KITOZER
KITOZER

KITOZER In-Row Data Center Air Conditioner Product Center Introduction

Table of Contents

(I) Product Overview

1. Product Positioning

This series of in-row air conditioners are high-precision cooling equipment specially designed for high-density data centers, modular computer rooms, communication base station machine rooms, industrial control rooms and other scenarios. As the core product of KITOZER’s data center temperature control solution, they adopt a close-to-heat-source cooling mode to solve pain points of traditional computer room air conditioners such as mixed cold and hot airflow, low cooling efficiency and severe local hotspots. They deliver stable, efficient and precise temperature control protection for IT equipment including servers, switches and UPS units, making them the preferred temperature control solution for green energy-saving renovation and new construction of modern data centers.

Airflow Schematic of In-Row Air Conditioner

2. Core Values

  • High Energy Efficiency: The in-row close cooling mode drastically shortens cold and hot airflow paths and reduces cold loss, delivering an energy saving rate of over 30% compared with traditional computer room air conditioners and effectively lowering the PUE of data centers.
  • Precise Temperature & Humidity Control: It supports high-precision temperature control of ±0.5℃ and humidity regulation of ±3% RH, rapidly responding to changes in IT equipment load, eliminating local hotspots and guaranteeing stable equipment operation.
  • Flexible Adaptation: Modular design allows single-unit capacity expansion and parallel operation. The units can be flexibly deployed according to cabinet layouts, adapting to cold/hot aisle containment and meeting cooling demands of cabinets with different power densities.
  • High Stability & Reliability: Full-metal structure plus redundant design of core components supports 7×24h non-stop operation. Multiple fault protection mechanisms reduce the risk of computer room outages.

3. Product Highlights

  • ✅ Large Wind-Area Evaporator Coil: Large-diameter high-efficiency heat exchange coils expand heat exchange area, boost cooling efficiency and cut air resistance and fan power consumption.
  • ✅ Low-Noise High-Efficiency EC Fans: DC brushless EC fans with stepless speed regulation feature a wide adjustable air volume range and low operating noise, with automatic switching upon fan failure.
  • ✅ Low-Noise Air Duct Design: Optimized internal airflow structure reduces eddy currents and air resistance to lower operation noise, while preventing cold-hot airflow short-circuit and improving cooling efficiency.
  • ✅ Full-Metal Sheet Metal Structure: High-strength cold-rolled steel plates with electrostatic plastic spraying deliver rust and corrosion resistance. The cabinet reaches IP20 protection grade for complex computer room environments.
  • ✅ Multi-Functional High-Precision Controller: Supports local touch operation and remote monitoring, real-time display of temperature/humidity, operating status and fault information, and Modbus communication protocol for integration into data center environment monitoring systems.
  • ✅ Integrated Humidification & Heating Modules: Selected models come with electrode humidifiers and electric heating modules to stabilize temperature and humidity all year round for all regions and seasons.

Performance Comparison Chart

(II) Product Classification

Classification DimensionProduct TypeApplicable Scenarios
Cooling TypeAir-Cooled In-Row Air ConditionerSmall & medium-sized data centers and modular computer rooms without cooling water supply
Water-Cooled In-Row Air ConditionerLarge-scale data centers with centralized cooling water systems
Fluorine Pump Free-Cooling In-Row Air ConditionerNew large data centers that maximize natural cold source utilization to cut energy consumption
Airflow DirectionFront Air Supply / Rear Air ReturnCold aisle containment scenarios: air supply from cold aisle side of cabinets, air return from hot aisle side
Top Air Supply / Bottom Air ReturnComputer rooms without aisle containment, requiring underfloor air supply or top air return
Power Grade12kW–25kW Compact ModelMedium & low-density computer rooms with single cabinet power density ≤5kW
30kW–60kW Standard ModelHigh-density computer rooms with single cabinet power density of 5–15kW
High-Power Model above 60kWSupercomputing centers and ultra-high-density data centers with single cabinet power density ≥15kW
Function ConfigurationBasic Cooling TypeComputer rooms requiring only temperature control
Temperature & Humidity Integrated TypeCommunication machine rooms and laboratories with simultaneous temperature and humidity control demands
Redundant Backup TypeCore financial and government computer rooms with ultra-high cooling reliability requirements

(III) Product Composition & Technical Parameters

1. Core Components

  • Cooling System: High-efficiency compressors, evaporators (large wind-area heat exchange coils), condensers, electronic expansion valves, filter driers
  • Air Supply System: Low-noise high-efficiency EC fan groups, low-resistance air ducts, air volume adjustment devices
  • Control System: High-precision operation controller, temperature & humidity sensors, fault detection modules, communication modules
  • Auxiliary Functional Modules: Electric heating assemblies, electrode humidification assemblies, condensate drainage devices
  • Structural Components: Full-metal sheet metal cabinet, mesh front/side doors, shock-absorbing base, wiring trunking

On-Site Installation Drawing

2. Technical Parameter Table of Main Models

ModelCooling Capacity (kW)Air Volume (m³/h)Power Supply SpecControl AccuracyFan TypeProtection GradeDimensions (H × W × D, mm)Remarks
KTZ-XJ12123000380V/3P/50Hz±0.5℃, ±3%RH2 EC FansIP202000×600×1100Air-cooled with humidification
KTZ-XJ25256000380V/3P/50Hz±0.5℃, ±3%RH3 EC FansIP202000×600×1100Air-cooled with heating & humidification
KTZ-XJ404010000380V/3P/50Hz±0.3℃, ±3%RH4 EC FansIP202200×600×1200Water-cooled, parallel operation supported
KTZ-XJ606015000380V/3P/50Hz±0.3℃, ±2%RH5 EC FansIP202200×800×1200Fluorine pump type with energy-saving free cooling

(IV) Core Advantages

1. Material Advantages

  • High-Strength Sheet Metal: Cabinets adopt 1.5mm–2.0mm premium cold-rolled steel plates treated with pickling, phosphating and electrostatic plastic spraying, scratch and corrosion resistant with a service life of ≥10 years.
  • High-Efficiency Heat Exchange Materials: Evaporators and condensers use inner-thread copper tubes and hydrophilic aluminum foils, boosting heat exchange efficiency by 15% vs ordinary coils with superior anti-condensation and anti-corrosion performance.
  • Low-Noise Components: EC brushless DC fan motors deliver high efficiency and long service life, operating 10–15dB quieter than traditional AC fans to meet low-noise requirements of computer rooms.

Factory Stock Units

2. Process Advantages

  • Modular Assembly Process: Modular core components simplify on-site installation, maintenance and capacity expansion to reduce long-term operation and maintenance costs.
  • Airflow Optimization via CFD Simulation: Computational Fluid Dynamics simulation optimizes internal air ducts and fan layout to eliminate eddy currents and air resistance, ensuring uniform cold air distribution and erasing local hotspots.
  • Anti-Rust & Anti-Leakage Process: Pipeline welding with continuous nitrogen protection, followed by strict pressure testing and leakage inspection before delivery to eliminate refrigerant leakage risks.

3. Customization Advantages

  • Customizable Cooling Capacity: Models with cooling capacity from 12kW to 120kW tailored to cabinet power densities.
  • Customizable Structure: Multiple airflow directions (front/top air supply, side/bottom air return) and customizable cabinet sizes and colors to fit various computer room layouts.
  • Customizable Functions: Add or remove humidification, heating, free cooling, remote monitoring and other modules based on special machine room demands.
  • Customizable Communication: Compatible with Modbus, SNMP, BACnet and other communication protocols for mainstream data center environment monitoring systems.

4. Cost Advantages

  • Energy-Saving Operation Cost Reduction: High-efficiency cooling and close cooling design cut annual power consumption significantly, lowering long-term operating expenses.
  • Low Operation & Maintenance Cost: Modular structure and high-reliability components reduce failure rates and cut maintenance and spare part procurement costs.
  • Low Renovation Cost: Flexible deployment eliminates the need for ceiling or raised floor reconstruction, saving computer room renovation expenses vs traditional air conditioners.

5. Quality Advantages

  • Core components sourced from top international brands (compressors, fans, controllers). Every unit undergoes 72-hour continuous operation testing before delivery to guarantee stable performance.
  • Redundant design of key components (dual fans, dual power supply) enables automatic switchover upon failure to avoid single-point faults causing computer room shutdowns.
  • Full-process quality control: Strict inspections at every stage from raw material procurement and assembly to factory testing to meet industry standards.

(V) Material & Process Analysis

1. Detailed Material Specifications

  • Cabinet Sheet Metal: SPCC premium cold-rolled steel plates ≥1.5mm thick with electrostatic plastic spraying coating ≥60μm thick, outstanding impact and corrosion resistance for long-term dusty and humid computer room environments.
  • Heat Exchange Coils: Inner-thread copper tubes (wall thickness ≥0.8mm) paired with anti-corrosion hydrophilic aluminum foil fins to prevent condensation corrosion and boost heat exchange efficiency.
  • Fan Assemblies: Top-tier domestic/German EC brushless DC fans with IP55 protection grade, efficiency ≥85%, 0–100% stepless speed regulation, operating noise ≤65dB(A).
  • Controller: Industrial-grade 7-inch HD touch screen with Chinese/English interface, IP54 protection grade, resistant to complex electromagnetic interference in computer rooms.

Front & Back View of Units

2. Core Process Descriptions

  • Nitrogen-Protected Welding: Nitrogen flows through pipelines during welding to prevent internal oxidation, followed by 24-hour nitrogen pressure holding testing; units pass inspection only if pressure remains unchanged to eliminate refrigerant leakage risks.
  • CFD Airflow Simulation Optimization: Fluid dynamics simulation replicates indoor airflow distribution to optimize fan layout and air duct design for full cold air coverage of cabinets and hotspot elimination.
  • Electrostatic Plastic Spraying: Fully automatic spraying assembly line delivers uniform, high-adhesion coatings that resist scratching, fading and rusting over long-term use.
  • Aging Testing Process: Every unit undergoes 72-hour continuous operation aging tests simulating various load and temperature-humidity conditions to verify stable performance and fault protection functions.

3. Safety Certifications

  • Compliant with GB/T 19413 Unitary Air Conditioners for Computer and Data Processing Rooms industry standard.
  • CE and 3C certifications available upon request; core components hold UL and TUV certifications for full safety compliance.
  • Third-party performance testing available, with complete factory inspection reports and certificates supplied.

(VI) Spot Goods Details

Production Workshop Inventory

  • Mainstream models (12kW, 25kW, 40kW air-cooled) are kept in ample stock for fast delivery.
  • Custom models have a production lead time of 7–15 working days, adjusted according to order quantity and configuration requirements for on-time delivery.
  • All in-stock units complete factory testing prior to shipment; on-site inspection and installation guidance are supported.

(VII) OEM Processing & Confidentiality

  • OEM/ODM custom processing services available: Custom production based on client brand, technical parameters and appearance requirements, with full confidentiality of client technical solutions and order information.
  • Processing scope: Complete unit customization, core component assembly, appearance branding, functional module customization, catering to brand owners, system integrators and engineering contractors.
  • Confidentiality Commitment: Confidentiality agreements signed, exclusive production files established for each client, prohibiting disclosure of client technical parameters, order data and brand logos to secure commercial information.

(VIII) Product SKU Attributes

SKU CodeProduct NameCooling CapacityPower Supply SpecFan QuantityFunction ConfigurationApplicable Scenarios
KTZ-XJ12-F-LAir-Cooled In-Row Air Conditioner12kW380V/3P/50Hz2Basic CoolingSmall Modular Computer Rooms
KTZ-XJ25-F-HAir-Cooled In-Row Air Conditioner25kW380V/3P/50Hz3Cooling + Heating + HumidificationCommunication Base Station Machine Rooms
KTZ-XJ40-S-BWater-Cooled In-Row Air Conditioner40kW380V/3P/50Hz4Cooling + Remote MonitoringMedium & Large Data Centers
KTZ-XJ60-Z-NFluorine Pump In-Row Air Conditioner60kW380V/3P/50Hz5Cooling + Free CoolingLarge-Scale Data Centers

(IX) Full Technical Parameter Table

(Identical to the table in Section III, available for repeated display for customer reference)

(X) Application Scenarios

  • Data Center Machine Rooms: Cold/hot aisle containment solutions to resolve high-density cabinet cooling challenges and reduce data center PUE.
  • Modular Computer Rooms: Adaptable to containerized and micro-module data centers with fast deployment and flexible capacity expansion.
  • Communication Base Station Machine Rooms: Deliver stable year-round temperature & humidity for communication equipment and support unattended operation.
  • Industrial Control Machine Rooms: Factory automation and power control rooms, stable operation in harsh industrial environments to protect equipment.
  • Financial & Government Core Machine Rooms: High reliability and precision temperature control for core business systems.
  • Laboratory & Medical Equipment Rooms: Strict temperature & humidity control to prevent damage to precision lab and medical equipment.

(XI) Customization Service Details

1. Customization Scope

  • Cooling Capacity Customization: 12kW–120kW power grades matching single cabinet power density of 1–20kW.
  • Airflow Direction Customization: Front supply/rear return, top supply/bottom return, side supply/side return and other airflow modes.
  • Functional Module Customization: Add or remove humidification, heating, free cooling, dual power supply, remote monitoring, fire linkage and other functions.
  • Appearance & Structure Customization: Cabinet dimensions, colors, door styles and handle positions fully customizable.
  • Communication Protocol Customization: Compatible with Modbus, SNMP, BACnet, HTTP and other protocols for diverse environment monitoring systems.

2. Customization Process

  1. Demand Communication: Align with clients on site conditions, cabinet layout, power density and functional requirements.
  2. Solution Design: Technical team develops customized design plans and technical parameter sheets per client demands.
  3. Solution Confirmation: Client reviews and approves technical specs, configuration and quotation, then signs customization contract.
  4. Production & Manufacturing: Production scheduled per custom design, with regular progress updates to clients.
  5. Factory Testing: Post-production performance and aging tests conducted, with inspection reports issued.
  6. Shipment & Delivery: Shockproof moisture-proof packaging for shipment, with installation manuals and technical support provided to assist on-site commissioning.

3. Customization Advantages

  • Professional R&D team develops personalized solutions matching on-site operating conditions without extra computer room reconstruction.
  • Flexible modular combination allows clients to add/remove functions as needed to cut unnecessary costs and improve cost performance.
  • Fast response to custom demands: standard custom orders delivered within 7–15 working days, priority scheduling available for urgent orders.
  • End-to-end one-on-one technical support covering solution design through on-site commissioning to guarantee perfect on-site adaptation.

(XII) Project Reference Cases

1. Cooperative Clients

  • Multiple domestic telecom operator base station projects
  • Financial institution core data center renovation projects
  • Government cloud platform modular computer room new construction projects
  • Industrial enterprise automation control room temperature control projects

2. Case Highlights

  • Telecom Operator Data Center: KITOZER 40kW water-cooled in-row air conditioners paired with cold aisle containment cut data center PUE from 1.8 to 1.3, delivering 35% annual power savings with zero equipment failures.
  • Government Modular Computer Room: 25kW air-cooled in-row air conditioners with dual-unit redundant backup achieve ±0.3℃ temperature control precision, ensuring uninterrupted stable operation of government systems and winning high client recognition.
  • Industrial Control Room: Custom units with heating and humidification adapt to low-temperature high-humidity northern environments, maintaining consistent year-round temperature & humidity and eliminating equipment damage caused by poor environmental conditions.

(XIII) Procurement Service Guarantees

1. Supply Guarantee

  • Mainstream models kept in stock for fast bulk order delivery.
  • Exclusive production schedules arranged for custom orders to ensure on-time delivery per contract and avoid project delays.

2. Quality Guarantee

  • Full factory inspection reports, certificates and technical manuals supplied with every unit.
  • Traceable brand-sourced core components, no counterfeit spare parts used.

3. Logistics Guarantee

  • Professional logistics partners with shockproof moisture-proof packaging to prevent damage during transit.
  • Door-to-door delivery available; dedicated staff accompany large shipments for on-site inspection assistance.

4. After-Sales Guarantee

  • 1-year free warranty: free repair and component replacement for non-human-induced faults within the warranty period.
  • Lifetime technical support and maintenance services; only cost charged for spare parts post-warranty.
  • On-site installation, commissioning and fault repair available in multiple regions nationwide, with response time ≤24 hours.

5. Invoice Guarantee

  • 13% VAT special invoices issued for corporate expense reimbursement and tax deduction.
  • Standardized invoicing process; invoices shipped with goods or dispatched separately per client request for smooth financial settlement.

(XIV) Conversion Modules

1. Call-to-Action Buttons

  • 【Inquire Now】Get customized data center cooling solutions and quotations
  • 【Request Sample】Book on-site test unit demonstration
  • 【View Cases】Learn more data center temperature control project references

2. Contact Information

  • Sales Hotline: +86 13538869979, +86 13538869979
  • Official Website: gdlain.com
  • WeChat Consultation: Scan QR code to add sales consultant for exclusive service

3. Address

No.5 Huashan Road, Shilou Town, Panyu District, Guangzhou City, Zhongrun Industrial Park Chaotian Zone

4. Preferential Reminders

  • Tiered volume discounts available for bulk purchases; consult sales consultants for detailed pricing.
  • Annual framework cooperation agreements grant priority production scheduling, fast delivery and exclusive after-sales support.

5. Frequently Asked Questions (FAQ)

  1. What advantages do in-row air conditioners have over traditional computer room air conditioners? Answer: In-row air conditioners adopt close cooling to minimize cold loss and boost cooling efficiency, lowering data center PUE. Modular design enables flexible deployment for high-density cabinets, delivers precise temperature & humidity control and eliminates local hotspots.
  2. What communication protocols do the units support? Can they connect to data center environment monitoring systems? Answer: They support mainstream protocols including Modbus, SNMP and BACnet, enabling seamless integration with nearly all standard data center environment monitoring systems for remote centralized management.
  3. How long is the warranty period? How to handle equipment faults after failure? Answer: 1-year full warranty; free repair and component replacement for non-human-induced faults within the warranty term. Lifetime technical support and maintenance are available post-warranty, with nationwide on-site service response time ≤24 hours.
  4. Can you customize products tailored to my computer room conditions? Answer: Full customization service covers cooling capacity, airflow direction, functional modules and cabinet appearance. Our technical team designs exclusive solutions matching your cabinet layout and operational requirements.

(XV) Equipment Faults & Maintenance Guidelines

1. Common Faults & Troubleshooting

Fault PhenomenonPotential CausesSolutions
Unit fails to startPower failure, controller breakdown, protective device activationInspect power connection and voltage, restart controller, check fault codes for troubleshooting
Poor cooling performanceClogged filter screen, faulty fan, refrigerant leakage, scaled coilsClean or replace filter screens, inspect fan operation, test refrigerant pressure, flush heat exchange coils
Inaccurate temperature & humidity controlMalfunctioning sensors, incorrect controller parameter settingsCalibrate or replace sensors, verify and adjust controller parameters
Excessive operating noiseLoose fan assembly, foreign objects in air ducts, worn componentsFasten fan components, clear duct debris, replace worn spare parts

2. Routine Maintenance Specifications

  • Monthly Maintenance: Inspect operating status and temperature-humidity readings, clean air filter screens, check fan noise and vibration.
  • Quarterly Maintenance: Test refrigerant pipeline pressure, flush evaporator and condenser coils, fasten wiring terminals, verify fault protection functions.
  • Annual Maintenance: Full inspection of core components (compressors, fans, controllers), replace aged parts, conduct full system performance testing and refrigerant leakage inspection.
  • Long-Term Shutdown Maintenance: Clean filter screens and coils before powering off, cut power supply, drain condensate water, apply dustproof moisture-proof protection, and power on periodically for functional inspection.

(XVI) Factory Strength & After-Sales Service

1. Factory Strength

  • Self-owned modern production workshop equipped with automatic sheet metal production lines, welding equipment and aging test benches with annual output exceeding 1,000 units.
  • Professional R&D and technical team with independent design, development and customization capacity to rapidly respond to personalized client demands.
  • Strict quality management system covering raw material procurement through factory testing, with full-process inspection to guarantee stable unit performance.

2. After-Sales Service

  • Dedicated one-on-one technical consultants provide full-cycle support covering solution design, on-site installation and long-term maintenance.
  • Service outlets across multiple regions nationwide offering on-site installation, commissioning, fault repair and regular inspection services.
  • Regular maintenance guidance and technical training provided to clients to improve internal equipment operation capabilities.

(XVII) Conclusion

KITOZER LAIN in-row data center air conditioners stand out with high energy efficiency, precise temperature control, flexible adaptation and reliable performance, emerging as the preferred temperature control solution for data centers and modular machine rooms. Centered on client demands, we deliver end-to-end services including solution design, custom production and after-sales maintenance to safeguard your IT equipment and support the construction of eco-friendly, high-efficiency and stable modern data centers.

For more product details, custom solutions or quotations, please contact us at any time — we are ready to provide dedicated professional service for you.

(XVIII) SEO Optimization Keyword System

1. Core Primary Keywords

In-row data center air conditioner, KITOZER in-row air conditioner, data center in-row cooling unit

2. High-Conversion Long-Tail Keywords

In-row air conditioner manufacturer, customized in-row air conditioner, modular data center in-row AC, high-density cabinet in-row cooling unit, energy-saving retrofitting of data center in-row air conditioners

3. Industry Traffic Keywords

Data center precision air conditioner, data center temperature control solution, cold aisle air conditioner, close-proximity cooling unit for computer rooms, industrial-grade data center air conditioner

4. Brand Exclusive Keywords

KITOZER LAIN in-row air conditioner, LAIN data center in-row cooling unit, KITOZER computer room air conditioner

5. Search Suggestion & Related Search Keywords

In-row air conditioner price, in-row air conditioner installation plan, top brands of data center in-row AC, difference between in-row air conditioner and traditional precision AC, in-row air conditioner selection guide for data centers

6. Core Page Optimization Tags

  • Title Tag: KITOZER In-Row Data Center Air Conditioner Manufacturer | Custom Modular Computer Room Cooling Units – LAIN Intelligent
  • Meta Keywords: In-row data center air conditioner, KITOZER in-row air conditioner, modular data center cooling unit, precision air conditioner manufacturer
  • Meta Description: LAIN Intelligent, professional manufacturer of KITOZER in-row air conditioners, provides high-efficiency precise cooling custom in-row AC for data centers and modular computer rooms. OEM processing available, reliable quality and comprehensive after-sales service.
  • H1 Tag: KITOZER In-Row Air Conditioner – High-Efficiency Temperature Control Solution for Data Centers
  • H2 Tags: Product Overview, Product Classification, Core Advantages, Application Scenarios, Customization Services, Procurement Guarantees (consistent with chapter titles above)

7. Internal Link Anchor Text Optimization

  • Core Anchor Text: In-row data center air conditioner, KITOZER in-row air conditioner
  • Long-Tail Anchor Text: Data center in-row cooling unit, modular computer room in-row air conditioner, customized in-row air conditioner, in-row air conditioner manufacturer
  • Related Anchor Text: Data center precision air conditioner, data center temperature control solution, cold aisle containment air conditioner, close-proximity cooling system for computer rooms
Scroll to Top