1 L/s, pressure switches, relief valve, test header, and a hydrant-specific control panel with fire-alarm panel interlock.

Product Overview

The HP-20-09 is designed for indoor hydrant systems in buildings where the municipal supply cannot provide the required pressure at the highest floor. The pump starts automatically when the hydrant riser pressure drops below the cut-in set point, or when the fire alarm panel sends a manual start signal from a hydrant box button. The control panel includes pressure switch start, remote start from hydrant boxes, hand-off-auto selector, running and fault lamps, and RS485 Modbus for BMS integration. KITOZER tunes the pressure set points to the building hydraulic calculation, typically cut-in at 0.75 megapascal and cut-out at 0.95 megapascal, and supplies a suction tank of 18 cubic meters when municipal water is insufficient.

Technical Specifications

Rated flow 20 L/s equal to 72 cubic meters per hour. Rated head 90 meters equal to 0.90 megapascal. Shut-off head 120 meters. Bronze impeller, 300 millimeters. Inlet DN100 PN16. Outlet DN80 PN16. Motor power 37 kilowatt, 380 volt three phase, 50 hertz. Speed 2950 rpm. Mechanical seal. Pump efficiency at BEP 76 percent. NPSH required 4.0 meters. Jockey pump 1 L/s at 100 meters head. Baseplate common steel. Motor IP55 Class F. Pressure switches two independent. Relief valve set at 1.1 times rated head. Test header DN50. Control panel star-delta, IP42, with remote start input from hydrant boxes and RS485. Certifications CCCF, ISO 9001, GB 50974. Warranty 24 months from commissioning.

Application Scenarios

This pump is specified for indoor hydrant systems in office towers, residential high-rises, hotels, hospital buildings, school campuses, underground parking, and shopping malls. The 20 L/s flow covers two 65 millimeter hose streams at 5 L/s each at the highest floor, plus margin for riser friction. It pairs with a 18 cubic meter suction tank when municipal pressure is marginal, or directly with a municipal connection sized for 20 L/s. MEP consultants select this model when the highest-floor hydrant nozzle requires 0.25 megapascal residual pressure and the building is over 50 meters tall.

Advantages and Features

The vertical or horizontal configuration options fit tight pump rooms. The jockey pump maintains static pressure, eliminating frequent main pump starts. Remote start from hydrant box buttons ensures the pump runs even if the pressure switch fails. The compact 37 kilowatt motor fits standard building power. KITOZER tunes the pump curve to the riser calculation, guaranteeing nozzle pressure at the highest floor. The skid arrives pre-piped, reducing field labor. The control panel includes weekly exercise timer for motor health.

Installation and Maintenance Recommendations

Install on a level concrete foundation. Keep suction pipe straight for at least five diameters. Maintain suction tank level with low-level alarm. Ventilate the room. Conduct weekly pressure switch start test, monthly flow test at the header, and annual full-flow witness. Verify hydrant box remote start circuit continuity annually. Inspect jockey pump seal quarterly. Clean suction strainer monthly. Log every run. Replace relief valve seat every 5 years. Keep spare pressure switch on site.

System Integration

The HP-20-09 hydrant pump connects to each riser through a discharge check valve and isolation butterfly valve, so a single riser can be serviced without draining the whole system. Each hydrant box on every floor includes a manual start button that closes a dry contact into the pump control panel, allowing the fire brigade to start the pump from the point of attack. The panel also receives a signal from the building fire alarm panel to start the pump on any confirmed fire. Suction is drawn from a dedicated fire water tank sized for 2 hours of flow at 20 L/s, typically 144 cubic meters, with a low-level alarm and a make-up float valve connected to the municipal supply. KITOZER coordinates the suction tank volume, riser sizing, and nozzle pressure calculation so the delivered package satisfies the local fire authority on first review. The set is delivered with suction strainer, eccentric reducer, isolation valves, and discharge check valve, so the MEP contractor only needs to connect the riser and power supply.

Price

From 3,800 US dollars per complete hydrant pump skid including main pump, jockey pump, baseplate, piping, valves, gauges, and starter panel. Contact KITOZER for riser hydraulic review and factory lead time.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart