KITOZER in-row air conditioner is a rack-height cooling unit installed between server racks in a contained aisle, delivering cold air directly to the rack fronts and pulling hot air from the rear. By placing cooling close to the heat source, the in-row unit eliminates long supply paths and the associated fan energy, and it handles high density racks that perimeter CRAH units cannot. The 30 kW model described here is sized for a pair of 8 to 12 kW racks, or for a short row of 6 to 8 racks at 4 kW each. It supports chilled water, direct expansion, and dual coolant configurations, and it integrates with DCIM platforms via Modbus TCP.
Table of Contents
ToggleProduct Overview
The in-row unit is the same width as a standard server rack (600 or 800 mm) and sits in the rack row, so it does not consume extra floor space. Front discharge blows cold air into the contained cold aisle, and rear intake draws hot exhaust from the hot aisle. A variable speed EC fan modulates airflow based on aisle temperature, and a modulating water valve or electronic expansion valve regulates cooling output. The controller displays supply and return temperature, setpoint, alarm history, and fan speed on a 7 inch touchscreen. The unit is available in chilled water, direct expansion with external condensing unit, and refrigeration only variants.
Technical Specifications
Cooling capacity: 30 kW sensible at 24 C entering, 50 percent RH, 7/12 C chilled water. Airflow: 6,000 m3/h variable. External static pressure: up to 75 Pa. Dimensions: 600 W x 1100 D x 2000 H mm. Weight: 220 kg chilled water, 260 kg DX. Compressor: rotary or scroll, inverter driven on DX variants. Fan: EC plug fan, speed 400 to 1800 RPM, 2.0 kW max. Coil: copper tubes, aluminum fins, 6 rows chilled water, 4 rows DX. Filter: G4 washable. Power supply: 230 V single phase 50 Hz. Controls: 7 inch HMI, Modbus TCP, BACnet option, SNMP option. Alarms: high temperature, filter dirty, fan fault, water leak. Operating temperature 18 to 35 C, humidity 20 to 80 percent.
Applications
In-row units are deployed in high density racks, GPU and AI compute clusters, VDI farms, and colocation cages where customers pay by power and densities vary. They are also used in retrofits where adding perimeter CRAH units is impossible due to floor space or floor loading limits. They pair naturally with cold aisle containment or hot aisle containment, because the unit sits inside the row and air is contained on both sides. Typical customers include cloud service operators, financial trading firms, engineering simulation labs, and broadcast playout centers. The units are also used in modular data centers where the cooling is integrated into the row.
Advantages and Features
The main advantage is proximity to heat. Because cold air travels less than 2 meters from unit to rack, there is no mixing, no hot spot, and no need to oversize. The EC fans save 30 percent energy compared to fixed speed units at part load. Modulating valves and expansion valves allow precise temperature control within plus or minus 1 C. The unit is N plus 1 redundant when two units serve one aisle, because either unit alone can carry the aisle load. Front service means the unit can be maintained without pulling it out of the row. The touchscreen HMI simplifies local troubleshooting. Because the unit is rack width, it fits existing rack rows without redesigning the room.
Installation and Maintenance
The unit is forklifted into position in the rack row, leveled, and secured to the floor or to adjacent racks. Water connections are made on the rear or bottom, and power and network cables are routed through the row cable tray. Commissioning takes two hours per unit: the engineer sets supply temperature setpoint, configures alarm thresholds, and verifies Modbus communication. Maintenance is quarterly: inspect filter, clean coil fins with low pressure air, check water connections for leaks, and test the fan speed modulation. Annually, inspect the compressor on DX units, test the condensate drain, and verify alarm contacts. Filters are washable and last 2 to 3 years. Spare filters and sensors ship from stock.
Warranty and Support
KITOZER warrants the in-row air conditioner for 3 years on compressor and coil, and 2 years on controller and sensors. Factory commissioning is included in the price, with engineers on site for two days to verify airflow, water valves, and alarm integration. The unit is shipped with a full operation manual, electrical schematic, and BMS point list in English. Spare filters, sensors, and contactors are stocked regionally, and the EC fan can be replaced without draining the water circuit. Remote diagnostics via Modbus TCP allow the service team to read fault codes before dispatching a technician, cutting mean time to repair.
Price
From $6,800 per chilled water in-row unit, from $8,900 per DX in-row unit. External condensing unit priced separately. Contact +86 13922289957 for quotation.