KITOZER Immersion Liquid Cooling Cabinet

KITOZER Immersion Liquid Cooling Cabinet Quotation List

2. Project Requirement Description

This quotation addresses the following project requirements:

  • Target scenarios: Ultra-high-density computing environments, including AI large model training, high-performance computing (HPC), and computing power nodes requiring over 40kW per single cabinet.
  • Solution approach: Provide a single-phase immersion liquid cooling cabinet solution where IT equipment is fully submerged in insulating coolant.
  • Cooling objective: Achieve ultimate heat dissipation efficiency, solving the chip cooling challenge under ultra-high heat flux density.
  • Efficiency target: Support PUE reduction to below 1.05, suitable for new high-density liquid-cooled data center projects.

3. System Composition Introduction

The immersion liquid cooling cabinet system consists of the following main components:

  • 304 stainless steel immersion tank body
  • Sealed top cover assembly
  • Supply/return liquid interface module
  • Liquid level monitoring system
  • Temperature monitoring array
  • Leak detection system
  • Visual touchscreen display
  • Cabinet outer frame support structure
  • Exhaust and liquid replenishment assembly
  • Electrical isolation module
  • Installation and sealing accessories

All units undergo complete factory tank sealing tests and performance calibration prior to shipment.

4. Core Product Specifications & Parameters

Parameter Technical Specification
Cabinet specification 42U immersion tank, external dimensions 1300mm (W) × 1500mm (D) × 2100mm (H)
Tank material Food-grade 304 stainless steel, 3mm thickness, argon arc welding, fully sealed without leakage
Rated cooling capacity 48kW, peak support 60kW
Working temperature Supply liquid 35–45°C, return liquid 45–55°C
Coolant compatibility Compatible with fluorinated fluids, mineral oil and other insulating coolants; tank volume ≥1200L
Monitoring parameters Multi-point real-time monitoring of liquid level, temperature, flow, and pressure; temperature accuracy ±0.5°C
Protection rating Liquid cooling area IPX7, electrical area IP40
Equipment compatibility Supports standard 19-inch servers for direct immersion deployment without structural modification
Sealing performance Helium leak detection process, annual leakage rate ≤0.1%

5. Core Functions & Features of Products

Core Functions:

  • Immersion cooling function: Servers are fully submerged in insulating coolant; heat is transferred directly through liquid conduction with zero contact thermal resistance, achieving ultimate cooling efficiency.
  • Liquid level management: Real-time monitoring of coolant level, automatic low-level alarm, and replenishment prompts to ensure stable system operation.
  • Temperature regulation: Multi-point temperature acquisition combined with circulation system for precise supply liquid temperature control, keeping equipment in the optimal operating temperature range.
  • Safety protection: Fully sealed tank design with non-conductive insulating coolant; multiple leak detection and anti-overflow designs eliminate safety hazards.
  • Status visualization: Touchscreen display provides real-time operating parameters, alarm information, and operation logs for intuitive O&M.
  • Compatibility & expansion: Supports different server specifications and can interface with various liquid cooling source systems, adapting to clusters of different scales.

Core Features:

  • Extreme cooling density: Up to 60kW heat dissipation per cabinet, 5–8 times higher than traditional air cooling, greatly improving data center space utilization.
  • Ultra-high energy efficiency: PUE as low as 1.03–1.10, reducing cooling energy consumption by over 50%, significantly lowering operating costs.
  • High reliability: Full immersion isolates equipment from dust, humidity, and oxidation, extending hardware lifespan by over 25%.
  • Low noise operation: No cooling fans; overall operating noise ≤50dB, improving the data center O&M environment.
  • Standardized delivery: Factory-prefabricated tank and monitoring system; on-site connection to cold source and coolant refill enables rapid deployment.

6. Core Advantages of The Solution

  • Performance advantage: Direct contact heat exchange with zero thermal resistance easily handles ultra-high heat flux density exceeding 1kW per single chip, compatible with next-generation high-power computing chips.
  • Cost advantage: Long-term electricity costs are greatly reduced, and data center air conditioning investment decreases; full lifecycle TCO is significantly superior to air-cooled solutions.
  • Process advantage: Integrated welded stainless steel tank with helium leak detection ensures sealing reliability; service life ≥15 years.
  • O&M advantage: Modular design supports hot-swappable equipment maintenance; coolant remains stable long-term, requiring only inspection and replenishment every 3–5 years.
  • Customization advantage: Supports customization of tank dimensions, power ratings, monitoring functions, and coolant types to match different project requirements.

7. Manufacturer Strength Introduction

KITOZER (Guangzhou Lai’an Intelligent System Development Co., Ltd.) is a professional manufacturer of intelligent cooling and data center infrastructure equipment. Established in 2002, the company is certified under ISO 9001, ISO 14001, and ISO 45001, and is recognized as a national high-tech enterprise. As a manufacturer, KITOZER maintains complete quality inspection procedures before shipment and has a proven track record in delivering reliable liquid cooling solutions to data center projects worldwide. The company operates under its own independent brand, KITOZER, and is committed to continuous R&D innovation in immersion and cold-plate liquid cooling technologies.

8. Detailed Quotation Table

No. Product Name Model & Spec Technical Parameter Qty Unit Unit Price (USD) Total Price (USD) Brand Remark
1 304 Stainless Steel Immersion Tank KTR-IMT-48K 42U capacity, 1300×1500×2100mm tank body, 3mm thick 304 stainless steel, helium leak detection process 1 unit 39,958.56 39,958.56 KITOZER Main tank, integrated welded construction
2 Sealed Top Cover Assembly KTR-IMT-COVER Reinforced steel structure, EPDM sealing strip, locking mechanism, tempered glass observation window 1 set 7,991.71 7,991.71 KITOZER IPX7 sealing
3 Supply/Return Liquid Interface Module KTR-IMT-IF02 DN50 standard interface, integrated regulating valve, exhaust valve, pressure gauge, quick coupling 1 set 3,329.88 3,329.88 KITOZER Bottom dual-side liquid inlet/outlet
4 High-Precision Liquid Level Monitoring System KTR-IMT-LV01 Multi-point liquid level sensor, detection accuracy ±1mm, high/low dual-threshold alarm 1 set 2,663.90 2,663.90 KITOZER Real-time liquid level monitoring
5 Multi-Point Temperature Monitoring Array KTR-IMT-TM08 8-channel temperature acquisition, multi-point arrangement in supply/return lines and tank, accuracy ±0.5°C 1 set 1,997.93 1,997.93 KITOZER Temperature gradient monitoring
6 Double-Layer Bottom Leak Detection System KTR-IMT-LD02 Double-layer liquid receiving bottom chamber, immediate leakage detection, audible/visual alarm output 1 set 1,553.94 1,553.94 KITOZER Dual leak protection
7 10-inch Industrial Touchscreen Display KTR-IMT-DS10 Front door embedded installation, parameter display, alarm query, parameter configuration, log export 1 unit 2,219.92 2,219.92 KITOZER Human-machine interface terminal
8 Heavy-Duty Cabinet Outer Frame Support Structure KTR-IMT-FRAME Carbon steel powder-coated outer frame, static load capacity ≥3000kg, with leveling support feet 1 set 5,327.81 5,327.81 KITOZER Tank load-bearing structure
9 Exhaust & Liquid Replenishment Integrated Assembly KTR-IMT-BF01 Integrated filling port, exhaust valve, coolant filter device, convenient O&M 1 set 1,331.95 1,331.95 KITOZER Daily maintenance accessory
10 Electrical Isolation Protection Module KTR-IMT-EL01 Strong/weak current separation design, waterproof wiring terminal block, insulation protection class IP40 1 set 1,109.96 1,109.96 KITOZER Electrical safety protection
11 Installation & Sealing Accessory Kit KTR-IMT-A01 Special seals, fasteners, stainless steel pipe fittings and other installation accessories 1 set 1,775.94 1,775.94 KITOZER On-site installation accessory

Total Quotation Price: USD 69,261.50

9. Quotation Terms & Conditions

  • Currency & base price: All prices are quoted in USD, EXW Guangzhou, China.
  • Tax note: Quoted prices exclude tax and freight. A VAT special invoice requires an additional 10% tax charge; a VAT general invoice requires an additional 3% tax charge.
  • Payment terms: 30% deposit upon order confirmation, 70% balance before shipment (negotiable for specific projects).
  • Lead time: 15–30 working days depending on configuration and quantity.
  • Validity period: This quotation remains valid for 30 days from the date of issue.
  • Shipping: Transportation via logistics carrier, freight collect. Goods may be picked up by the buyer at the factory or delivery can be negotiated on-site.
  • Packing: Standard export packing is included; special packing requirements are quoted separately.

10. After-sales Service Description

  • Warranty: 12–24 months product warranty depending on component configuration (standard configuration: 1 year full warranty).
  • Lifetime support: Lifetime technical support and spare parts supply are guaranteed for all KITOZER products.
  • Technical services: Remote troubleshooting available; on-site commissioning, maintenance, and training services can be arranged as needed.
  • Spare parts: Genuine KITOZER spare parts are available for the full lifecycle of the product.

11. Contact & Order Information

  • Order channel: Place orders via the official website gdlain.com or contact the KITOZER sales team directly.
  • Manufacturer: Guangzhou Lai’an Intelligent System Development Co., Ltd. / Guangdong Lai’an Intelligent Computer Room Equipment Co., Ltd.
  • Brand: KITOZER
  • Response commitment: All inquiries receive a response within 24 hours.
  • Address: Chaotian Park, Zhongrun Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China.

12. SEO Keywords & Tags

immersion liquid cooling cabinet, single-phase immersion liquid cooling, server immersion liquid cooling cabinet, fluorinated fluid immersion cabinet, 48kW immersion cooling cabinet, AI computing immersion liquid cooling cabinet, high-density data center liquid cooling cabinet, low PUE immersion cabinet, KITOZER immersion liquid cooling cabinet, KITOZER quotation, immersion liquid cooling cabinet price list, immersion liquid cooling cabinet factory price, wholesale immersion liquid cooling cabinet quotation, Guangzhou immersion liquid cooling manufacturer, KITOZER liquid cooling equipment