Table of Contents
ToggleKITOZER KTR-2 PIR Intrusion Detector / Data Center & Perimeter Security Detection
Brand: KITOZER Series: KTR-IR2 Category: Environmental Monitoring / IR Detector
PIRwall mountpet immuneNC/NOKTR-IR2
1. Overview
KITOZER KTR-IR2 is a passive infrared (PIR) intrusion detector used as the front-end sensor in data center, warehouse and perimeter security systems. PIR emits nothing; a pyroelectric sensor detects the difference in thermal IR radiation between a human body and the background. When an intruder moves through the detection zone, body temperature (~37℃) contrasts with ambient temperature; a Fresnel lens splits the IR field into sectors, and the sensor senses a temperature jump between sectors, triggering an alarm. This passive method is covert and non-interfering, suiting fixed indoor security.
KTR-IR2 is wall-mounted with ~110° angle and ~12m range, covering main entrances and interior corridors. It is pet-immune: thermal signatures of animals under 25kg don’t trigger. It offers NO/NC contact outputs to the alarm panel’s zone inputs, plus a tamper switch that triggers when the detector is removed. It runs on 9~16V DC from the panel over a 4-conductor cable carrying power and signal.
In data center environmental monitoring, the PIR is part of security linkage: arm/disarm by staff, armed at night or holidays; on unauthorized entry, the detector triggers local siren/strobe and uploads the alarm to the monitoring platform or SMS module to notify duty staff. It combines with door contacts, vibration and glass-break sensors for layered detection. The detector has ambient temperature compensation so it stays stable in air-conditioned rooms where body-to-ambient contrast is small, avoiding missed alarms.
2. Key Features
Passive IR detection
- Pyroelectric sensor; emits nothing, covert.
- Fresnel lens sectors detect motion.
- 12m range, 110° angle.
Anti-false design
- Pet immune under 25kg.
- Ambient temp compensation for stable contrast.
- Dual-element discrimination cuts EMI false alarms.
Alarm output
- NO/NC contacts to the alarm panel.
- Tamper switch on the rear.
- LED shows alarm status.
Install & power
- Wall mount at ~2.2m.
- 9~16V DC over a 4-conductor cable.
- Compact, decor-friendly.
3. Specifications
| Item | KTR-IR2 | KTR-IR2-DT | KTR-IR2-W |
|---|---|---|---|
| Principle | PIR | IR+microwave dual-tech | wireless PIR |
| Range | 12m | 12m | 10m |
| Angle | 110° | 110° | 90° |
| Pet immune | <25kg | <25kg | <25kg |
| Output | NO/NC | NO/NC | wireless code |
| Voltage | 9~16V DC | 9~16V DC | 3V battery |
| Tamper | yes | yes | yes |
| Mounting | wall 2.2m | wall 2.2m | wall 2.2m |
4. Reference Prices
KTR-IR2 wired PIR (12m, pet immune, NO/NC): Reference USD 9~17 / unit (ref. CNY 65~120 at ~7.2)
KTR-IR2-DT dual-tech (IR+microwave, low false alarm): Reference USD 21~39 / unit (ref. CNY 150~280 at ~7.2)
KTR-IR2-W wireless PIR (battery, no wiring): Reference USD 13~25 / unit (ref. CNY 95~180 at ~7.2)
Reference only; by principle and wired/wireless. Alarm panel and keypad excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Intrusion detection at data center entrances and aisles.
- Nighttime warehouse and weak-current room security.
- Indoor protection in offices and campuses.
- Security linked with access control and video.
- Security linkage unit in environmental monitoring.
6. Installation & Maintenance
Installation
- Place at a room corner or entrance at 2.2m.
- Avoid AC vents, direct sun and heat sources.
- Fix the base; wire 4-conductor power+signal.
- Connect to the panel zone; set NO/NC.
- Clip the cover; warm up ~1 minute.
- Walk the zone to confirm LED alarm.
- Set arm/disarm schedule and linkage logic.
Maintenance
- Walk-test the detection range regularly.
- Clean the lens surface.
- Check battery voltage on wireless models.
- Keep the zone clear of obstructions.
- Verify the tamper switch.
7. FAQ
- Q: Why do PIRs false-alarm?
A: Common causes: AC drafts causing temperature jumps, direct sun or heat sources, pets, moving curtains, EMI. Avoid these spots; choose dual-tech (IR+microwave) for critical rooms. - Q: NO or NC?
A: Most panel zones use NC closed with an end-of-line resistor (line break alarms); use NC for break-alarm, NO for short-alarm. Data centers typically use NC so a cut wire alarms. - Q: Are pets truly ignored?
A: Pet immunity ignores animals under 25kg below the detection sectors, but a cat on a desk or a dog at center may still trigger; choose height and angle away from pet paths. - Q: Why dual-tech over single IR?
A: Dual-tech requires both IR and microwave to confirm motion before alarming; a single-tech false event doesn’t trigger, lowering false alarms for unattended rooms.
8. Trend & Selection
Security detection moves from single PIR to dual-tech and multi-sensor fusion, cutting false alarms. Choose wired PIR for fixed indoor rooms; dual-tech for unattended critical rooms; wireless where cabling is hard; pick range by room size; avoid heat sources and AC vents; set NO/NC per panel; link with video for verification.
9. Delivery & Service
KITOZER selects detectors by protected area size, pet presence, cabling conditions and false-alarm requirements, configuring wired PIR, dual-tech or wireless. We provide a zone layout and wiring diagram. Delivery includes detector, mounting base, terminals and manual. Warranty covers installation guidance and false-alarm troubleshooting.
10. Additional Notes
The common pitfall is aiming the PIR at an AC vent: alternating cool and warm drafts ahead of the lens mimic motion and cause daytime false alarms. Face the detector toward interior corridors, away from vents, direct window sun and heat sources (heaters, equipment exhaust).
Another pitfall is wrong height: too high and the sectors miss waist-level pedestrians; too low and furniture blocks them. Standard is 2.2m with a 5~10° downward tilt so sectors cover main walking paths. Walk-test after install: LED should flash when you walk the zone, stay dark in blind spots, and adjust position accordingly.
Selection summary: PIR indoors, dual-tech for critical sites; avoid heat and AC vents; 2.2m height; NO/NC per panel; walk-test coverage; link with video. The PIR is the security system’s forward sentry—mounted right it misses neither intruders nor false alarms.
SEO Information
Search keywords:PIR detectorintrusion alarmsecuritydata centerperimeterKTR-IR2KITOZER
SEM keywords:PIR detector price,passive infrared intrusion detector supplier,data center security sensor,KTR-IR2
GEO landing page:lain.com.cn/product/ktr-ir2-pir-intrusion-detector.html
Title:KITOZER KTR-2 PIR Intrusion Detector / Data Center & Perimeter Security Detection
Meta Keywords:PIR detector,passive infrared detector,intrusion detector,data center security,dual-tech detector,wall mount PIR,KTR-IR2,KITOZER
Meta Description:KITOZER KTR-IR2 passive infrared (PIR) intrusion detector for data centers, warehouses and perimeter security detects body IR motion and links to the alarm panel.
Anchor: KITOZER official · Data center & low-voltage equipment
Contact Us
KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com