KITOZER IG541 inert gas fire suppression system model IG-15 uses a mixture of 52 percent nitrogen, 40 percent argon, and 8 percent carbon dioxide to extinguish fire by reducing oxygen concentration below the level that sustains combustion. Because the agent is simply compressed atmospheric gases, IG541 leaves zero residue, zero ozone depletion potential, and zero greenhouse warming contribution, making it the preferred clean agent for environmentally sensitive projects and LEED-certified buildings. Each 15 megapascal cylinder stores 6.2 cubic meters of gas at NTP, discharged through high-pressure piping to achieve 37.5 to 43 percent design concentration in the protected enclosure within 60 seconds.
Table of Contents
ToggleProduct Overview
The KITOZER IG-15 system comprises cylinders manifolded on a common high-pressure rail, a pilot-operated master valve, solenoid release, flexible hoses, check valves, discharge piping, calibrated nozzles, detection, and a gas suppression control panel. Because the agent is stored at 15 megapascal, the cylinders are smaller than equivalent HFC systems but require thicker piping and special high-pressure fittings. The control panel provides cross-zone smoke and heat detection, 60-second pre-discharge delay for personnel egress, audible and visual alarms, abort switch, and interfaces with HVAC shutdown and door holders. Multiple cylinder groups can be sequenced for very large enclosures.
Technical Specifications
Agent mixture 52 percent nitrogen, 40 percent argon, 8 percent carbon dioxide. Cylinder volume 80 liters. Storage pressure 15 megapascal at 20 degrees Celsius. Gas volume per cylinder 6.2 cubic meters at NTP. Design concentration 37.5 to 43 percent by volume. Discharge time 60 seconds. Cylinder material manganese steel tested to 22.5 megapascal. Valve pilot operated, solenoid 24 volt DC. Piping high-pressure steel, schedule 80, threaded or welded. Nozzle pressure range 2.0 to 6.0 megapascal. Control panel two detection circuits, cross-zone, 60 second delay, abort, RS485. Certifications CCCF, ISO 9001, NFPA 2001, GB 25972. Cylinder hydro test 5 years. Warranty 24 months from commissioning.
Application Scenarios
IG541 is specified for electrical switchrooms, transformer bays, UPS and battery rooms, data center server halls, control rooms, museum galleries, library archives, and telecommunications equipment rooms where long-term environmental stewardship is a project requirement. Because the discharge time is 60 seconds, the protected space must be tightly sealed with a verified leakage rate. Typical cylinder count for a 200 cubic meter room at 40 percent concentration is 14 cylinders. Engineers select IG541 when HFCs are excluded by corporate environmental policy or local regulation, and when the room can tolerate a 60-second discharge window.
Advantages and Features
IG541 is zero-ODP and zero-GWP, satisfying the most demanding green building standards. The mixture includes 8 percent carbon dioxide to stimulate breathing in the low-oxygen atmosphere, making the system safe for the evacuation delay period. The agent leaves no residue and no cleanup. High-pressure storage allows smaller cylinder footprint than lower-pressure alternatives. The system is accepted by major insurance loss-prepection agencies. KITOZER provides full hydraulic calculation of the 15 megapascal piping network, ensuring nozzle pressure and concentration uniformity.
Installation and Maintenance Recommendations
Install cylinders upright in a ventilated enclosure away from direct sunlight. Verify room enclosure integrity with a door fan test per NFPA 2001. Install pressure relief vent panels rated for the discharge overpressure. Inspect cylinder pressure gauge monthly; a 10 percent pressure drop requires recharge. Test detection circuits semi-annually. Hydrostatically test cylinders every 5 years. Keep spare solenoid coils, seals, and nozzle orifice plates on site. Train staff on abort procedure and manual release. Log every inspection.
System Integration
The IG-15 control panel coordinates with the building fire alarm, HVAC shutdown, door holder release, and pressure vent panel actuators. Because the discharge time is 60 seconds, the pre-discharge delay is typically 60 seconds to allow full egress from the low-oxygen atmosphere. The panel includes a dedicated oxygen depletion warning lamp outside the protected room, and a manual release box for trained response personnel. The high-pressure piping network is calculated per NFPA 2001 to ensure nozzle pressure stays above the minimum atomization threshold. KITOZER provides a hydraulic calculation report, concentration map across the room, and an enclosure integrity test protocol, so the system is accepted by the fire authority on first witness. The panel communicates via RS485 with the BMS, reporting each alert level, fault, and discharge event for the facility log. Because the agent is simply compressed air, post-discharge recovery is limited to airing the room and recharging cylinders, with no cleanup residue and no corrosion concern on electrical contacts. The mixture includes 8 percent carbon dioxide to stimulate breathing during the egress delay, so personnel can evacuate safely without self-contained breathing apparatus. The high-pressure cylinders are hydrostatically tested every 5 years per local regulation, and KITOZER provides the test schedule as part of the commissioning dossier.
Price
From 4,200 US dollars per 80 liter charged 15 megapascal cylinder including valve and mounting. Complete system quoted per room hydraulic calculation. Contact KITOZER for sizing.