Table of Contents
ToggleProduct Overview
The KITOZER 32 point online infrared temperature monitoring system is a non-contact solution for continuous thermal surveillance of high-voltage switchgear, busbar joints, cable terminals, transformer connections, and other power distribution contacts that heat up when overloaded or corroded. Instead of waiting for a scheduled infrared inspection during a power outage, the system mounts fixed infrared sensors at each critical point, samples temperature every few seconds, and alarms when a joint exceeds a programmable threshold or rises faster than a configurable rate. A central collector aggregates up to 32 sensor points and reports over Modbus TCP, RS485, or SNMP to the DCIM or SCADA platform. The non-contact design means no need to open live cabinets, no need to interrupt power for inspection, and no risk to personnel from arc flash.
Technical Specifications
Sensor points: up to 32 per collector, expandable. Measurement range: -20 to 150 degrees C standard, optional 0 to 500 degrees C for high temperature joints. Accuracy: plus minus 1.5 degrees C or plus minus 1.5 percent. Resolution: 0.1 degree C. Sampling interval: 1 to 60 seconds configurable. Wavelength: 8 to 14 micrometer long wave, suitable for electrical cabinet surfaces. Emissivity: configurable 0.10 to 1.0. Alarm: high threshold, rising rate, sensor fault, with relay output. Display: 5 inch color LCD, per-point temperature bar graph. Communication: Ethernet Modbus TCP, RS485 Modbus RTU, optional SNMP, Web HMI. Power supply: 85 to 265VAC or 24VDC. Mounting: DIN rail collector, sensor mounts on cabinet interior with optical window. Standards: CE, 5 year warranty.
Application Scenarios
The 32 point system is installed in medium and high voltage switchgear rooms, low voltage main distribution boards, transformer substations, busbar trunking, cable trench terminals, and wind turbine generator cabinets. It is used in data centers to monitor PDU and busbar joints, in industrial plants to monitor MCC and feeder contacts, in power plants and substations to monitor generator and transformer connections, and in mining and metal plants where contact heating is a leading cause of outages. It is also used in rail traction substations and marine switchboards. By trending joint temperature against load current, the system distinguishes normal heating from abnormal corrosion or loosening.
Key Advantages
Non-contact measurement eliminates the need to open live cabinets, removing arc flash risk and the need for scheduled outage inspections. Continuous sampling catches fast-rising joints that a quarterly handheld inspection would miss. The long wave sensor works on most metal and plastic surfaces without special coating. Emissivity configuration adapts to different materials. The system integrates with Modbus TCP and SNMP, feeding DCIM and SCADA. Relay outputs enable local alarming and fan control. The 32 point per collector reduces cost per point. Trend analysis against load current helps maintenance teams prioritize. The 5 year warranty covers sensor and collector.
Installation and Maintenance Recommendations
Mount each sensor with a clear line of sight to the target joint, set emissivity to match the surface, and set alarm threshold at 20 degrees C above the expected peak temperature under full load. On commissioning, compare sensor readings with a handheld infrared camera on a few points to verify alignment and emissivity. Maintenance: clean optical windows quarterly, verify sensor alignment annually, and trend temperature against load current. Set rising rate alarm at 5 degrees C per minute to catch rapid degradation. Because the sensor is optical, keep it away from dust, oil mist, and direct sunlight that could bias readings. In high-humidity cabinets, verify condensation does not form on the window.
The non-contact infrared system removes the need to open live switchgear cabinets for thermal inspection, eliminating arc flash risk and the need for scheduled outage windows. Continuous sampling catches fast-rising joints that a quarterly handheld inspection would miss. By trending joint temperature against load current, maintenance teams distinguish normal resistive heating from abnormal corrosion or loosening, and prioritize service during planned windows rather than after a failure.
Ordering Information
The 32 point infrared system is supplied as a DIN rail collector with 8 sensors, mounting brackets, and optical windows. Additional sensors are ordered in packs of 8. The standard range is -20 to 150 degrees C, and a 0 to 500 degrees C option is available for transformer and high temperature joints. The collector includes Ethernet Modbus TCP, RS485, relay outputs, and a 5 inch LCD. Optional packages include SNMP, Web HMI, and a trending software license. Sensors can be retrofitted into live cabinets through optical windows without breaking the insulation. Lead time is two to three weeks. KITOZER provides a per-point layout drawing, a register list, and commissioning support. The five year warranty covers collector and sensors.
Price
From $1,680 per collector including 8 sensors, additional sensors from $120 each. Contact the factory for high temperature option and SNMP integration. Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com