Toggle1. System Overview
KITOZER in-row air conditioners (also known as aisle air conditioners) are precision temperature control equipment specially developed for high-density data centers, modular computer rooms and high heat density cabinet scenarios. Adopting embedded installation between cabinet rows and horizontal front air supply & rear air return design, they are deployed close to IT heat sources to shorten cold air transmission distance, completely resolving pain points of traditional room-level air conditioners such as mixed cold and hot air flow, prominent local hot spots and high energy consumption.
The system integrates constant temperature & humidity, air purification, intelligent control, remote monitoring and other functions, adapting to scenarios with single cabinet heat load above 5kW. Cooperated with hot and cold aisle containment technology, it realizes precise temperature control (22±1°C) and constant humidity (50%±5% RH), significantly reducing computer room PUE. It serves as the core temperature control solution for energy-saving green data centers.
In-row Air Conditioner for Computer Room
2. System Composition
The KITOZER in-row air conditioning system consists of five core modules: refrigeration circulation system, air circulation system, temperature & humidity control system, intelligent monitoring system and auxiliary functional system. All modules work in coordination to guarantee stable and efficient system operation.
- Refrigeration Circulation System: Core components include full DC inverter scroll compressor, high-efficiency evaporator, electronic expansion valve, condenser and refrigerant pipeline, responsible for heat exchange and cold energy generation. The inverter compressor adjusts cooling capacity on demand to adapt to dynamic heat loads.
- Air Circulation System: Composed of EC energy-saving fans, high-grade air filters, air duct assemblies and air supply/return vents. EC fans feature stepless speed regulation with large air volume and small enthalpy difference design, achieving sensible heat ratio above 90% to efficiently remove cabinet heat. Filters are available in G4/F7/H13 grades to purify computer room air.
- Temperature & Humidity Control System: Including high-precision temperature & humidity sensors, PTC heaters, electrode/ultrasonic humidifiers and intelligent controllers. It collects environmental parameters in real time and automatically switches refrigeration, heating and humidification modes to maintain constant computer room temperature and humidity.
- Intelligent Monitoring System: Integrated with main control unit, communication modules (Modbus/SNMP/BACnet), touch display screen and remote monitoring terminals. It supports local parameter setting, operation status display, real-time remote monitoring, fault alarms and remote parameter configuration.
- Auxiliary Functional System: Comprising drainage assemblies, lightning protection, overload protection, phase sequence protection, seismic base and mute noise reduction components. It ensures safe and stable system operation, lowers failure risks and adapts to complex computer room environments.
CAD Layout Drawing of In-row Air Conditioner
3. System Classification
KITOZER in-row air conditioners are classified by four dimensions: refrigeration mode, structural size, functional configuration and cooling medium, covering full scenarios from low to high heat density.
3.1 Classification by Refrigeration Mode
- Air-cooled Direct Expansion In-row Air Conditioner: Built-in compressor and air-cooled condenser, independent operation without external chilled water, easy to install. Suitable for small & medium high-density computer rooms and modular computer rooms, cooling capacity range: 9kW–55kW.
- Water-cooled Direct Expansion In-row Air Conditioner: Connected to external cooling towers for heat dissipation via cooling water circulation with high heat exchange efficiency. Suitable for large data centers and ultra-high heat density cabinets (above 15kW per cabinet), cooling capacity range: 20kW–80kW.
- Chilled Water In-row Air Conditioner: Connected to centralized chilled water system without built-in compressors, exchanging heat via chilled water with ultra-low energy consumption. Suitable for newly-built large data centers and park-level computer rooms, cooling capacity range: 15kW–60kW.
- Dual-Cooling-Source In-row Air Conditioner: Integrates direct expansion and chilled water dual systems. The chilled water system runs preferentially for energy saving under normal conditions, and automatically switches to direct expansion system upon failure to guarantee uninterrupted cooling. Suitable for critical business computer rooms in finance, medical and other industries.
3.2 Classification by Structural Size
- 300mm Narrow Body Type: 300mm width, fits standard cabinet spacing to save computer room space, cooling capacity 9kW–25kW, ideal for medium & low heat density cabinet scenarios.
- 600mm Wide Body Type: 600mm width with large heat exchange area, cooling capacity 25kW–55kW, suitable for high-density cabinets with single cabinet heat load above 10kW.
Production Workshop of In-row Air Conditioners
3.3 Classification by Functional Configuration
- Basic Type (Low Configuration): Only equipped with refrigeration and basic temperature control, G4 filtration, no humidification or heating modules. Suitable for computer rooms with stable environment that only require cooling.
- Standard Type (Medium Configuration): Integrated with refrigeration, constant temperature & humidity, F7 filtration, EC fans and local touch control. Suitable for most small & medium data centers and modular computer rooms.
- High-end Type (High Configuration): Full functional configuration including refrigeration, constant temperature & humidity, H13 high-efficiency filtration, full DC inverter, intelligent networking, remote monitoring, fault self-recovery and heat recovery modules. Suitable for large data centers, AI computing power rooms and critical business computer rooms.
3.4 Classification by Air Supply Mode
- Horizontal Front Supply & Rear Return: Standard configuration, cold air delivered from the front of cabinets and hot air returned from the rear. Optimal air flow organization for hot & cold aisle containment scenarios.
- Horizontal Side Supply & Side Return: Adapts to special cabinet layouts and space-limited scenarios with adjustable air supply & return vent directions.
4. System Schematic Principle
4.1 Working Principle of Air-cooled Direct Expansion In-row Air Conditioner
- Refrigeration Cycle: The compressor compresses low-temperature low-pressure refrigerant into high-temperature high-pressure gas, which liquefies after heat dissipation via the condenser. The liquid refrigerant passes through the electronic expansion valve for throttling and pressure reduction, enters the evaporator to absorb computer room heat and evaporate into gas, then flows back to the compressor to complete the cycle.
- Air Circulation: EC fans draw hot air from the computer room into the air conditioner. After cooling and dehumidification by the evaporator, cold air is sent to the cold aisle in front of cabinets to cool IT equipment. Hot air after heat exchange flows back to the air conditioner from rear return vents for cyclic operation.
- Control Logic: Temperature & humidity sensors collect computer room parameters in real time. The controller automatically adjusts compressor frequency, fan speed and expansion valve opening according to set values to realize precise constant temperature & humidity control.
4.2 Working Principle of Chilled Water In-row Air Conditioner
- Refrigeration Cycle: The centralized chilled water system delivers 7°C chilled water to the air conditioner evaporator for heat exchange with hot computer room air, and 12°C return water flows back to the chiller for re-cooling circulation.
- Air Circulation & Control Logic: Consistent with air-cooled direct expansion type, without built-in compressors, featuring lower energy consumption and more stable operation relying on chilled water heat exchange.
On-site Installation of In-row Air Conditioners
4.3 System Architecture Diagram
5. Full System Configuration List (Low / Medium / High Three Grades)
5.1 Low Configuration – Basic Type Configuration List
è¡¨æ ¼
| No. | Product Name | Model & Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Air-cooled Direct Expansion In-row Air Conditioner Main Unit | KZ-XJ-F09 | Cooling capacity: 9kW; Air volume: 3000m³/h; Size: 2000×300×1200mm; Power supply: 380V/3PH/50Hz; Fan: EC fan; Filtration: G4; No humidification/heating; Temperature control range: 18–28°C | 1 | Set | KITOZER | 300mm narrow body, basic cooling |
| 2 | Outdoor Air-cooled Condenser | KZ-LN-F09 | Matches 9kW main unit; Heat exchange area: 8㎡; Fan: fixed-frequency axial fan; Protection grade: IP54 | 1 | Set | KITOZER | Supporting heat dissipation for main unit |
| 3 | Refrigerant Pipeline | KZ-GL-01 | Copper tube Φ12mm; Insulation thickness: 10mm; Temperature resistance: -40℃~120℃ | 1 | Set | KITOZER | Including joints and thermal insulation cotton |
| 4 | Air Filter | KZ-GL-G4 | Grade G4; Size: 280×1100mm; Filtration efficiency: ≥90% (5μm) | 2 | Pcs | KITOZER | Built-in main unit, replaceable |
| 5 | Intelligent Controller | KZ-CON-B | Touch screen; Local temperature control; Fault alarm; Modbus support; Operating voltage: 24VDC | 1 | Pcs | KITOZER | Built-in main unit |
| 6 | Drainage Assembly | KZ-PS-01 | Drainage pump; Lift: 5m; Drain pipe Φ20mm; Material: PVC | 1 | Set | KITOZER | Condensate drainage |
| 7 | Seismic Base | KZ-DZ-01 | Size: 300×1200mm; Load capacity: 500kg; Material: galvanized steel plate; Shockproof rubber mat | 1 | Pcs | KITOZER | Main unit fixing & shock absorption |
5.2 Medium Configuration – Standard Type Configuration List
è¡¨æ ¼
| No. | Product Name | Model & Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Air-cooled Direct Expansion In-row Air Conditioner Main Unit | KZ-XJ-F25 | Cooling capacity: 25kW; Sensible heat ratio: 92%; Air volume: 5000m³/h; Size: 2000×300×1200mm; Power supply: 380V/3PH/50Hz; Compressor: full DC inverter scroll; Fan: EC variable frequency; Filtration: F7; Humidification: electrode type (3kg/h); Heating: PTC (6kW); Temp control: 22±1℃; Humidity control: 50%±5% RH | 1 | Set | KITOZER | 300mm narrow body, constant temperature & humidity |
| 2 | Outdoor Air-cooled Condenser | KZ-LN-F25 | Matches 25kW main unit; Heat exchange area: 18㎡; Fan: variable frequency axial fan; Protection grade: IP54; Low noise ≤55dB | 1 | Set | KITOZER | Variable frequency energy saving, low noise |
| 3 | Refrigerant Pipeline | KZ-GL-02 | Copper tube Φ19mm; Insulation thickness: 15mm; Temperature resistance: -40℃~120℃; Flame retardant grade: B1 | 1 | Set | KITOZER | Including joints, insulation cotton and fixing brackets |
| 4 | Air Filter | KZ-GL-F7 | Grade F7; Size: 280×1100mm; Filtration efficiency: ≥95% (1μm) | 2 | Pcs | KITOZER | Built-in main unit, washable |
| 5 | Electrode Humidifier | KZ-JS-D3 | Humidification capacity: 3kg/h; Power: 2.2kW; Power supply: 220V; Water quality requirement: ordinary tap water | 1 | Set | KITOZER | Built-in main unit, automatic humidification |
| 6.1 | PTC Heater | KZ-JR-P6 | Heating power: 6kW; 3-section segmented control; Open-flame free; Safety protection: overheat/overload | 1 | Set | KITOZER | Built-in main unit, low temperature compensation |
| 6.2 | Intelligent Controller | KZ-CON-S | 7-inch touch screen; Local & remote control; Precise temperature & humidity control; Fault record; Modbus/SNMP support; Operating voltage: 24VDC | 1 | Pcs | KITOZER | Built-in main unit, intelligent regulation |
| 7 | Drainage Assembly | KZ-PS-02 | Drainage pump; Lift: 8m; Drain pipe Φ25mm; Material: stainless steel + PVC; Water level alarm equipped | 1 | Set | KITOZER | Automatic condensate drainage |
| 8 | Seismic Base | KZ-DZ-02 | Size: 300×1200mm; Load capacity: 800kg; Material: galvanized steel plate; Thickened shockproof rubber mat; Anti-corrosion coating | 1 | Pcs | KITOZER | Main unit fixing & shock absorption |
| 9 | Communication Module | KZ-TX-01 | Modbus/SNMP support; RJ45 interface; Transmission distance: 1000m; Operating temperature: -10℃~60℃ | 1 | Pcs | KITOZER | Remote monitoring docking |
5.3 High Configuration – High-end Type Configuration List
è¡¨æ ¼
| No. | Product Name | Model & Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Dual-Cooling-Source In-row Air Conditioner Main Unit | KZ-XJ-S50 | Cooling capacity: 50kW (30kW direct expansion + 20kW chilled water); Sensible heat ratio: 95%; Air volume: 9000m³/h; Size: 2200×600×1200mm; Power supply: 380V/3PH/50Hz; Compressor: full DC inverter scroll; Fan: dual EC variable frequency fans; Filtration: H13; Humidification: ultrasonic (6kg/h); Heating: PTC (12kW); Temp control: 22±0.5℃; Humidity control: 50%±3% RH; Heat recovery: 10kW; Fault self-recovery | 1 | Set | KITOZER | 600mm wide body, full-function dual cooling source |
| 2 | Outdoor Air-cooled Condenser | KZ-LN-S30 | Matches 30kW direct expansion system; Heat exchange area: 25㎡; Fan: variable frequency silent axial fan; Protection grade: IP55; Low noise ≤50dB; Anti-corrosion coating | 1 | Set | KITOZER | High-efficiency heat dissipation, low noise & anti-corrosion |
| 3 | Chilled Water Interface Assembly | KZ-LS-01 | Matches 20kW chilled water system; Inlet/outlet water: 7℃/12℃; Pipe diameter: DN40; Pressure resistance: 1.6MPa; Equipped with electric two-way valve | 1 | Set | KITOZER | Connect to centralized chilled water system |
| 4 | Refrigerant Pipeline | KZ-GL-03 | Copper tube Φ28mm; Insulation thickness: 20mm; Temperature resistance: -40℃~150℃; Flame retardant grade: A1; Built-in pressure monitoring | 1 | Set | KITOZER | Including joints, insulation cotton and pressure sensors |
| 5 | Air Filter | KZ-GL-H13 | Grade H13; Size: 580×1100mm; Filtration efficiency: ≥99.97% (0.3μm) | 2 | Pcs | KITOZER | Built-in main unit, high-efficiency purification |
| 6 | Ultrasonic Humidifier | KZ-JS-C6 | Humidification capacity: 6kg/h; Power: 3kW; Power supply: 220V; Precise humidity control; No-water protection | 1 | Set | KITOZER | Built-in main unit, silent humidification |
| 7 | PTC Heater | KZ-JR-P12 | Heating power: 12kW; 4-section intelligent control; Open-flame free; Overheat/overload/leakage protection | 1 | Set | KITOZER | Built-in main unit, precise low temperature compensation |
| 8 | Intelligent Controller | KZ-CON-H | 10-inch touch screen; Local/remote/cluster control; High-precision temperature & humidity control; Fault early warning & self-recovery; Energy consumption statistics; Modbus/SNMP/BACnet support; Operating voltage: 24VDC | 1 | Pcs | KITOZER | Built-in main unit, full intelligent management & control |
| 9 | Drainage Assembly | KZ-PS-03 | Drainage pump; Lift: 12m; Drain pipe Φ32mm; Material: 304 stainless steel; Water level alarm & fault reporting | 1 | Set | KITOZER | High-efficiency condensate drainage |
| 10 | Seismic Base | KZ-DZ-03 | Size: 600×1200mm; Load capacity: 1500kg; Material: thickened galvanized steel plate; High-strength shockproof rubber mat; Anti-rust & anti-corrosion coating | 1 | Pcs | KITOZER | Main unit fixing, shock absorption & anti-tilting |
| 11 | Communication Networking Module | KZ-TX-02 | Modbus/SNMP/BACnet support; RJ45+RS485 dual interfaces; Cluster networking; Remote upgrade; Operating temperature: -20℃~70℃ | 1 | Pcs | KITOZER | Multi-unit networking, remote operation & maintenance |
| 12 | Heat Recovery Assembly | KZ-HR-01 | Heat recovery capacity: 10kW; Heat exchange efficiency: ≥85%; Recover computer room waste heat in winter for auxiliary heating / fresh air preheating | 1 | Set | KITOZER | Energy saving & consumption reduction, lower PUE |
| 13 | Lightning Protection Assembly | KZ-FL-01 | Primary power lightning protection + signal lightning protection; Lightning protection grade: IP65; Response time: ≤25ns | 1 | Set | KITOZER | Prevent lightning damage to equipment |
6. Full Product Technical Parameters
Computer Room Layout CAD Drawing
6.1 KZ-XJ-F09 (Low Configuration Air-cooled Direct Expansion Main Unit)
- Cooling capacity: 9kW (return air 37℃/RH25%)
- Air volume: 3000m³/h (fixed-speed EC fan)
- Size (H×W×D): 2000×300×1200mm
- Weight: 180kg
- Power supply: 380V/3PH/50Hz, rated power: 3.5kW
- Compressor: fixed-frequency scroll type, COP≥2.8
- Fan: EC energy-saving fan, noise ≤55dB
- Filtration grade: G4 (washable)
- Temperature control range: 18–28℃ (accuracy ±1℃)
- Humidity control: no humidification (only monitoring)
- Protection grade: IP20 (indoor unit)
- Operating environment: -10℃~40℃ (indoor)
6.2 KZ-XJ-F25 (Medium Configuration Air-cooled Direct Expansion Main Unit)
- Cooling capacity: 25kW (return air 37℃/RH25%), sensible heat ratio: 92%
- Air volume: 5000m³/h (adjustable EC variable frequency fan)
- Size (H×W×D): 2000×300×1200mm
- Weight: 280kg
- Power supply: 380V/3PH/50Hz, rated power: 8.5kW
- Compressor: full DC inverter scroll type, COP≥3.2
- Fan: EC variable frequency energy-saving fan, noise ≤52dB
- Filtration grade: F7 (high-efficiency washable)
- Temperature control: 22±1℃ (accuracy ±0.5℃)
- Humidity control: 50%±5% RH (electrode humidifier, 3kg/h)
- Heating power: 6kW (segmented PTC heating)
- Protection grade: IP21 (indoor unit)
- Operating environment: -15℃~45℃ (indoor)
On-site Pipeline Installation
6.3 KZ-XJ-S50 (High Configuration Dual-Cooling-Source Main Unit)
- Cooling capacity: 50kW (30kW direct expansion + 20kW chilled water), sensible heat ratio: 95%
- Air volume: 9000m³/h (dual adjustable EC variable frequency fans)
- Size (H×W×D): 2200×600×1200mm
- Weight: 480kg
- Power supply: 380V/3PH/50Hz, rated power: 15kW (direct expansion part)
- Compressor: full DC inverter scroll type, COP≥3.5
- Fan: dual EC variable frequency energy-saving fans, noise ≤50dB
- Filtration grade: H13 (high-efficiency purification, filtration efficiency 99.97%)
- Temperature control: 22±0.5℃ (accuracy ±0.2℃)
- Humidity control: 50%±3% RH (ultrasonic humidifier, 6kg/h)
- Heating power: 12kW (4-section intelligent PTC heating)
- Heat recovery capacity: 10kW (heat exchange efficiency ≥85%)
- Protection grade: IP22 (indoor unit)
- Operating environment: -20℃~50℃ (indoor)
Monitoring Control Center
6.4 Outdoor Air-cooled Condenser (KZ-LN-F09/F25/S30)
è¡¨æ ¼
| Model | Matched Main Unit | Heat Exchange Area (㎡) | Fan Type | Protection Grade | Noise (dB) | Operating Environment |
|---|---|---|---|---|---|---|
| KZ-LN-F09 | KZ-XJ-F09 | 8 | Fixed-frequency axial fan | IP54 | ≤58 | -30℃~50℃ |
| KZ-LN-F25 | KZ-XJ-F25 | 18 | Variable frequency axial fan | IP54 | ≤55 | -35℃~55℃ |
| KZ-LN-S30 | KZ-XJ-S50 | 25 | Variable frequency silent axial fan | IP55 | ≤50 | -40℃~60℃ |
6.5 Core Accessory Parameters
- Electrode Humidifier (KZ-JS-D3): Humidification capacity 3kg/h, power 2.2kW, 220V, operating temperature 5–40℃
- Ultrasonic Humidifier (KZ-JS-C6): Humidification capacity 6kg/h, power 3kW, noise ≤45dB, no-water protection
- PTC Heater (KZ-JR-P6/P12): Power 6kW/12kW, 380V, open-flame free, overheat & overload protection
- Intelligent Controller (KZ-CON-B/S/H):
- Low configuration: touch screen, local temperature control, Modbus, 24VDC
- Medium configuration: 7-inch touch screen, remote control, precise temperature & humidity regulation, Modbus/SNMP
- High configuration: 10-inch touch screen, cluster control, fault self-recovery, energy consumption statistics, Modbus/SNMP/BACnet
- Air Filter (G4/F7/H13):
- G4: efficiency ≥90% (5μm), washable
- F7: efficiency ≥95% (1μm), washable
- H13: efficiency ≥99.97% (0.3μm), high-efficiency purification
7. Full Product Application Scope
Data Center Control Room
7.1 Air-cooled Direct Expansion In-row Air Conditioner (KZ-XJ-F09/F25)
- Small & medium high-density data centers: single cabinet heat load 5kW–15kW, 10–50 cabinets
- Modular computer rooms / micro-modules: standard cabinet layout, space-limited, rapid deployment required
- Old computer room renovation: upgrade traditional room-level air conditioners to eliminate local hot spots and reduce energy consumption
- Edge computing rooms: base station computer rooms, park edge computer rooms with complex environments and difficult maintenance
- Communication computer rooms: program-controlled switching rooms, satellite communication stations requiring constant temperature & humidity for stable equipment operation
7.2 Dual-Cooling-Source In-row Air Conditioner (KZ-XJ-S50)
- Large data centers / AI computing power rooms: single cabinet heat load above 15kW, GPU server clusters, ultra-high density computing scenarios
- Finance / medical critical business computer rooms: bank core computer rooms, hospital data centers requiring 7×24h uninterrupted cooling with zero shutdown risk
- Park-level data centers: matched with centralized chilled water systems for energy saving, green data centers with PUE ≤1.2 requirements
- Container data centers: outdoor deployment, compact space, high heat density, adapting to extreme ambient temperatures
- Scientific research laboratory computer rooms: high-precision temperature control (±0.5℃) and constant humidity (±3% RH) to guarantee stable operation of precision instruments
7.3 Chilled Water In-row Air Conditioner (Matched with KZ-XJ-S50)
- Newly-built large data centers: matched with centralized chillers for large-scale deployment and ultra-low energy consumption requirements
- Cloud computing data centers: multi-tenant, dynamic heat loads requiring flexible cooling capacity allocation with energy saving priority
7.4 Application Scope of Core Accessories
3D Rendering of Computer Room Layout
- Full-function constant temperature & humidity: Integrated humidification and heating modules, optimal cost performance for most small & medium data rooms requiring temperature & humidity control.
- Inverter energy saving with low operating cost: Full DC inverter compressor + EC variable frequency fans, energy saving rate over 25% compared with fixed-frequency models, low long-term operating cost.
- Intelligent monitoring & remote management: Standard Modbus/SNMP communication protocol, docking with computer room monitoring system for remote monitoring and fault alarms, reducing labor maintenance costs.
8.4 Exclusive Advantages of High Configuration Model (KZ-XJ-S50)
- Dual cooling source redundancy with zero shutdown risk: Automatic switch between direct expansion and chilled water dual systems, single system failure will not affect overall operation, suitable for critical business computer rooms.
- Full intelligent management & fault self-recovery: 10-inch touch screen, cluster control, fault early warning, automatic diagnosis and self-repair without manual intervention, improving maintenance efficiency by 80%.
- High-efficiency purification for high cleanliness: H13 air filter with 99.97% filtration efficiency for particles above 0.3μm, adapting to scientific research and medical computer rooms with high cleanliness requirements.
- Heat recovery energy saving & environmental protection: Built-in heat recovery assembly recovers computer room waste heat in winter for auxiliary heating or fresh air preheating, further reducing PUE and complying with green data room standards.
8.5 Bid-winning Parameter Requirements (Marked with *)
-
- In-row air conditioners adopt embedded installation between cabinet rows with horizontal front supply & rear return air design, optional width 300mm/600mm.
-
- Cooling capacity range: low configuration 9kW, medium configuration 25kW, high configuration 50kW (dual cooling source); sensible heat ratio ≥92% (medium & high configuration).
-
- Compressors adopt full DC inverter scroll type (medium & high configuration), COP≥3.2 (medium configuration), COP≥3.5 (high configuration).
-
- Fans adopt EC variable frequency energy-saving fans with stepless speed regulation, noise ≤52dB (medium configuration), ≤50dB (high configuration).
-
- Air filtration grade: low configuration G4, medium configuration F7, high configuration H13 (filtration efficiency ≥99.97%).
-
- Temperature control accuracy: medium configuration ±0.5℃, high configuration ±0.2℃; humidity control accuracy: medium configuration ±5% RH, high configuration ±3% RH.
-
- Supported communication protocols: Modbus/SNMP (medium configuration), Modbus/SNMP/BACnet (high configuration).
-
- High configuration models integrate dual cooling source systems with automatic switching function, heat recovery capacity ≥10kW.
-
- Units support full front maintenance without reserved side/rear maintenance space.
-
- Indoor unit operating temperature range -20℃~50℃, outdoor unit -40℃~60℃.
9. Full Product Bid-winning Parameter List
è¡¨æ ¼
| No. | Product Name | Bid-winning Parameters (Marked with *) |
|---|---|---|
| 1 | Air-cooled Direct Expansion In-row Main Unit (Low Configuration KZ-XJ-F09) | * Cooling capacity: 9kW; * Air volume: 3000m³/h; * Size: 2000×300×1200mm; * Compressor: fixed-frequency scroll type, COP≥2.8; * Filtration: G4; * Protection grade: IP20; * Operating environment: -10℃~40℃ |
| 2 | Air-cooled Direct Expansion In-row Main Unit (Medium Configuration KZ-XJ-F25) | * Cooling capacity: 25kW, sensible heat ratio ≥92%; * Air volume: 5000m³/h; * Size: 2000×300×1200mm; * Compressor: full DC inverter scroll type, COP≥3.2; * Fan: EC variable frequency, noise ≤52dB; * Filtration: F7; * Temp control: ±0.5℃, humidity control: ±5% RH; * Communication: Modbus/SNMP; * Protection grade: IP21; * Operating environment: -15℃~45℃ |
| 3 | Dual-Cooling-Source In-row Main Unit (High Configuration KZ-XJ-S50) | * Cooling capacity: 50kW (30kW direct expansion + 20kW chilled water), sensible heat ratio ≥95%; * Air volume: 9000m³/h; * Size: 2200×600×1200mm; * Compressor: full DC inverter scroll type, COP≥3.5; * Fan: dual EC variable frequency, noise ≤50dB; * Filtration: H13 (efficiency ≥99.97%); * Temp control: ±0.2℃, humidity control: ±3% RH; * Heat recovery capacity: ≥10kW; * Communication: Modbus/SNMP/BACnet; * Protection grade: IP22; * Operating environment: -20℃~50℃ |
| 4 | Outdoor Air-cooled Condenser (KZ-LN-F09) | * Matches 9kW main unit; * Heat exchange area ≥8㎡; * Fan: fixed-frequency axial fan; * Protection grade: IP54; * Noise ≤58dB; * Operating environment: -30℃~50℃ |
| 5 | Outdoor Air-cooled Condenser (KZ-LN-F25) | * Matches 25kW main unit; * Heat exchange area ≥18㎡; * Fan: variable frequency axial fan; * Protection grade: IP54; * Noise ≤55dB; * Operating environment: -35℃~55℃ |
| 6 | Outdoor Air-cooled Condenser (KZ-LN-S30) | * Matches 30kW main unit; * Heat exchange area ≥25㎡; * Fan: variable frequency silent axial fan; * Protection grade: IP55; * Noise ≤50dB; * Operating environment: -40℃~60℃ |
| 7 | Electrode Humidifier (KZ-JS-D3) | * Humidification capacity ≥3kg/h; * Power ≤2.2kW; * Operating temperature: 5–40℃ |
| 8 | Ultrasonic Humidifier (KZ-JS-C6) | * Humidification capacity ≥6kg/h; * Power ≤3kW; * Noise ≤45dB; * No-water protection function |
| 9 | PTC Heater (KZ-JR-P6) | * Heating power 6kW; * Open-flame free; * Overheat/overload protection function |
| 10 | PTC Heater (KZ-JR-P12) | * Heating power 12kW; * 4-section intelligent control; * Overheat/overload/leakage protection function |
| 11 | Intelligent Controller (KZ-CON-H) | 10-inch touch screen; cluster control; * Fault self-recovery; * Energy consumption statistics; * Modbus/SNMP/BACnet support |
10. Full Product Solutions
10.1 Medium & Low Heat Density Computer Room Solution (Low Configuration KZ-XJ-F09)
- Applicable Scenarios: Single cabinet heat load below 5kW, 10–30 cabinets, small & medium computer rooms and edge computing rooms with limited budgets only requiring cooling.
- Solution Configuration: 1 set KZ-XJ-F09 main unit + 1 set KZ-LN-F09 condenser for every 10 cabinets, N configuration (no redundancy), matched with basic hot & cold aisle containment.
- Solution Advantages: Economical and practical, fast deployment within 1 day; simple maintenance with low cost; meets basic cooling demand and eliminates local hot spots.
- Implementation Key Points: Main units installed side by side with cabinets with spacing ≤100mm; cold aisle containment rate ≥80%; outdoor condensers installed in well-ventilated unobstructed areas.
10.2 Medium & High Heat Density Computer Room Solution (Medium Configuration KZ-XJ-F25)
- Applicable Scenarios: Single cabinet heat load 5kW–15kW, 30–50 cabinets, small & medium data centers, modular computer rooms and old computer room renovation requiring constant temperature & humidity and intelligent monitoring.
- Solution Configuration: 1 set KZ-XJ-F25 main unit + 1 set KZ-LN-F25 condenser for every 8–10 cabinets, N+1 redundant configuration; standard F7 filtration, electrode humidification and PTC heating; docking with computer room monitoring system for remote management.
- Solution Advantages: Precise constant temperature & humidity control to guarantee stable equipment operation; inverter energy saving with low long-term operating cost; intelligent monitoring for remote operation & maintenance to cut labor costs; N+1 redundancy avoids overall shutdown caused by single unit failure.
- Implementation Key Points: Full hot & cold aisle containment (containment rate ≥95%); main units precisely aligned with cabinets, air supply vents facing cabinet air inlets; outdoor condensers reserved maintenance space, fan air outlet avoiding prevailing wind direction.
10.3 Ultra-High Heat Density / Critical Business Computer Room Solution (High Configuration KZ-XJ-S50)
- Applicable Scenarios: Single cabinet heat load above 15kW, GPU server clusters, finance/medical critical business computer rooms, large AI computing power rooms requiring zero shutdown and low PUE green data center standards.
- Solution Configuration: 1 set KZ-XJ-S50 dual-cooling-source main unit + 1 set KZ-LN-S30 condenser for every 5–8 cabinets, N+1 dual cooling source redundancy; integrated H13 filtration, ultrasonic humidification and heat recovery assemblies; multi-unit networking, cluster control and fault self-recovery.
- Solution Advantages: Dual cooling source redundancy with zero shutdown risk; full intelligent management improving maintenance efficiency; high-efficiency purification to guarantee computer room cleanliness; heat recovery energy saving reducing PUE to below 1.2; adapts to ultra-high heat density scenarios to resolve high-density cabinet heat dissipation challenges.
- Implementation Key Points: Full hot & cold aisle containment + aisle access control; independent wiring for chilled water and direct expansion systems with automatic switching logic testing; heat recovery assemblies linked with fresh air systems for waste heat recovery in winter; anti-corrosion coating on outdoor condensers adapting to harsh outdoor environments.
10.4 Chilled Water System Supporting Solution (High Configuration KZ-XJ-S50)
- Applicable Scenarios: Newly-built large data centers and park-level computer rooms matched with centralized chillers for large-scale deployment and ultra-low energy consumption requirements.
- Solution Configuration: KZ-XJ-S50 main unit chilled water interface connected to centralized chillers (7℃ supply / 12℃ return water); direct expansion system as backup with automatic switching upon failure; multi-unit networking with unified monitoring and flexible cooling capacity allocation on demand.
- Solution Advantages: Ultra-low energy consumption of chilled water system, energy saving rate over 40% compared with direct expansion system; centralized management for easy maintenance; backup direct expansion system guarantees uninterrupted cooling; adapts to large-scale data center deployment to lower overall PUE.
11. Full Product Application Cases
11.1 Edge Computing Room Project in Guangzhou (Low Configuration KZ-XJ-F09)
- Project Overview: 80㎡ computer room, 20 cabinets, single cabinet heat load 4kW, limited budget, demand to eliminate local hot spots.
- Solution Adopted: 2 sets KZ-XJ-F09 in-row air conditioners (N configuration) + basic hot & cold aisle containment.
- Implementation Effect: Installation completed within 1 day for rapid deployment; computer room temperature stabilized at 22–26℃ with complete elimination of local hot spots; operating energy consumption reduced by 35% compared with original room-level air conditioners, annual maintenance cost cut by 40%, meeting budget and cooling requirements.
11.2 Modular Data Center Project in Shenzhen (Medium Configuration KZ-XJ-F25)
- Project Overview: 200㎡ modular computer room, 40 cabinets, single cabinet heat load 10kW, demand for constant temperature & humidity and intelligent monitoring to guarantee stable server operation.
- Solution Adopted: 5 sets KZ-XJ-F25 in-row air conditioners (N+1 redundancy), F7 filtration, electrode humidification and PTC heating; docking with computer room monitoring system for remote management.
- Implementation Effect: Computer room temperature & humidity stabilized at 22±1℃, 50%±5% RH to meet server operating standards; N+1 redundant design with zero shutdown failures in 2 years of operation; inverter energy saving reduced PUE to 1.35, energy saving rate 30% vs traditional schemes; remote monitoring cut labor maintenance cost by 50%.
11.3 AI Computing Power Room Project in Beijing (High Configuration KZ-XJ-S50)
- Project Overview: 500㎡ AI computing power room, 60 cabinets, single cabinet heat load 20kW, GPU server clusters, demand for zero shutdown, low PUE and high cleanliness environment.
- Solution Adopted: 12 sets KZ-XJ-S50 dual-cooling-source in-row air conditioners (N+1 redundancy), H13 filtration, ultrasonic humidification and heat recovery assemblies; multi-unit cluster control with fault self-recovery, docking with centralized chilled water system.
- Implementation Effect: Computer room temperature & humidity stabilized at 22±0.5℃, 50%±3% RH, cleanliness reaching ISO Class 7; dual cooling source redundancy achieved zero shutdown in 3 years of operation to guarantee uninterrupted AI computing business; heat recovery + chilled water system reduced PUE to 1.18, meeting green data center standards; intelligent cluster control improved maintenance efficiency by 80%, annual energy cost cut by 45%.
11.4 Financial Core Computer Room Renovation Project in Shanghai (High Configuration KZ-XJ-S50)
- Project Overview: Old financial computer room renovation, 300㎡ area, 35 cabinets, single cabinet heat load 18kW, demand for 7×24h uninterrupted cooling with zero shutdown risk to stabilize financial transactions.
- Solution Adopted: 8 sets KZ-XJ-S50 dual-cooling-source in-row air conditioners (N+1 redundancy), dismantling original traditional room-level air conditioners and renovating hot & cold aisles; integrated fault self-recovery and remote early warning functions.
- Implementation Effect: 15-day renovation without interrupting existing business; precise temperature & humidity control with no local hot spots; automatic dual cooling source switching achieving zero failure shutdown in 2.5 years of operation to secure financial transactions; energy consumption reduced by 40% and maintenance cost cut by 35% post-renovation, meeting high reliability requirements of financial industry.
12. Full Product Fault Troubleshooting & Maintenance
12.1 Common Faults & Solutions
12.1.1 Insufficient Cooling Capacity
- Fault Causes: Clogged filters, low fan speed, refrigerant leakage, poor condenser heat dissipation, compressor failure.
- Solutions: Replace/clean filters; inspect EC fans and adjust speed; test refrigerant pipelines for leakage and recharge refrigerant; clean condenser dust and guarantee ventilation; inspect, repair or replace compressors.
12.1.2 Abnormal Temperature & Humidity
- Fault Causes: Failed temperature & humidity sensors, damaged humidifiers/heaters, incorrect controller parameter settings, clogged humidification/heating pipelines.
- Solutions: Replace sensors; inspect humidifiers/heaters and replace damaged components; reset controller parameters; unclog humidification/heating pipelines.
12.1.3 Fan Not Running
- Fault Causes: Fan power failure, burnt fan motor, abnormal controller signals, fan overload protection trigger.
- Solutions: Inspect power wiring and repair power supply faults; replace fan motor; test controllers and repair signal transmission; restart fans and troubleshoot overload causes.
12.1.4 Water Leakage
- Fault Causes: Clogged/damaged drainage pump, clogged/damaged drain pipes, condensed water tray water accumulation, humidifier water leakage.
- Solutions: Clean impurities in drainage pump, replace if damaged; unclog or replace drain pipes; clean condensed water tray and inspect drainage slope; repair humidifier leakage points.
12.1.5 Communication Failure
- Fault Causes: Damaged communication module, loose network/RS485 cables, incorrect protocol settings, network interruption.
- Solutions: Replace communication module; re-plug and fix connecting cables; verify and reset communication protocol parameters; troubleshoot network faults and restore connection.
12.2 Daily Maintenance Schedule
12.2.1 Daily Inspection
- Check unit operating status: normal temperature, humidity, pressure and current, no alarm information.
- Inspect air supply & return vents for blockages and uniform air supply.
- Check drainage system for smooth flow and no water leakage.
- Record operating data: temperature, humidity, current, voltage and fan speed, establish operation ledgers.
12.2.2 Weekly Maintenance
- Clean air filters: G4/F7 filters washable and reinstalled after drying; vacuum H13 filters for slight contamination.
- Inspect outdoor condensers: clean surface dust and debris for ventilation; check fan operation for abnormal noise.
- Inspect refrigerant pipelines for frosting, oil leakage and loose joints.
- Test humidification & heating functions to ensure normal operation and qualified parameters.
12.2.3 Monthly Maintenance
- Thoroughly clean internal unit: power off to remove dust from evaporators, air ducts and fan impellers.
- Inspect electrical systems: fasten wiring terminals, check damaged wire insulation, burnt contactors and relays.
- Calibrate temperature & humidity sensors against standard instruments to guarantee detection accuracy.
- Inspect seismic bases for loose fixing bolts and aging shockproof mats, fasten or replace timely.
12.2.4 Quarterly Maintenance
- Test compressor performance: normal operating parameters, exhaust temperature and oil level, no abnormal noise or vibration.
- Inspect expansion valves / solenoid valves for sensitive action, blockage or leakage.
- Test communication functions: normal remote monitoring, parameter setting and alarm upload to guarantee stable communication.
- Inspect heat recovery assemblies (high configuration): qualified heat exchange efficiency, unclogged and leak-free pipelines.
12.2.5 Annual Maintenance
- Full unit overhaul: disassemble core components (compressors, fans, evaporators, condensers) for cleaning, inspection, repair or replacement of damaged parts.
- Replace aging accessories: unified replacement of aged filters, sealing parts, shockproof mats and wires.
- Full system performance test: full-load operation test to detect cooling capacity, temperature & humidity control accuracy and energy consumption compliance.
- Archive maintenance records: sort annual maintenance data, fault records and repair reports to establish equipment health files.
12.3 Maintenance Precautions
- Maintenance operations must be performed by certified professional personnel, strictly following power-off, voltage test and grounding safety procedures to prevent electric shock accidents.
- Power off and shut down units before maintenance, hang “No Closing Switch” warning signs to avoid accidental startup.
- Refrigerant pipeline maintenance requires professional refrigeration engineers to prevent refrigerant leakage, environmental pollution or personnel frostbite.
- Wear safety harness for high-altitude maintenance (outdoor condensers) and take protective measures to prevent falls.
- Trial run equipment for 30 minutes post-maintenance to confirm normal operation with no faults or water leakage before restoring normal service.
13. Factory Strength & After-sales Service
13.1 Factory Strength
KITOZER brand belongs to Guangzhou La’an Intelligent System Development Co., Ltd., a high-tech enterprise integrating R&D, production, sales and service of computer room temperature control equipment. The factory is located in Guangzhou, Guangdong Province with a 20,000㎡ modern production base and annual output value exceeding 500 million RMB.
- R&D Capacity: 50-person professional R&D team with core technicians holding over 10 years of computer room air conditioner R&D experience; annual R&D investment accounts for 15% of revenue, owning over 30 invention and utility model patents, mastering core technologies including inverter control, high-efficiency heat exchange and intelligent monitoring.
- Production Capacity: Introduced internationally advanced sheet metal processing, heat exchanger production, complete machine assembly and testing production lines to realize full-process automated production; core components (compressors, fans, controllers) adopt world-famous brands (Copeland, Emerson, Schneider), strictly implementing ISO9001 quality system standards. Every unit undergoes 72-hour full-load testing before delivery to guarantee stable and reliable product quality.
- Production Scale: Annual production capacity of in-row air conditioners reaches 10,000 sets, standard models kept in stock for fast delivery of large-scale projects; customized production available with adjustable size, cooling capacity and functional modules per customer demand, customization cycle 7–15 days.
- Quality Certifications: Products pass ISO9001 Quality System Certification, ISO14001 Environmental System Certification, CE Certification and 3C Certification, complying with national computer room air conditioner industry standards and reaching international advanced quality level.
13.2 After-sales Service
KITOZER establishes a national integrated after-sales service system, adhering to the service philosophy of “Fast Response, Efficient Resolution, Full Lifecycle Support” to provide full-lifecycle services for customers:
- Service Network: 30 provincial service centers and 120 municipal service outlets nationwide covering all provinces and cities; over 500 professional after-sales engineers with strict training and assessment certification to guarantee fast customer response.
- Warranty Commitment: Full series products enjoy 3-year whole machine warranty, core components (compressors, controllers) 5-year warranty; free repair and component replacement for non-artificial damage within warranty period; lifelong technical support and maintenance service with only component cost charged after warranty.
- Response Time: 7×24h all-weather service; customer repair requests responded within 1 hour, engineers arrive on-site within 4 hours (urban areas), faults resolved within 24 hours; remote maintenance guidance for remote areas or nearby engineer dispatch for support.
- Installation & Commissioning Service: Free professional installation guidance and commissioning service; dedicated engineers follow up large projects on-site to guarantee standardized installation, qualified commissioning and normal operation.
- Training Service: Free operation and maintenance training for customers including on-site training, online training and video tutorials; training content covers equipment operation, parameter setting, daily maintenance and fault troubleshooting to ensure customer staff independent operation and maintenance.
- Remote Monitoring Service: Remote monitoring system standard for high configuration models to track real-time equipment operation and early warn faults; after-sales service center monitors equipment 24h a day to contact customers proactively upon abnormality and resolve issues in advance to avoid fault escalation.
- Spare Parts Support: 5 national spare parts warehouses with sufficient stock of core accessories (compressors, fans, controllers, filters) to realize rapid spare parts allocation during maintenance, shorten repair cycles and reduce shutdown losses.
14. Conclusion
As core temperature control equipment for high-density data centers, modular computer rooms and high heat density cabinet scenarios, KITOZER in-row air conditioners resolve pain points of traditional room-level air conditioners such as mixed cold & hot air flow, prominent local hot spots and high energy consumption, with core advantages including close-to-heat-source high-efficiency cooling, inverter energy saving & low PUE, precise temperature control & high stability, compact space-saving design and full front easy maintenance.
Covering full-scenario solutions from economical low-configuration to full-function intelligent high-configuration models, KITOZER in-row air conditioners are supported by professional R&D, production and quality control systems plus national integrated after-sales service network, delivering high-quality, reliable and cost-effective computer room temperature control products and services. We help customers build green, energy-saving, efficient and stable data center environments and drive high-quality development of the data center industry.
In the future, KITOZER will continuously increase R&D investment, optimize product performance and innovate technical solutions, keeping pace with the high-density, intelligent and green development trend of data centers to deliver superior computer room temperature control solutions and services, achieving win-win results with all customers.
15. Search Keywords, SEO & Tags
15.1 Search Keywords
- Core Keywords: Computer Room In-row Air Conditioner, Aisle Air Conditioner, KITOZER In-row Air Conditioner, High-density Computer Room Air Conditioner, Modular Computer Room Air Conditioner
- Long-tail Keywords: Air-cooled In-row Air Conditioner, Chilled Water In-row Air Conditioner, Dual-Cooling-Source In-row Air Conditioner, Computer Room Precision Air Conditioner, High Heat Density Computer Room Heat Dissipation Solution, Data Center In-row Air Conditioning Solution, Computer Room Constant Temperature & Humidity Air Conditioner, Edge Computing Room Air Conditioner, AI Computing Power Room Air Conditioner, Financial Computer Room Air Conditioner
15.2 Tags
- Product Tags: #KITOZER #InRowAirConditioner #AisleAirConditioner #ComputerRoomPrecisionAirConditioner #HighDensityComputerRoomAC
- Scenario Tags: #DataCenter #ModularComputerRoom #AIComputingRoom #FinancialComputerRoom #EdgeComputingRoom
- Technical Tags: #InverterEnergySaving #ConstantTemperatureHumidity #IntelligentMonitoring #DualCoolingSource #HeatRecovery
- Solution Tags: #ComputerRoomHeatDissipationSolution #DataCenterTemperatureControl #GreenDataCenter