KITOZER
KITOZER

KITOZER Infrared Temperature Sensor: Industrial Non Contact

Product Overview

KITOZER industrial infrared temperature sensor is a compact fixed-installation pyrometer that measures surface temperature from a distance without physical contact, outputting the result as a 4-20mA analog signal or Modbus RTU. It is used to monitor hot spots on electrical busbars, bearings, oven walls, conveyor belts, and process equipment where contact sensors cannot be installed. The sensor has a rugged stainless steel housing, adjustable emissivity, and a laser sight for accurate aiming. A wide temperature range from minus 20C to plus 500C covers most industrial and electrical monitoring applications.

Non-contact measurement is essential in live electrical equipment, where a contact thermocouple would require shutting down the panel and risking contact with busbars. The IR sensor mounts outside the panel and looks through a small window at the busbar joint, reporting temperature continuously to the PLC. It is also used on rotating equipment where a contact sensor would wear out, and on moving conveyor belts where physical contact is impossible. The 4-20mA signal is immune to electrical noise and runs reliably over hundreds of meters in industrial plants.

Technical Specifications

Temperature range minus 20C to plus 500C, optical resolution 30:1, response time 150ms, spectral range 8um to 14um, emissivity adjustable 0.10 to 1.00. Output 4-20mA or RS485 Modbus RTU. Accuracy plus or minus 1 percent of reading or plus or minus 2C. Repeatability plus or minus 0.5 percent. Power supply 12V to 24VDC. Housing stainless steel IP65, dimensions 45mm diameter by 120mm long. Operating temperature 0C to plus 70C. Laser sight class 2. CE, KITOZER brand, two year warranty.

Application Scenarios

This sensor is installed above electrical switchgear busbars to monitor contact temperature without opening the panel, on motor bearings to detect friction heating, on furnace walls for refractory health monitoring, and on conveyor pulleys for bearing overheat protection. It is also used in food processing, plastics extrusion, and oven lines where contact probes would contaminate the product or wear out quickly. The 4-20mA output connects directly to PLC analog inputs, and the Modbus option feeds SCADA with temperature plus emissivity and signal strength.

Additional installations include paper mill drying cylinders, steel mill reheating furnaces, cement kiln surface monitoring, and electrical panel busbar joint monitoring. In each case, the target is either live, moving, too hot, or too remote for a contact thermocouple. The sensor is also used in HVAC duct temperature monitoring where a contact probe would be damaged by airflow. The stainless steel IP65 housing withstands washdown in food and pharmaceutical plants.

Advantages and Features

Non-contact measurement means no sensor wear, no drilling, and no electrical contact with live parts, which is especially valuable in high-voltage switchgear. The adjustable emissivity allows the sensor to be tuned to painted metal, polished metal, or plastic surfaces. The 30:1 optical ratio means the sensor can be mounted 1 meter away from a 33mm target, giving installers flexibility in crowded panels. The stainless steel IP65 housing withstands washdown and dusty factory environments. The laser sight simplifies aiming during installation and maintenance.

The 150ms response time captures fast temperature changes on motor starts and process transients. The 4-20mA output is supported by every PLC and DCS on the market. The Modbus option provides additional diagnostics such as signal strength and internal sensor temperature. The wide 12V to 24VDC supply range suits standard industrial control power. The two year warranty covers the sensor and its electronics.

Installation and Maintenance

Mount the sensor on a fixed bracket with a clear line of sight to the target. Set the emissivity to match the surface material using the configuration button or Modbus command. Use the laser sight to align the spot. Wire the 4-20mA output to the PLC analog input using shielded cable. Periodically clean the optical window with a soft cloth and lens cleaner, because dust buildup shifts the reading. Recalibrate annually against a contact reference thermocouple. Keep the cable away from high-voltage busbars to avoid interference.

During installation, ensure the target fills the measurement spot at the chosen distance, according to the 30:1 optical ratio. For polished metal surfaces, set emissivity to 0.3 or use high-emissivity paint on the target. Ground the shield of the 4-20mA cable at the PLC end. If the reading drifts, clean the window first. The laser sight should be used only during setup, not continuously, to extend laser life. The sensor can be ordered with an optional air-purge collar for dusty environments, which keeps the optical window clean in cement, woodworking, or metal grinding plants. A mounting bracket with adjustable angle is included, allowing fine aiming after installation.

Price

From $120/pc. Contact +86 13922289957 for infrared sensor pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart