KITOZER Indirect Evaporative Cooler 100kW For Dry Climate Data Center

Product Overview

KITOZER 100kW indirect evaporative cooler (IEC) uses evaporation of water on a secondary air stream to cool a primary air stream without adding humidity to the data hall. The primary air passes through heat-exchanger tubes, while water is sprayed on the outside; evaporation cools the tubes, and the secondary air carries the heat and moisture outside. The primary air delivered to the IT space remains dry and clean, decoupling cooling from humidification. In dry climates, IEC can provide full cooling free of mechanical compressors for most of the year, pushing PUE below 1.2.

Technical Specifications

Cooling capacity 100kW at 35 degrees C dry bulb and 20 degrees C wet bulb, primary airflow 30,000 cubic meters per hour, secondary airflow 36,000 cubic meters per hour, water consumption 25 liters per hour at design, EC fans 5kW total, water circulation pump 0.75kW, supply voltage 380V three phase, dimensions 2,500 millimeters wide by 1,800 millimeters deep by 2,000 millimeters high, weight about 900kg, aluminum heat exchanger tubes, G4 filtration on primary side, Modbus TCP, SNMP, CE certified.

Application Scenarios

Indirect evaporative coolers are deployed in dry climates such as northern China, the western United States, the Middle East, and inland Australia. They suit hyperscale data centers, colocation halls, and industrial process cooling where water is available but electricity is expensive. The unit can be the primary cooling stage with a mechanical chiller as backup for extreme humidity days.

Advantages and Features

Dry primary air avoids over-humidifying IT spaces. No compressor in indirect evaporative mode cuts energy by 70 percent compared with DX. EC fans modulate with load. Water treatment and blow-down controls prevent scaling. The unit integrates with a mechanical cooling backup for rare humid spikes.

Installation and Maintenance Recommendations

Connect water supply with a water meter and drain. Install a water treatment system appropriate to local water hardness. Locate the unit outdoors away from dust sources. Commission by measuring primary air temperature drop. Maintenance includes weekly water quality check, monthly pump strainer cleaning, annual tube inspection, and bi-annual fan bearing lubrication. Keep spare spray nozzles on site.

Price

From $38,800 per unit. Contact KITOZER for climate-specific performance data.