KITOZER 10kW in-row precision air conditioner sits directly between server racks in a hot-aisle cold-aisle layout, pulling hot exhaust air from the rear of the rack row and discharging cooled air into the cold aisle. By placing cooling close to the heat source, the in-row unit eliminates long airflow paths and avoids hot spots that commonly occur with room-based precision units. The narrow 300-millimeter-wide cabinet fits into a standard 19-inch rack row, allowing operators to add cooling incrementally as IT load grows.
Table of Contents
ToggleProduct Overview
The in-row unit integrates a brushless DC scroll compressor, electronic expansion valve, EC plug fan, and optional humidifier in a rack-height enclosure. A color touch-screen controller displays supply and return temperatures, fan speed, compressor runtime, and alarms. The fan draws hot aisle air from the rear and pushes cold air into the cold aisle, creating a short, controlled airflow loop. Modbus TCP and SNMP support integration with DCIM platforms for real-time thermal monitoring.
Technical Specifications
Cooling capacity 10kW at 27 degrees Celsius DB, 50 percent RH. Air-cooled with remote condenser. Airflow 2600 cubic meters per hour. Power supply 220V single phase or 380V three phase. Cabinet width 300 millimeters, depth 1200 millimeters, height 2000 millimeters. Temperature control plus or minus 1 degree Celsius. Noise below 62 decibels at one meter. CE certified. KITOZER brand. Five year compressor warranty.
Applications
Suited for high-density compute clusters, GPU rendering nodes, VDI farms, and small colocation cages where rack density exceeds 6kW. The in-row approach works well in existing rooms that cannot support a raised floor plenum. It is also ideal for retrofit projects where adding ceiling ducted cooling would require major renovation.
Advantages
Close-coupled cooling eliminates hot spots and improves IT reliability. Modular scaling lets operators add one unit at a time. High sensible heat ratio minimizes overcooling. Low sound level allows installation near open-office areas. The unit shares refrigerant infrastructure with other KITOZER in-row units, simplifying condenser selection.
Installation and Maintenance
Align the unit flush with rack fronts and seal gaps with brush strips. Route refrigerant piping through the overhead cable tray or under-floor conduits. Program the controller to stagger fan speeds for quiet night operation. Replace filters quarterly. Inspect the remote condenser coil annually. Verify that hot-aisle containment seals are intact.
Price: From $5,400/pc. Contact +86 13922289957 for in-row AC pricing.